  • Page 1 P r o c e s s C o n t r o l b y D e s i g n In stru men t Trai n in g Gu id e Mo d el 990X Fl or i te I nte rna tional , I nc.
  • Page 2: Product Introduction

    1.0 Product Introduction 1.1 The System The 990x is a versatile full-featured measurement and control instrument - with precision multiple port and channel capabilities. Its operating control primarily supports point-n-click navigation. It supports an optional mix of up to eight independent full function input measurement ports and advanced technology output ports.
  • Page 3: Communication

    1.5 Communication The communication facilities provide data acquisition, command and control functions, and support information gathering and reporting, and alarm signaling. It has a built-in EIA-TIA232 standard interface, and is optionally configurable for EIA-TIA485 two wire multi-drop LAN operations. Wide Area Networking is supported by optional built-in modem, or optional 10/100 BaseT Ethernet.
  • Page 4: Table Of Contents

    1.11 Table of Contents Section Title _________ _________________________________________ Product Introduction The System The Technology The Applications The Organization Communication Alarm Monitoring Process Controls Operator Controls Operator Indicators 1.10 Diagnostic Capabilities 1.11 Table of Contents 1.12 Revision History Installation Signal Wiring Accessories Indicators Normal home screen fields...
  • Page 5 Notices Medical Alert FCC Compliances EU Compliances Copy Rights Hazardous Wastes Legal Notices...
  • Page 6: Revision History

    1.12 Revision History Effective Date Revision Enhancement 05Jul2007 1. Initial assembly of documents and organization 20Nov2007 1. Completion of pictorials 05Dec2007 1. Complete initial section text coordinated with pictorials 11Dec2007 1. Initial release revision complete - serial protocol exception 28Jan2008 1.
  • Page 7 2.0 Installation and Accessories This section describes the various system electrical wiring requirements, and provides information on the various available mounting accessories including table top, panel and rack.
  • Page 13: Indicators

    3.0 Indicators The home screen is the instruments central information and navigation indicator. The home screen is displayed following initial power application, and automatically follows the make-model screen banner. It provides an over-all view of instruments normal operation, and includes display of alarm conditions. 3.1 Normal home screen fields 3.1.1 Cursor - points to port even when port is Off 3.1.2 Channel - numbers 1-4 (Ports 1-8)
  • Page 14 3.2.2 Alarm Type Definitions Abbreviated indicators for each alarm type are shown on the display and are defined as shown below. The strings of one or more indicators are justified to begin in the least-significant position of a value field. Service Time Quantity 1 Quantity 2...
  • Page 15: System Controls

    4.0 System Controls The primary instrument controls consists of eight front panel tactile snap-action keys - and a serial communication capability. Every function that can be accomplished by using the keys can also be accomplished by serial communication commands - the aspects of which are described in the Protocol section.
  • Page 16: Navigate Controls

    4.1 Navigate Controls Navigation functions performed from the home screen are follows: 4.1.1 Select a port using the keys 4.1.2 Select a port process value to be shown show on the home screen 4.1.3 Change the value of a channel program variable 4.1.4 Enter the Global System Settings selection menus 4.1.5 Quickly navigate to certain special values requiring frequent changes 4.1.6 Start and stop control functions...
  • Page 17 4.2 Operate Controls The control function of the keys is dependant on the context of the function that has been requested to be accomplished as follows: 4.2.1 Home Screen - navigates to port I-O Screen Port I-O Screen - selects view or program View Screen - selects home screen value Program Screen...
  • Page 18: Navigation

    5.0 Navigation This navigation section provides an overview of the various values that are available to set-up desired operating characteristics that establish how the instrument is desired to perform, and to review the operating state of the desired performance. Although navigation is described for keypad operation - the same operating characteristics set using the keypad are supported by serial communication - for which a detailed description is contained in the Serial Protocol section of this document.
  • Page 20 5.2 Navigate Select The selection screens provide a secondary navigation layer for the operator to specify whether viewing or programming is desired for a port that is an input, an output or is now OFF. The screens shown below are displayed as a result of having pressed the [SELECT] key while viewing the home screen.
  • Page 21 6.0 Process and Set-Point Values This Process Values (PV) and Set-Point Values (SP) section provides a detailed description of the various system map values that are used to set-up the instruments desired operating characteristics that establish how the instrument is desired to perform, and discusses the various process values that show the operating state that are the outcome of the set-up.
  • Page 22 6.1 PV Measurements This section describes special screen services - and describes each of PV Measurements which are functions of a signal input into the instrument. 6.1.1 Change Home Screen Value The present value shown on the home screen is indicated by a star (*) prefix. To change which value is displayed - point the cursor to the desired value and press the [SELECT] key.
  • Page 23 6.2 PV Program Value This section describes how to program the various PV values - which determine input signal service, alarm functions, measured value communication type, logging type, and the port name. PV Program values are static and updated only after the value is saved. 6.2.1 Value Programming 6.2.1.1 Program a value by pointing the cursor to its line and pressing the [SELECT] key.
  • Page 24 6.2.2.3 When the port is desired be an active output from being an active input, or become an active input from being an active output - contact factory for interface module re-configuration. 6.2.2.4 Active Signal Input An active signal input Port Type has two separate fields - input signal type field, and sensor excitation voltage field.
  • Page 25 An option is available that performs a two-point frequency interpolation using the analog signal process to be interpolated as shown above. The pulse signal is input directly in Hz (pulses/sec) to evolve engineering rates. 6.2.9 PV Rate Filter This value determines the amount of filtering applied to rate or value input measurements. Filtering ranges from +0 to -20 dbHz (1-10 sec) of noise and jitter suppression.
  • Page 26: Sp Status

    6.3 SP Status This screen provides output port status information to the operator and is shown below. Refer to the Control Functions section which describes in greater detail the set-up, operation and termination. 6.3.1 SP Function This control service type reflects the selected service type that has been programmed for the port or channel. It identifies the type of process control the output is required to perform, and the amount of the control output as appropriate.
  • Page 27: Sp Programming

    6.4 SP Programming This section describes how to program the various SP values which determine output signal service, linked input signal source, output service function, set-points, units de-interpolation, and the port name. SP Program values are static and updated only after a changed value is saved. 6.4.1 Value Programming 6.4.1.1 Program a value by pointing the cursor to its line and pressing the [SELECT] key.
  • Page 28 6.4.2.5 Signal Type Field Program the signal type field as desired - then use the [►] key to move to the output link field and select the desired INPUT port from which the output gets the signal for it to perform its selected Function. Save the new Port Type.
  • Page 29 6.4.7 Port Name A string of up to twenty free-form alpha-numeric characters may freely be programmed for use in identifying input measurement purpose, type, or location.
  • Page 30: Global Settings

    7.0 Global Settings This section provides a detailed description of the various system wide variables used to set-up and review the overall operating characteristics that establish how the entire instrument is desired to perform. The values include those provided only for review, those that can be selected, and those that invoke immediately action.
  • Page 31 7.1 Information To enter the information service screen - point the cursor to Information on the Global Settings screen and press the [SELECT] key. This screen contains system information values and configuration states. These values are not programmable, with the only exception being the Factory Set immediate action selection described below which erases present programmed values and replaces them with factory default values.
  • Page 32: System Power Control

    7.2 System Power To enter the System Power function - point the cursor to System Power on the Global Settings screen and press the [SELECT] key. This is an immediate action selection. 7.2.1 System Power The System Power functions allows the user to cause power to equipment connected to the instrument to placed in an Off state, allowing the user to conduct installation services and diagnostics.
  • Page 33: Control Service Screen

    7.3 Control Service To enter the Control Services screen - point the cursor to Control Services on the Global Settings screen and press the [SELECT] key. These Control Service settings are programmable but are not live updated. They establish operation of the several system level operating controls.
  • Page 34 7.4 Communications To enter the Communications service screen - point the cursor to Communications on the Global Settings screen and press the [SELECT] key. The communication variables are programmable selections. The Communications settings are programmable and are used to establish the instruments communication parameters that control the systems three serial ports to send alarm, log, or data reports.
  • Page 35 7.5 Date and Time (OPTION) DATE and TIME is an option. When the option is not installed - the Global Settings will not list it as an available choice, and the service screen will not appear. When the option is installed - enter the service screen by pointing the cursor to DATE and TIME on the Global Settings screen and press the [SELECT] key.
  • Page 36 7.6 Data Logging (OPTION) DATA LOGGING is an option which requires the DATE and TIME option to additionally be installed. When either option is not installed - the Global Settings will not list DATA LOGGING as an available choice, and the service screen will not appear. When the option is installed - enter the service screen by pointing the cursor to DATA LOGGING listed on the Global Settings screen and press the [SELECT] key.
  • Page 37: Process Controls

    8.0 Process Controls This section provides a detailed description and operation of the instruments various control functions.
  • Page 38 8.1 Manual Control Manual control is a continuous manually oriented process - performed on a port-by-port basis. This control type causes an SP Rate signal programmed by the operator to be output to a controller. The controllers’ delivery rate signal is independently monitored and may be indicated by a linked port PV Rate.
  • Page 39 8.2 Batch Control Batch processing is a non-continuous process that is started, conducted, and terminated when a desired quantity has completed delivery. The operator may stop batch delivery at any time prior to completion. 8.2.1 Set-Up The operator programs values shown above for each output port that is desired to perform batch delivery. 8.2.1.1 SP Function - select Batch 8.2.1.2 SP Batch - set desired delivery quantity 8.2.2 Start Batch...
  • Page 40 8.2.3.2 The operator may terminate any channels that continue with batching remaining in process by first returning to the home screen, then pressing the [STOP] key once. Note that the 'B' control indicators on the home screen stop blinking indicating that all batch processes are stopped. 8.2.4 Batch Type Selection The Global Selections for Control Service includes a "Batch Type"...
  • Page 41 8.3 Blend Control <PRELIMINARY> Blending is a continuous process that when started, causes slave SP Rates to be proportionate to the actual rate being delivered by the master. CAUTION Blending operate parameters are saved when power is lost allowing blending to continue after power is restored unless Pwr SP Clear is ON.
  • Page 42 8.3.1.2 Master Input Port Set-up The operator navigates to the output programming screen linked to the selected master input port, and sets the output port, linked to the input master, SP Function to Rate, and desired SP Rate. 8.3.1.3 Slave Channels Set-up The operator navigates to each desired slave output port and sets each SP Function to Blend, then sets the desired SP Blend rate percentage referenced to the master channels actual delivery rate.
  • Page 43 8.4 Monitor Service Monitor is an output port service that acquires the PV Rate from its linked input port, de-interpolates the rate to a selected output Port Type signal, and outputs the signal to other system process monitoring equipment. When an output port link is zero - it is not linked to an input port. The output port then functions to search all input ports for at least one alarm.
  • Page 44: Proportional-Integral-Differential (Pid)

    8.5 PID Rate Control The function of PID control is to produce output signals that will cause the rate of a process observed by the linked input port to be held constant to equal the output ports SP Rate. Proportional-Integral-Differential (PID) is a continuous rate control process performed by the combination of an output port whose SP Function is set for PID;...
  • Page 45 9.1 Bio-Medical Alert NOTICE WRITTEN AUTHORIZATION BY THE PRESIDENT OF FLORITE INTERNATIONAL, INC. IS REQUIRED PRIOR TO USING ANY FLORITE PRODUCTS OR SERVICES AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. 9.1.1 A critical component is any component of a life support device or system whose failure to perform can reasonably be expected to cause the failure of the life support device or system, or affect its safety or effectiveness.
  • Page 46 9.2.2.2 You must provide the FCC Part 68 compliance registration information from the equipment label when requested by the telephone company. Registrant: Florite International, Inc. Number: 5TUUSA-23969-DT-E 9.2.2.3 The telephone company will notify you of network changes that may affect proper functioning of your equipment, and may temporarily discontinue service, or require the equipment to be disconnected from the line, if it is suspected of causing harm to the network.
  • Page 47 9.3 EU Compliances 9.3.1 EMC Directive The European Union directive on electromagnetic compatibility (2004/108/EC) requires a non-European manufacturer to designate an authority representative in the Union-Community. Our European representative is: Compatible Electronics, Inc., 2337 Troutdale Dr., Agoura, CA 91301. 9.3.2 Waste Electrical and Electronic Equipment Directive (WEEE) The European directive WEEE aims to minimize the impact of electrical and electronic equipment waste on the environment and human health.
  • Page 48 9.4 Copyright Florite International, Inc. warrants that every reasonable effort has been made to assure the accuracy of the information contained herein, however, assumes no responsible for its use. The information is subject to change at any time without notice, and no part of it may be reproduced without prior written agreement...
  • Page 49 Limited Warranty. Prior to sending the instrument to Florite for service, contact www.florite.com, Service Department, who will issue a return-materials-authorization number.
  • Page 50 9.6 Legal Notices 9.6.1 Trademarks and Patents Florite and the Florite Logo symbol are trademarks of Florite International, Inc. Other trade names which may be used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.

Table of Contents