Should warranty service be necessary, please contact the DWK Life Sciences Technical Services Department (+1.856.825.1100 option 4) for authorization and instructions. It will be necessary to remove the roller unit’s control housing in order to ship it to DWK Life Sciences. Please contact the DWK Life Sciences Repair Department for information.
Page 5
All requests for inspection must be made to the carrier within 15 days of receipt of shipment. The shipping carton should not be discarded but retained until inspection by a representative of the carrier is made. DWK Life Sciences takes no responsibility for damage to merchandise in transit. All such claims must be submitted to the carrier.
Fitting a battery of the wrong type, such as a non-rechargeable battery, can cause an explosion or fire hazard. DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 7
Do not operate this equipment in any manner not specified in this manual. It is recommended that a fire extinguisher always be located in areas where electrical instruments are being used. DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Do not modify the line cord that has been provided. If it does not fit the available outlet, contact your nearest DWK Life Sciences distributor for the proper line cord for your geographic area. DWK Life Sciences | 856.825.1100 | www.dwk.com...
If the wrong power cord has been shipped for your particular application, contact your nearest DWK Life Sciences dealer for the proper cord. The Top Drive Standard Roller Apparatus has been equipped with a 3-wire grounding type power cord. The unit is only grounded when it is plugged into an appropriate receptacle.
(including speed and bottle diameter) set to the factory defaults. You will need to set the new system to your bottle diameter and desired speed before using for production. (see section 2 above) DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Navigating between the three main screens is done through the four push buttons on the edge of the display. Up Arrow Select Enter Down Arrow FIGURE 2 – DISPLAY INTERFACE DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
If traction rings or ridges are at both ends of the bottle, measure both ends and take the average. Using the obtained measurement(s), enter the bottle diameter (in millimeters). DWK Life Sciences | 856.825.1100 | www.dwk.com...
Bottle Rotation Direction should be set to forward (Fd) to provide a counterclockwise bottle rotation. If the motor is replaced with a motor different than the speed it originally came with, it is recommended to consult DWK Life Sciences Service to determine if the Bottle Rotation Direction needs to be changed.
Down buttons to set the motor gear ratio. The default gear ratio setting is 60. NOTE: This value is pre-set at the factory and should NOT be changed without consulting DWK Life Sciences Technical Service if the proper value is unknown.
After 2 seconds, the system will return to normal operation. During any step in the calibration, the UP / DOWN buttons can be used to cancel the calibration, restoring the system back to normal operation. DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
(loud) will sound. The display will show (rOt). To disable this alarm, change the rAO parameter (included in the Factory Mode) from 1.0 to 0.0. This setting will cause the software to ignore the belt hall effects. DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
21.7 volts and need to be recharged. To disable this alarm, change the bAO parameter (included in the Factory Mode) from 1.0 to 0.0. This setting will cause the unit to ignore any battery problems. DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
) and Hydrogen Peroxide (H ), will reduce the lifespan of the unit. *The use of vaporized disinfectants damages the electronics and is not authorized under the warranty.* DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Motor runs but roller(s) will not turn; Cause: Drive and/or deck gear pulley(s) loose. Remedy: Tighten gear pulley(s) with hex key. Cause: Belt(s) worn or broken. Remedy: Replace defective belts. DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 23
Remedy: Replace defective board. Cause: Drive motor defective. Remedy: Replace defective motor. Cause: Line voltage varying by more than +/-10%. Remedy: Have mains checked by a qualified electrician. DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
110-120 VAC unit use 5x20 mm, 250 V, 1.0 A fuse and the correct cord set is used. 220-240 VAC unit uses (2) 5x20 mm, 250 V, 0.63 A fuses and the correct cord set is used. DWK Life Sciences | 856.825.1100 | www.dwk.com...
Replacement Batteries (2) Power Sonic Model PS-1230 Typical Battery Service Life - 2.5 to 3 years Assuming battery storage and operation in a 37 o C incubator DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 26
WHEATON® Standard Roller Apparatus FIGURE A – MAIN ASSEMBLY 52 POS TOP DRIVE STANDARD ROLLER – WSTPF511X-A-J DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 27
230V ASSEMBLY DRIVE UNIT, TOP DRIVE STANDARD WSTPF5110-C-J WL058634 230V ASSEMBLY DRIVE UNIT, TOP DRIVE W/OPT WSTPF5111-C-J WL055691 ASSEMBLY, TOP FRONT RAIL WL055690 ASSEMBLY, TOP REAR RAIL WL055612 ASSEMBLY, REAR RAIL DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 28
WHEATON® Standard Roller Apparatus FIGURE B – MAIN ASSEMBLY 86 POS TOP DRIVE STANDARD ROLLER – WSTPF811X-A-J DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 29
230V ASSEMBLY DRIVE UNIT, TOP DRIVE W/OPT WSTPF8111-C-J WL058588 ASSEMBLY 120V WSTPF8110-A-B WL058607 ASSEMBLY 120V WITH OPTION WSTPF8111-A-B WL058590 ASSEMBLY 230V WSTPF8110-C-J WL058608 ASSEMBLY 230V WITH OPTION WSTPF8111-C-J DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 30
WHEATON® Standard Roller Apparatus FIGURE C – ASSEMBLY, BASE WITH UPRIGHTS – WL055693 DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 31
CASTER 3.5 IN. NON-MARKING WITH BRAKE 50030016 1/4-20 X 5/8 IN., BOLT I052363 1/4-20 X 1/2 IN., BOLT I052370 WASHER, STAR, 1/4 IN., INTERNAL TOOTH WI056888 UNIVERSAL UPRIGHT DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 32
WASHER, STAR, 1/4 IN., INT. TOOTH I052363 1/4-20 X 1/2 IN., BOLT 50030016 1/4-20 X 5/8 IN., BOLT 50027727 1/4 X 5/8 IN. WASHER I052860 RAIL, LEFT UPRIGHT I052859 RAIL, RIGHT UPRIGHT DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 33
FIGURE E – ASSEMBLY, FRONT RAIL – WL055613 FIGURE E – ASSEMBLY, FRONT RAIL – WL055613 ITEM QTY. DWK NO. DESCRIPTION WL055617 RAIL, FRONT SUPPORT WL055615 BEARING, SLOTTED DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
Page 34
WHEATON® Standard Roller Apparatus FIGURE F – ASSEMBLY, FRONT RAIL – WL055704 FIGURE F – ASSEMBLY, FRONT RAIL – WL055704 ITEM QTY. DWK NO. DESCRIPTION WL055684 RAIL, FRONT WL055615 BEARING, SLOTTED DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...
EU - Directive, with respect to the design and construction of the commercialized version. This declaration is invalid if modifications are performed on the device which has not been certified by DWK Life Sciences LLC. Designation of the device: Standard Roller...
Page 55
WEEE guidelines established in your area. There are no reusable parts. Contact the original distributor from which this product was purchased for proper disposal instructions. Specifications subject to change without prior notice. ã2021 DWK Life Sciences LLC DWK Life Sciences | 856.825.1100 | www.dwk.com | P/N 50099786 Rev. 11/2021...