Do you have a question about the Confiscope g20 and is the answer not in the manual?
Questions and answers
Summary of Contents for GenBody Confiscope g20
Page 1
User Manual may be reproduced in whole or in part without the prior written permission of GenBody Inc. The information and specifications in this User Manual are subject to change without notice.
Page 2
APPENDIX EXPLANATION OF LABEL SYMBOLS GenBody Inc. Page 2 / 28...
Page 3
Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. GenBody Inc. Page 3 / 28...
Page 4
Son fonctionnement est soumis aux deux conditions suivantes: (1) Cet appareil ne doit pas provoquer d'interferences. (2) Cet appareil doit accepter toute interference, y compris les interferences qui peuvent provoquer un fonctionnement indesirable de l'appareil. GenBody Inc. Page 4 / 28...
4.1 Start the Test 4.2 Reading 4.3 Test Result 5. Data Management 5.1 Test Records 5.2 USB Backup 5.3 Delete 6. Settings 6.1 General Setup 6.1.1 Brightness 6.1.2 Date & Time 6.1.3 Key Sound GenBody Inc. Page 5 / 28...
Page 6
6.1.4 Battery Alarm 6.1.5 Incubation Alarm 6.1.6 Equipment Reset 6.1.7 Sleep Timer 6.2 Device & Update 7. Cleaning 8. Trouble Shooting 9. Other Information 9.1 System Specification 9.2 System Characteristics 9.3 Product Service GenBody Inc. Page 6 / 28...
1.1.3 Do not disassemble, repair or modify the machine without any permission. 1.1.4 GenBody is not responsible for malfunctions and damage to the product caused by irregular operation that is not mentioned in this manual. 1.2 Precautions for Installation the Product 1.2.1 Do not install in an unsafe place.
1.5.3 Store the product on a flat surface and do not allow it to be affected by impact or vibration. 1.5.4 Usage Temperature: +10℃ ~ +30℃, <70% RH GenBody Inc. Page 8 / 28...
The converted digital signal is displayed to the user so that it can be judged or numerically confirmed. 2.3 Product Components GenBody Inc. Page 9 / 28...
3.1 Powering on the system Press the power button on the right side of the machine for 2-3 seconds to boot. The screen during booting and the main screen after completion are as follows: GenBody Inc. Page 10 / 28...
Press the power button for 2-3 seconds to turn off. If the power button fails due to an error in the machine, you can turn off the device by pressing Forced Power off switch located on the right side of the device. GenBody Inc. Page 11 / 28...
Page 12
If RFID tags attached to the product are damaged, accurate recognition may not be possible. Once RFID is recognized normally, it automatically navigates to the test window and verify the item information you want to check is correct. GenBody Inc. Page 12 / 28...
Page 13
Latest Lot information shows at the top of the display. It can save up to 20 items and old items will be deleted automatically. 4.2 Reading GenBody Inc. Page 13 / 28...
Page 14
Please be careful not to overflow reagent when filling the cartridge outside the tray. 4.3 Test Result When the analysis is complete, the result screen appears with a beep sound as shown below. GenBody Inc. Page 14 / 28...
Page 15
③ If the band in the cartridge is not illuminated due to the use of the wrong sample, Invalid status may appear and refer to the cartridge’s manual for re- examination. The test results are automatically saved and can be printed if an external printer is connected. GenBody Inc. Page 15 / 28...
Page 16
If you have more than one exam history, it is arranged in the latest order and many results can be viewed using the up/down buttons. Selecting each result using the up/down buttons will switch to the Detailed Results window to view and print or delete the detailed results. GenBody Inc. Page 16 / 28...
Page 17
Make sure you have enough USB memory space and do not disconnect it during backup. Some manufacturers or models’ USB memory cannot be recognized. Please ensure that the backup is successfully done before you delete the data. GenBody Inc. Page 17 / 28...
Page 18
Deleted data cannot be retrieved. Please check before you proceed. 6. Settings User can set preferences and system check and updates. If you select Settings on the main menu, a screen for selecting General Setup, Calibration Setup, Device & Update will appear. GenBody Inc. Page 18 / 28...
Page 19
Equipment Reset Sleep Timer Calibration Setup Calibration Setup Serial Number of device and version check Device & Update Update 6.1 General Setup User can change and apply the settings by entering General Setup. 6.1.1 Brightness GenBody Inc. Page 19 / 28...
Page 20
If the test is performed with unadjusted date and time, it will be reflected to test result and test record. Please do check the current time and date periodically because the results and lot history management may fail due to the wrong implementation of time and date. GenBody Inc. Page 20 / 28...
Page 21
By entering the Incubation Alarm setting, user can adjust the loudness of incubation complete sound effect by pressing the up/down buttons. Press and hold the Select button to return to the General Settings screen. GenBody Inc. Page 21 / 28...
Page 22
6.1.7 Sleep Timer User can adjust or disable the device's sleep mode entry time by pressing the up/down buttons by entering Sleep Timer setting. Press and hold the Select GenBody Inc. Page 22 / 28...
Page 23
The update starts with a beep sound, and when the update is it is completed, it will beep again and power off. After rebooting, you can check for updated versions on the Device & Update screen. GenBody Inc. Page 23 / 28...
1. Check if RFID tags attached to item boxes are broken. reading failure. 2. Please contact the manufacturer if it recurs even after reboot. In the event of Invalid 1. Check if the test was carried out correctly according to GenBody Inc. Page 24 / 28...
Print is available by "Data Management Tool (PC)“ or Print External Thermal Printer. It cannot be printed directly from the device. It can be implemented by requirement (HL7 protocol) LIS/HIS - It is supported by "Data Management Tool (PC)“ only. GenBody Inc. Page 26 / 28...
10.3 Product Service GenBody Inc. 3-18, Eopseong 2-gil, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Republic of Korea TEL: +82-41-523-8993 Please contact your dealer for service. GenBody Inc. Page 27 / 28...
Need help?
Do you have a question about the Confiscope g20 and is the answer not in the manual?
Questions and answers