Page 2
The SafetyMOB system consists of a helm unit attached to the life jacket or the driver and a boat unit that is mounted in the boat and connected to the boat's existing emergency stop. The helm unit communicates constantly with the boat unit, if you fall overboard the communication is interrupted and the engine stops.
Page 3
(NOTE ensure that cable stub is long enough that it is possible to connect it to the SafetyMOB boat unit) and connect the two cables to the boat unit cables marked NO and C (the boat unit is now connected in parallel with the existing emergency stop).
Page 4
SafePort Marine Installation in a boat with a short-circuit kill switch system. Installation in a boat with a breaking-up kill switch system. SafePort Marine email: info@safeportmarine.se tel: +46 8 501 64 306 www.safeportmarine.se page...
Page 5
SafePort Marine System Startup When SafetyMOB is started you hear 2 ‘chirps’ from the boat unit to indicate that the system is active and has synchronized with a registered helm unit. If no ‘chirps’ is heard during the first 10 seconds you should give the helm unit a little shake to ensure that it is transmitting. If this does not help, but you hear a single ‘chirp’...