Introduction Thank you for purchasing the YA-MAN product. • Please read this User’s Manual carefully for information on how to use the device properly and safely. • After reading the contents hereof, be sure to keep this User’s Manual in an accessible location. •...
Page 3
DANGER (regarding use and storage) ● The following individuals should not use the device. Use of the device could cause electronic medical devices to malfunction. Prohibition ◆ Do not use in conjunction with any medical electronic equipment, including: pacemakers or other implanted electronic medical devices; artificial heart-lung machines or other electronic life-support medical devices, and electrocardiographs or other worn electronic medical devices.
Page 4
WARNING (Use and storage) ● ● Do not overuse the device. For usage time and frequency, Use by unattended children or individuals with physical follow the instructions in the User’s Manual. disabilities should be avoided. Minors should use the device only under the supervision of a guardian who has User Prohibition Failure to comply may cause physical injury.
Page 5
WARNING (Use and storage) ● ● If any problem occurs during use, including the presence of If you are currently undergoing dental treatment an abnormal odor or excess heat, stop using the device. or have teeth fillings, choose a lower intensity level and apply the device on a different area.
Page 6
ATTENTION (Use and storage) ● ● Before use, check to make sure the electrode head is not Do not use the device outdoors. cracked, deformed, or broken. Do not use the device if it is Failure to comply may cause a failure of the device. Prohibition damaged or malfunctioning.
Page 7
ATTENTION (Use and storage) ● ● Use only Level 1 upon first use and until you are accustomed When using on the same area again, be sure to leave an to use. interval of 24 or more hours between treatments. Mandatory Mandatory Failure to comply may cause an accident or injury.
Page 8
WARNING (The power supply) ● ● Use the USB cable included with this product. Do not soak into, spill over or wash USB cable with water. Plug the AC adapter directly into a wall power outlet and Failure to comply may cause an electric shock, short circuit, fire, or failure do not overload the electric circuit.
Page 9
WARNING (The power supply) ● Before charging the device, check to ensure the charging terminal and USB cable are not wet. Failure to comply may cause an electric shock, short circuit, or fire. Mandatory ● Compliance Do not pull the USB cable when moving or lifting the device. Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.
Names and Functions of Components Main Body ● ● Front view Rear Electrode head Level lamp Level button Power button ( ) Charging Lamp ( ) Charging terminal (USB Type-C™)
Page 11
Accessories ● ● ● USB cable (USB Type-C™) Flawless Serum Moisture 20G User’s Manual Flawless Serum Smooth 20G The design and specifications of the device and attached accessories are subject to change for improvement purposes without notice. • USB Type-C™ and USB-C™ are trademarks of the USB Implementers Forum. Functions Safety functions ●...
Before Use Charge the device Using a household power outlet You can check the remaining battery level Household power outlet through the Charging lamp ( ). Charging Lamp ( ) Charging Lamp ( ) Display Charging Guide Display Charging terminal White lighting The battery is sufficiently charged.
Page 13
Pre-testing on Skin When using the device for the first time, always test for compatibility. ATTENTION ● Be sure to perform a pre-test in order to prevent skin problems from occurring. ● If a rash, reddening, itchiness, stinging sensation, or other abnormality occurs at the pre-testing site, immediately stop the pre-test.
How to Use Basic method of use Be sure to remove makeup and wash your face before using the device. Turn on the device Select the level The Charging lamp ( ) and Level 1 lamp will be lit, and the Each time the Level button is pressed, levels can be adjusted.
Page 15
Apply the included skin-care product evenly on the site to be Care for the skin after the treatment treated and then move the device so that the entire surface After treatment is complete, rub the remaining skin-care product into the skin and then use your of the electrode head comes in contact with your skin usual basic skin-care products to condition the skin.
Page 16
How to move the device Repeat the movements ① to ② within the specified time for a total of five sets as shown below. ① ② STEP1: STEP2: Gently move from under the eyes to the temples, Gently move in circles between the eyebrows, then slowly then move slowly in a circle.
Page 17
① STEP1: STEP2: Gently move from under the eyes to the temples, Gently move in circles between the eyebrows, then then move slowly in a circle. slowly pull upward along the bone above the eyes. * If you want to focus on the under-eye area, use only step 1 for 2.5 minutes.
After Treatment How To Clean Clean the device after each use for hygienic reasons. WARNING ● ● When cleaning the device, be sure to turn it Do not wash the device in water. off and disconnect the USB cable from the This device is not waterproof.
Page 19
Storage ● Store in a clean, well-ventilated place out of the reach of children. ● Remove the USB cable from the main body when not in use for a long period of time. ● Do not leave the device in hot or humid places, such as near flames, in bright sunlight, or in a bathroom. Maintenance and Inspections ●...
Additional Information Troubleshooting If you perceive any abnormality while using the device, verify the following points before arranging to have it repaired. Problem Possible Causes and Solutions Press and hold the Power button ( ) for about one second. The device does not turn on. The device has run out of power.
Page 21
Problem Possible Causes and Solutions Your skin is dry. Moisturize your skin by applying the included skin-care product. The radio frequency (RF) does not feel warm. Raise the level. Lower the level. Be sure to use Level 1 on the first use. EMS causes uncomfortable tingling or pain.
Frequently Asked Questions Try to use five days a week (once daily, up to five minutes). When using on the same area again, be sure to leave an interval of 24 or more hours between treatments. What is the recommended duration * The device can also be used on the face except for the eyes.
Product specifications Rated power supply DC5V 1.0A Power consumption Approximately 2W (when charging) Battery Lithium ion battery Approximately 3 hours Charging time (May vary depending on the charging environment.) Approximately 40 minutes (when fully charged) Operating time (May vary with conditions of use and the EMS level.) Outside dimensions W 36 ×...
After-sales Service About the skin-care product included with the device ● Please contact your local distributor for detailed information on products and purchases. * Sales may be discontinued without prior notice. Rechargeable battery ● The rechargeable battery is a consumable item. (not covered by the product warranty) ●...
Page 25
Operation Steps Refer to figures ① to ④ below to remove the battery. ① Remove the sticker from the ② Slide the upper housing of the device, ③ Unscrew the four screws on ④ Remove the battery from the bottom of the product and remove the upper and lower housings, the lower housing and remove battery compartment.