Pellet Burner
PRITY
Instructions for installation, adjustment
and operation

Advertisement

loading

Summary of Contents for Dabos Prity

  • Page 1 Pellet Burner PRITY Instructions for installation, adjustment and operation...
  • Page 2 Pellet Burner Type Prity Instructions for installation, adjustment and operation Technical data: Thermal power from 10 to 35 KW - Automatic ignition - Automatic pellet feeder - Automatic monitoring of the combustion process - Modulation of thermal output according water temperature...
  • Page 3 - At rated power - 4.5kgs per hour Table of contents: 1.Principle diagram 2.Safety rules 3. Instructions for installation, commissioning and safe operation. 4. Service technician guide The Pellet Burner –PRITY is produced, in full compliance with the European and the Bulgarian standards.
  • Page 4 1.Principle diagram 1.Control panel 2.Pellet inlet 3.Flange connector 4.Combustion chamber 5.Feeder cable 6.Auger plug 7.Temperature controller 8.On/Off 9.Fuse 10.Auger transporter 11.Gear screw 12. Feeder cable 13.Stand 14.Heat resistant tube...
  • Page 5 2.Safety rules Installation should be executed by qualified and authorized skilled people in heating and electrical systems. The site and correct burner installation must be chosen carefully, following the directions for safety. Install away from flammable objects! Never attempt to make changes to the burner! Never use flammable liquids to ignite! Operation and servicing of the burner must be carried by an adult familiar with the operating conditions.
  • Page 6 The burner is designed FOR BURNING WOOD PELLETS ONLY! Constructive safety rules The burner is controlled by a microprocessor. The process of ignition is being monitored by illuminance sensor and if it does not ignite the first time, microprocessor files a second dose of pellets and starts the ignition again. If there is no ignition, after the second cycle, the burner goes into "ALARM"...
  • Page 7 Connecting to the boiler The device should be placed in a way, so there will be enough space for cleaning, removing the soot from the burner, the boiler and the draught pipes. The burner must be installed in the boiler outlet with the relevant isolation, joined up with nuts or puller.
  • Page 8 Start the burner Check if the pump is connected to the electrical network and, if it is controlled by a thermostat, check the thermostat, too. You should make the necessary adjustments in temperature (maximal - “switch off” temperature and minimal – “switch on” temperature) according to customer needs, and to check or change some parameters recommended by the manufacturer (accessed ones).
  • Page 9 If the pellets don’t ignite, a new attempt for their burning will start automatically. If the sensor does not detect any flame during operation, the burner will stop and a mode ALARM will start. If more than few attempts for ignition appear unsuccessful, for example, if the fuel ends, then the device turns off the normal algorithm and a mode ALARM will start –...
  • Page 10 That is as a result of the fact that the initial dose of pellets is bigger than the necessary and pellets are accumulated at the ignitable heater area. If there are charcoals from the previous combustion, they start the burner, a flame is registered and the burner gets in operating mode before the pellets start burning by the ignition heater and the flame subsides from the big quantity of fuel.
  • Page 11 Remove and clean the burner’s throat, remove and clean the burner and screw it to the boiler again, every 24 or 48 hours. Periodically check the flue of the boiler and if there is congestion it should be cleaned. Check the burner control with a gas analysis instrument once a year. ATTENTION! ALL SERVICES ON THE ELECTRICAL SYSTEM AND THE BURNER MUST BE DONE BY AN AUTHORISED MANUFACTURER’S SERVICE.
  • Page 12 Technical maintenance ADJUSTING THE CONTROLLING LOGISTICAL MODULE Mode”Start” - "Start" is displayed Cleaning is activated for a certain time (Parameter # 61 - "Blowing" Feeding with an initial dose of pellets (Parameter#02-“Start Feed”-the fan is turned off, the heater is turned off. The heater and the fan are turned on and set at desired duty% (Parameter#04-“Start Fan”) Wait for the iluminance sensor to detect stable flame at value above...
  • Page 13 5. The ignition heater operates for about 1 minute. 6. The flame is detected, if the flame intensity goes below the extinction burner level, the device goes into mode “Start”. 7. After the preset time elapses (Parameter#08”IgnitionMax Time) the device goes into mode ”Burning”. Mode”Burning”-the inscription “Burning”...
  • Page 14 the burner will run at Level1 for the set time, and then will stop. If room thermostat changes back to ON before time elapses, the burner will revert to normal operation. 11. If burner is stopped due to room thermostat, and (Parameter#28-“ AMB_DELAY”) is not “0”, after room thermostat changes back to “ON”...
  • Page 15 4.Service Technician Manual Start/Stop - Manual switch on - set the controller in “On” state by pressing the [Start] button. Note: It is possible that the device starts automatically, if the program of the clock is enabled or GSM tele-control “on” command is issued. - Manual switch off - set the controller in “OFF”...
  • Page 16 2. Basic display, mode”On”, it is switched on when you press [Stop] button. Row 1: Boiler temperature sensor reading - of 27 ºC mode “On”. If no sensor is connected or sensor reading is over 99 ºC - “no” inscription is displayed–...
  • Page 17 “Y” in mode ”Burning” shows the current level from 0 to 3 Row2: Current mode of the burner and the current time “Start”-initial pellets feeding and ignition “Ignition”(ixxx)-where x is the state of the flame “Retry”-a new ignition attempt “Burning”-indication for burning (OK/No) and the state of the flame(ixxx) “Purging”-purging the combustion chamber, only the fan operates “Cleaning”-cleaning the combustion chamber...
  • Page 18 “S”-maximum preset operating level of the burner Row 2: Preset operating temperature min/max(45-65ºC) “FFF”-indication for the sensor of flame-parameters( 0-240) The more intense the flame is, the greater the value is. “AT”-Ambient (room) thermostat state: “ON” / “OFF” Correction: Correction of the preset temperature cycle by pressing the [OK] button subsequently Change the value by using [Dn Arrow] or [Up Arrow] or digits [C]-delete...
  • Page 19 Change the value by using [Dn Arrow] or [Up Arrow] or digits [C]-delete [OK]-for confirmation [ESC]-for exit from the menu Timer. Disabl Timer. Disabl Timer. Disabl 5.Screen #5-setting of the 13:15:12 [ 13]:15:12 13:[15]:12 Timer by pressing the [Timer] button twice Timer 1 Adjust From-11:15 To -16:30...
  • Page 20 Timer 2 Adjust From- 16 : 30 To- 22 :45 Row1: The number of the chosen timer Row2: Setting of the time range of the timer Setting of the time range of the timer in 15 minutes Edit by pressing the [OK] button Put “>”...
  • Page 21 Edit by pressing the [OK] button or just press[1] Change the value by using [Dn arrow] or [Up arrow] or digits [ESC]-for exit from the menu Set temperature difference to switch from maximum to minimum value- (standard 8 ºC) Main Menu 2-dTreg max->...
  • Page 22 * Entry in this menu is only possible in off mode Main Menu 5-Lang/Език Selection of Language for displaying information. Edit by pressing the [OK] button or just press[5] Change by pressing [Dn arrow] or [Up arrow] from the menu [ESC]- exit from the menu Set access code to the main system settings Main Menu...
  • Page 23 * Entry in this menu is only possible if you enter the correct password for access, on the top row For full access to the system it is necessary to set “password = “169” Parameters: in ”Parameters” menu ParamName YY ParamValue “ParamName”...
  • Page 24 Description of parameters Display Label Name of the Description parameter Tmin Tmin Minimal start time of the burner - 50°C Tmax Tmax Maximum temperature for the burner to stop- 70°C StartFeed ON Start Auger Time for initial pellets feeding 35 sec StartMaxTime Start Max time Maximum ignition time...
  • Page 25 StartFlame Start Flame Flame for indication of the ignition(above value) [10.00%]=100% Burn.Feed ON Auger Run Operating cycle of the auger in Ignition mode[0÷01.0]- 1.0second Burn.FeedPause Auger Pause Operating cycle of the auger in Ignition mode[0÷25]- 25seconds Burn.MaxTime Ignition Max Duration of Ignition Time mode[2÷30]- 2minutes30seconds...
  • Page 26 Burning mode, Level 2 (below 100%) [-1.5%]-98.5% Heat-Fan 1 Burn Fan 1 Operating cycle of the fan in Burning mode, Level 1 (below 100%) [-1.5%]-98.5% StopMaxTime Stop Max Time Duration of mode OFF[7’00]- 7minutes StopFlame Stop Flame Flame in mode OFF,(below value)[7.0%]-70 Pump T Pump T...
  • Page 27 AutoClean Purging Duration of activation of the lance nozzle / scavenge From 0.2 to 10.0seconds in 0.1 sec. and 1 to 25min in 5 sec. F-REG F-REG System parameter. Do not change. AutoRestart AUTO Automatic restart period during RESTART burning. (set to 0 will deactivate this feature) Time...
  • Page 28 WARRANTY REGISTRATION CARD №.........
  • Page 29 Product:Pellet Burner………………………………………………………… Product serial number……………………………………………………… First registration………………………………………………………… Product Warranty………………………………………………………. Byer:………………… Seller………………………. /Signature/ / Signature/ Commissioning on………………………………………………………………. Authorized service/technician………………………………………………… ………………………………………………………………………………… The user is familiar with the operating instructions of the product User:…………………………………… /Signature/ Warranty : The manufacturer guarantees the correct and flawless operation of the product only in accordance with requirements for installation and usage, in commissioning and service.