Doing so may present a hazard and will void any warranties. Under no circumstances can Pozyx be held liable in any way shape or form for any defects, damages, injuries, direct or indirect, that are the result of handling, using, installing or any...
5 About this Manual Audience This manual is intended for users of the Anchor in conjunction with the Pozyx Enterprise System. Any other use outside of the system is deemed incompliant and will void any warranties of the anchor, tag, system, or any Pozyx hardware.
By connecting to the gateway, users can receive the real-time positioning data. • The Pozyx web application. The web application is a visual interface to configure and manage the Pozyx system. It can be run locally from the gateway itself or from the Pozyx cloud.
-40 °C to +70 °C Storage conditions 8 Installing the Anchor Mounting Anchors Mountain brackets allow users to install the Pozyx Anchors security to a wall or ceiling. Three types of mounting brackets are available to mount an Anchor: VESA pole mount (90-020-0001) •...
Page 7
VESA wall mount (90-020-0002) • VESA ceiling mount (90-020-0003) • The Anchor is mounted with 4 x M4 screws on the mounting bracket.
Connecting Cables Pozyx Anchors can be connected through Ethernet. Each Anchor has 2 RJ45 100Base-T ports. They can be used to link up anchors in sequence which reduces the total amount of wiring required. We call this Daisy Chaining of Anchors.
Powering the Anchor There are two options to power an Anchor: Using Power-Over-Ethernet (PoE/PoE+). This option requires an Ethernet switch • with PoE capability is placed between the gateway and the first Anchor in a daisy- chain. Each Anchor will provide power on the outgoing Ethernet cable for the next Anchors in the chain.
Anchor Headers Two types of headers are available for the Anchor: The header 90-010-0101 provides IP66 and IP67 ingress protection to the Anchor. • The Ethernet cables enter the Header sideways. The header 90-011-0001 can optionally be used to guide the external cables. The •...
8.4.1 Mounting the IP66/67 header 1. Place the RJ 45 connector on the Ethernet cable according to the T568B convention when using an Ethernet cable without pre-confectioned connectors. Warning: Make sure that the RJ45 connectors are suited for the deployed Ethernet cable. 2.
Warning: To provide IP66/67 protection, the diameter of the Ethernet cables must be tailored to the grommets provided with the header. The standard cable diameter should be 7 mm ±10%. Contact Pozyx for other options. Warning: Make sure that the blind grommet, that is provided with the IP66/67 header, is placed in the right side cable gland if the Anchor is the last in an Anchor daisy-chain.
A tag should be surrounded by anchors in all directions. This can be achieved by • placing an Anchor in each corner of the room in which tags are to be positioned. 8.5.1 Specific guidelines for 2D positioning: Place the anchors high and in line-of-sight of the user. •...
The purposes of the Bluetooth functionality of the Anchor are: Data offload from the tags • Firmware upgrade of the tags • Tag configuration • The Bluetooth functionality is controlled by the Gateway in the positioning system. More detailed information can be found at https://docs.pozyx.io/hs.
Solid red Link on Ethernet interface established Blinking orange IP address obtained Solid orange Anchor operational, no UWB activity present Blinking Green Anchor operational, UWB activity present Solid Green General malfunction Blinking red Pozyx reserved mode Blinking blue 10 FAQ...
11 Disposal When the product reaches end of life, dispose it properly in accordance with local laws and regulations. Disposal of the packaging material (EU directive 94/62/EC on packaging and packaging waste) This marking indicates that the product’s packaging material can be recycled.
2. This device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes and Modifications not expressly approved by Pozyx NV can void your authority to operate this equipment under Federal Communications Commission rules. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
12.3 CE Compliance Statement The manufacturer, Pozyx NV, Vrijdagmarkt 10/201, 9000 Gent, Belgium declares that the products: 10-002-0012: Pozyx Anchor V2.1 with BLE • is conform to the following Directives and standards: 2014/53/EU (Radio Equipment Directive) Article 3.1a : Safety and Health IEC 62368-1: 2014;...