Advertisement

Quick Links

D CH
U
CONTENT
I Preface
1.1 Notices when open the cases
1.2 Install environment
3.5 Sensor dimension
4.2 ATP Action Timing Diagram
1
I Preface
1
2
Thank you for your using of CAM888 cam controller, here after is called controller, which is
2
produced by DUCH automatic technology CO., Ltd. The controller adopts the newest
3
technology. And our company has the completely independent intellectual property. Besides, it is
3
the national invention patent product. The characteristics are as following:
4
Leading technology
4
☆ It uses the high speed microprocessor, the large-scale field programmable chip and the
4
entire digital high accuracy high speed control.
5
☆ Gear change system: Intelligent calculate of stopping at top dead end.
5
6
☆ It is dynamic indicating for cam angle setting, which is more human nature.
7
High performance
8
☆ The displayed precision of angle measurement may amount to ±0.1°.
8
braking test has 2 channels outputs
9
channels outputs.
9
indication has 1 channel output. Totally 16 channels output.
10
Before using the controller please read the manual carefully Make sure it is used correctly
10
and then it will display its high performance. Moreover, this manual is an appendix which is sent
12
with the controller. Please take care of it after you have used it. So that it will work when you
12
12
repair and maintain the controller.
12
1.1 Notices when open the cases
13
When open the case, please confirm the following items carefully.
15
◇If there is any damage during the delivery.
15
◇Check if the rating value on name plate is the same with your requirement. Make sure the
16
accessories are whole.
16
◇Any question please contact us or the supplier.
16
16
1.2 Install environment
◇The height is no more than1000m;When it is over1000m, it will reduce the capability of
17
17
the controller because of the thin air.
17
◇Environment temperature: -10℃~+40℃ Environment humidity: No more than 50% at
18
40℃. No more than 90% below 20℃.
18
◇When the installation base allowable vibration is 10~150HZ, its maximum vibration
18
acceleration should be no more than 5m/s².
◇Power supply:DC24V1A.
programmable scissors cam has 6
.
has 1channel output.system normal
Production value
2
Users Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CAM888 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DUCH CAM888

  • Page 1: Table Of Contents

    I Preface I Preface 1.1 Notices when open the cases Thank you for your using of CAM888 cam controller, here after is called controller, which is 1.2 Install environment produced by DUCH automatic technology CO., Ltd. The controller adopts the newest 1.3 Warning of installment...
  • Page 2: Warning Of Installment

    D CH Users Manual II Function And Specification 1.3 Warning of installment ◇Never install it on combustible devices. Never put the combustible things beside it. Never 2.1 Function list SPM/Angle Display: Continuous mode, showing the value of SPM when SPM>8, install it in the surrounding which has volatile gas, dust, point-blank sunshine, high otherwise showing the angle.
  • Page 3: Installation And Connection

    D CH Users Manual III Installation and connection 3.2 Parts connection diagram 3.1 Installation dimensions Outline dimension : Caution: 1. Make sure the voltage and the poles. 2. Make sure the plug inserted into the socket totally and in correct way. Leave the wire a suitable length for disassembly.
  • Page 4: Terminal Board Description

    D CH Users Manual 3.3 Terminal board description: 3.4 Interface circuit Name Index Cutting cam output Cutting cam output Cutting cam output Cutting cam output Cutting cam output Cutting cam output (production count reaches output) Cam output Cam output Cam output Cam output 3.5 Sensor dimension Cam output...
  • Page 5: System Interface

    D CH Users Manual IV System Interface 4.2ATP(Automatic positioning the Top dead end point) Wiring example: 4.1ATP(Automatic positioning the Top dead end Point) Action Timing Diagram ATP (Automatic positioning the Top dead end Point) ATP Function Guide a. IN2 ON(Inch----ATP Function Disable(OUT2 ON)...
  • Page 6: Parameter Setting

    D CH Users Manual V Parameter Setting 5.1 Key specification Operation panel function table Name Function Item Increase/Up Menu up or numerical value increase. When adjust the numerical value, keep pressing it to make the value increase quickly. Reduce/Down Menu down or numerical value reduce. When adjust the numerical value, keep pressing it to make the value reduce quickly.
  • Page 7: Cam Parameter Setting

    D CH Users Manual more than 3 seconds to make the controller enters into setting status. Here, the digital Cam parameter setting steps: : monitor will flash. Then press to select the menu. Press to enter into the submenu. Enter setting status. Press 5.4 Cam parameter setting to select the cam code Cutting Cam parameter setting:...
  • Page 8: System Parameter Setting

    D CH Users Manual c. By now the starting angle(oN) in submenu start to flash. Press to select the seconds to make the controller enters into setting status. item. Adjust it until the end angle(oF) flashes. Press to enter the adjustment. Now the b.
  • Page 9: Counts Setting

    D CH Users Manual The method is as following: VI Protection and alarm a. Put the press in inch mode, then adjust the slide to the lowest point(180°). 6.1 Protection And Alarm Instruction b. Use the same steps as 5.5.1 to enter the system menu. The controller will shut off system ‘Ready’...

Table of Contents

Save PDF