  • Page 1 Nerve Muscle Stimulators FM-B2404/PRO15AB Pain Relief Anywhere and Anytime...
  • Page 2 EXTENT YOUR WARRANTY TO 2 YEARS & GET SPARE PADS Register within 2 weeks after receiving your tens unit! Visit link or scan the QR code & Complete registration http://www.brilnurse.com CUSTOMER SERVICE If you have any problem, please be free to contact us! support@brilnurse.com...
  • Page 3: Table Of Contents

    Table of contents 1. SAFETY INFORMATION 1.1 General Introduction 1.2 Medical Background 1.3 Intended for Use 1.4 Contraindications 1.5 Warnings, Cautions, and Adverse Reactions 1.6 Patient Population 1.7 Potential Electromagnetic and Other Interference 1.8 Explanation of figures, symbols, warning statements and abbreviations on the device 2.
  • Page 4: Safety Information

    1. SAFETY INFORMATION 1.1 General Introduction Thank you very much for using our Nerve Muscle Stimulator. For you use this device safely, please read this user manual carefully before your first use. Please keep this user manual with your device for future reference.
  • Page 5 (sometimes as much as three to four times longer). In others, pain is only modified while stimulation actually occurs. EXPLANATION OF EMS Electrical Muscle Stimulation (EMS) is an internationally accepted and proven way of treating muscular injuries. It works by sending electronic pulses to the muscle needing treatment;...
  • Page 6: Intended For Use

    1.3 Indication for use (IFU) TENS: The device is designed to be used for temporary relief of pain associated with sore and aching muscles in the shoulder, waist, back, neck, upper extremities (arm), lower extremities (leg), abdomen and bottom due to strain from exercise or normal household work activities.
  • Page 7: Warnings, Cautions, And Adverse Reactions

    6) This device should not be used over poorly enervated areas. 7) This device should not be used on patients with serious arterial circulatory problems in the lower limbs. 8) This device should not be used on patients with abdominal or inguinal hernia.
  • Page 8 11.Do not recharge, use or leave the battery and device in any high temperature environment such as a location near fire or in direct sunlight. Doing so may cause the battery to overheat, ignite or rupture. 12.There is potential hazard from simultaneous connection of a...
  • Page 9 1)Please do not turn on the device before connecting the wires, electrode pads, device and body. 2)The electrode pads have been pasted to the appropriate part, and the mainframe and wire have been properly connected before it can be turned on.
  • Page 10 11. Electrical stimulators should be used only with the leads and electrodes recommended for use by the manufacturer. 12. Do not use it in the presence of explosive atmosphere or flammable mixture. Adverse Reactions 1. Potential allergic reactions due to the electrical stimulation or gel including skin irritation, redness, burning or hypersensitivity.
  • Page 11: Patient Population

    1.6 Patient Population The “Patient” is an intended user. Adults who suffer from sore and aching muscles in the shoulder, waist, back, neck, upper extremities (arms), and lower extremities (leg) due to strain from exercise or normal household work activities can use this Device.
  • Page 12: Explanation Of Figures, Symbols, Warning Statements And Abbreviations On The Device

    1.8 Explanation of figures, symbols, warning statements and abbreviations on the device Meanings of symbols used for marking described in instructions for use Caution! Type BF applied part Direct current Protected against solid foreign objects of 12,5 mm Ø...
  • Page 13: Device Presentation

    2. DEVICE PRESENTATION 2.1 Illustration of the Device On/Off switch USB port Time indicator Battery indicator Mode indicator A/B Intensity indicator Mode adjustment A/B / Pause B Intensity adjustment(+) A Intensity adjustment(+) Mode select Mode select A Intensity adjustment(-)
  • Page 14 Battery Indicator: Used for battery level display. When the battery is about to run out, a flashing battery symbol will appear on the display. It should be charged as soon as possible. However, depending on the settings and intensity level, the machine may continue to operate for a longer period of time.
  • Page 15 Icon Mode Name Description Simulation of Tuina is a hands-on body treatment Tuina which help with pain relief and relaxation Stimulate pain points in the hand area for pain relief or Hand muscle relaxation. It is a type of alternative...
  • Page 16 Stimulate pain points in the hip, sciatica nerve for pain relief or muscle relaxation. Stimulate pain points in the Foot area for pain relief or Foot muscle relaxation. Simulation of acupuncture provides the same sensation without needles, by utilizing...
  • Page 17 Stimulate pain points in the lumbar area for pain relief or muscle relaxation. Shiatsu is simulation of a type of finger and palm pressure, Foot stretches, and other massage techniques. Stimulating with a low frequency setting provides the Acupunc-...
  • Page 18 Stimulate pain points specifically in the ankle for Ankle pain relief or muscle relaxation. Random combination of basic Combina- modes tion Deep tissue massage therapy is similar to Swedish Deep massage, but the keeper Tissue pressure is beneficial in...
  • Page 19: Illustration Of The Accessories

    + / - Button: Intensity adjustment button, Select the A channel or the B channel by the A/B button, to touch once + button, the strength will increase by one, and touch once – button, the strength will decrease by one.
  • Page 20: Specification

    Included in this package ● Tens Device × 1pc ● Oval pads × 2 pcs ● Palm pads × 6 pcs ● Rectangular pads × 2 pcs ● Electric wire × 2 pcs ● USB cable × 1 pc ●...
  • Page 21 3.Check for any physical damage on the unit. Step 1: Connect the electrode to the device The FM-B2404 is equipped with two isolated channels A&B. This will allow you to set separate modes and separate intensities on each channel using the 2 outputs A, B. Before connecting the wires to the unit, decide which channel you wish to use (channel A or B).
  • Page 22 CAUTION: 1.Please make sure the device is on the OFF position when setting up the unit, adjusting the pads, or making a new connection. 2.DO NOT turn on the unit before you put pads on your skin. 3.Use at least one pair of pads. One pad alone will not work.
  • Page 23 Step 4: Turn on the device Push the “ON/OFF” switch located on the top of the unit to the ON position. Verify the channel indicator on the screen to make sure the device is on the same channel you wish to use. The “A” letter will blink to indicate channel A is working.
  • Page 24 Adjust Channel Intensity for channel A, use output(s) A: 1.To select the mode, touch any of the TENS modes or EMS modes displayed on the screen. The selected mode will blink. 2.Press intensity “+” button to increase the intensity. When changing the mode, the intensity level will automatically reset zero.
  • Page 25: Cleaning And Care

    Step 8: Turn off the device Push the “ON/OFF” switch located at the top of the unit to the OFF position. Step 9: Remove the pads from your skin Lift the corner of the electrode and gently remove it from the skin, and place them back on the protective plastic film.
  • Page 26: Cleaning The Device

    6. It may be helpful to rub skin lotion on electrode placement area during treatment down time when you are not wearing electrodes. 7. Never apply electrodes over irritated or broken skin. 5.2 Cleaning the Device 1. Remove the battery from the device before you clean the device.
  • Page 27: Cleaning The Electrode's Cords

    TO REMOVE YOUR ELECTRODES: 1. Lift the corner of the electrode and gently remove it from the skin. 2. It may be helpful to improve repeated electrode application by spreading a few drops of cold water over the adhesive side and turn the surface up to air dry.
  • Page 28 5. Please clean the main machine frequently. Use a piece of soft dry cloth to wipe the dirt on the main machine. Don't wash with water or clean with the detergent, thinner, volatile oil, etc. that contains chemical substances.
  • Page 29 ● Make sure the device is off when you clean it. ● Do not let water to get into the device. Cleaning and Storing Pad Clean: After using pads on your body, please drop a little clean water on the sticky side and use fingertips to clean it softly.
  • Page 30: Trouble Shooting

    6. TROUBLE SHOOTING If your device does not seem to be operating correctly, refer to the chart below to determine what may be wrong. Should none of these measures correct the problem, the device should be serviced. PROBLEM CAUSE...
  • Page 31 Adhesive gel Adhesive Adhesive gel pads need to pads Do not material ran out. be replaced. stick to skin even after cleaning and moistening the gel pad. Recharge the battery. Battery is low. Unit does not turn on or the screen is dim.
  • Page 32: Recommend Use Position

    7. RECOMMEND USE POSITION Neck Shoulder Back Neck Neck Abdomen Waist/Foot Hand Joint support@brilnurse.com...
  • Page 33 Medical Disclaimer All information is intended for you general knowledge only and is not a substitute for medical advice or treatment for specific medical conditions. The information contained here is intended to provide broad consumer understanding and knowledge of product offered.
  • Page 34 Warranty Dear customer, Thanks for purchasing our product and welcome to join the Brilnurse family! Brinurse is committed to be a mature and excellent seller with good reputation and high sense of responsibility. We are trying our best to provides all buyers with high-quality products and professional after-sales team.