HS Salt electrolysis ........................1 Table of content ......................... 2 Specifications ......................... 4 Salt electrolysis installation ....................5 Structure diagram ........................7 Using the chlorinator ......................8 Warnings ..........................14...
Page 3
Introduction This manual contains all the necessary information for installation, troubleshooting and maintenance. Read the manual thoroughly before opening or using the unit. The manufacturer of this product will not be held responsible for any injury to and/or damage of the product resulting from improper installation or unnecessary/incorrect maintenance.
Specifications ZLAX0016 ZLAX0020 Electrolysis Unit 50 m3 75m3 Chlorine control EC 16 - 16g/h EC 20 20g/h Pool connection 50mm to stick Flow switch Flow control on EC unit Power supply 230V ~, 50 Hz Installation Attention! ○ The electrical installation should be done in such a way that: - The electrolysis and acid pump cannot operate if the filter pump is not working.This can be...
Salt electrolysis installation The salt chlorinator should be installed with the return line to the pool and through the water treatment line as shown in the diagram. A control valve must be installed on the main line. Before installing the salt chlorinator, make sure that the water flow matches the direction indicated by the chlorinator.
Page 6
Salt electrolysis The chlorinator's external power adapter must be connected to a power source that has a 30mA ground fault circuit breaker Preparing the pool water Make sure the pH of the pool water is at least between 7.2 and 8.5 and as close to 7.4 as possible.
When turned on, the unit will assume the last observed settings.. Chlorine Ideal business location Model productio 8g/h unit suitable for swimming pools = 40 m³ EC12 12g/h unit suitable for swimming pools = 60 m³ EC16. 16g/h unit suitable for swimming pools = 80 m³ EC20 20g/h= unit suitable for swimming pools = 100 m³...
Using the chlorinator 1. When the chlorinator is connected to the faucet, adjust the water flow with the valve to ensure that enough water flows through the salt chlorinator. 2. Before use, ensure that the salt concentration of the pool water is within the normal operating range (3.5- 4.5 kg of salt per m³), otherwise it may shorten the life of the Titanium cell.
Page 9
. Led monitor(displays the water temperature under normal operation, displays the corresponding error code if a problem occurs ) 2. Level indicator light (1 light stands for level 1,2 light stands for level 2 ..5 lights stand for 5 levels) 3.
Page 10
Error codes and corresponding solutions chlorinator Error code Reason for Remark Solution failure Cooling fin The temperature of the First check if error code E6 is present , if present temperature is too cooling fin is too high , check if the temperature sensor is connected,if high connected replace the sensor;...
Page 11
Error Reason for failure Remark Solution code The sensor in the The fault must be check whether the corresponding controller is not working solved manually temperature sensor is attached, replace the properly sensor if this is the case water temperature The fault must be check whether the corresponding sensor defective...
Page 12
Additional : operation and maintenance of the chlorinator 1. The mixture and maintenance of water and salt The operational state and maintenance of salt chlorinator 1.1 The calculation of the amount of water: Knowing the capacity of the pool is the first step in adding salt to the pool . Rectangular pool : length (meter) x width (meter) x average depth (meter) = pool water capacity ( cubic meters) Round pool: diameter (meter) x diameter (meter) x average depth (meter) x 0.785 = pool...
Page 13
The correct way to add salt: A) Turn on the pool circulation pump and allow the water circulation to begin. B) Turn off the chlorinator. C) Test the current salt level of the pool. D) Calculate the amount of salt needed to add to the pool. E) Add salt to the pool around the side of the pool, allowing the salt to dilute quickly and evenly in the water.
Warnings ○ Improper installation can create an electrical or chemical hazard, which can result in serious injury. ○ Keep the installation and chemicals out of the reach of children. Always wear safety gloves and safety glasses when working on the installation. ○...
Need help?
Do you have a question about the ZLAX0016 and is the answer not in the manual?
Questions and answers