The outputs are arranged in steps / taps delivering a higher VR-F Series microprocessor controlled Single Phase Voltage Stabilisers / Line or lower voltage. Conditioners automatically correct brownouts (by boosting low voltage) and over-voltages (by stepping down high voltage).
Please Note: VR Series Voltage Stabilisers / Power Conditioners are NOT FOR USE with life sustaining equipment, or any device where the power requirements exceed the “Maximum Output Rating” listed in the Specification table. VR-F Operator/ User/Product Manual (S1) Page VR-F Operator/ User/Product Manual (S1) Page SAUK-VR-F-2022-01 SAUK-VR-F-2022-01 https://www.sinalda.com https://www.sinalda.com...
If on delivery there is evidence of visible damage, do not attempt to install or start the Stabiliser / Conditioner. Advise the transport delivery company 2.7 Warranty and inform Sinalda UK, or the resale partner from whom you purchased the equipment. Model No...
Standard safety practices should be followed at all times. The unit must be grounded or earthed at all times when in use. VR-F Operator/ User/Product Manual (S1) Page VR-F Operator/ User/Product Manual (S1) Page SAUK-VR-F-2022-01 SAUK-VR-F-2022-01 https://www.sinalda.com https://www.sinalda.com...
Audible Alarm Stabiliser / Conditioner is supplied with a suitably rated IEC power will activate. On fault clearance Output will be cable. automatically re-engaged. VR-F Operator/ User/Product Manual (S1) Page VR-F Operator/ User/Product Manual (S1) Page SAUK-VR-F-2022-01 SAUK-VR-F-2022-01 https://www.sinalda.com https://www.sinalda.com...
If on delivery there is evidence of visible damage, do not attempt to install or start the Stabiliser / Conditioner. Advise the transport delivery company Overload Actual load current exceeds the model’s and inform Sinalda UK, or the resale partner from whom you purchased stated maximum rating. Audible Alarm for the equipment.
Conditioner – see Section 4.3. Any variation to the input power supply, up or down, will be monitored and adjusted by the VR Series Stabiliser / Conditioner. VR-F Operator/ User/Product Manual (S1) Page VR-F Operator/ User/Product Manual (S1) Page SAUK-VR-F-2022-01 SAUK-VR-F-2022-01 https://www.sinalda.com https://www.sinalda.com...
On fault correctly, but the Due to a continuous clearance system will output voltage is severe brown-out. require manual restart. persistently low. VR-F Operator/ User/Product Manual (S1) Page VR-F Operator/ User/Product Manual (S1) Page SAUK-VR-F-2022-01 SAUK-VR-F-2022-01 https://www.sinalda.com https://www.sinalda.com...
Local Voltage and Type of Load Connected Except as provided above, in no event shall Sinalda be liable for direct, indirect, A Description of the Fault special, incidental, or consequential damages arising out of the use of this Once you have the Returns Number and Shipping Address you should ensure product, even if advised of the possibility of such damage.