ECOALLIANCE DYNAHEAT ECO-155LE Owner's Manual

ECOALLIANCE DYNAHEAT ECO-155LE Owner's Manual

Heat pump water heater
Hide thumbs Also See for DYNAHEAT ECO-155LE:

Advertisement

Owner's Manual
DYNAHEAT
HEAT PUMP WATER HEATER SERIES
2020.1
Model Numbers:
ECO-155LE
ECO-260LE
This appliance is not to be used by persons (including children) with reduced physical sensory or mental
capabilities; or lack of experience and knowledge, unless they have been given supervision and/or
instruction.
1

Advertisement

Table of Contents
loading

Summary of Contents for ECOALLIANCE DYNAHEAT ECO-155LE

  • Page 1 Owner’s Manual DYNAHEAT HEAT PUMP WATER HEATER SERIES ™ 2020.1 Model Numbers: ECO-155LE ECO-260LE This appliance is not to be used by persons (including children) with reduced physical sensory or mental capabilities; or lack of experience and knowledge, unless they have been given supervision and/or instruction.
  • Page 2: Table Of Contents

    Contents Introduction .............................. 3 How it works ............................. 3 Safety Precautions ........................... 4 Installation details ............................. 8 Trouble Shooting Guide ..........................9 Removing Air from the System ....................... 10 Electrical Connections ..........................10 System Operation Outline Continuous Power ..................10 System Operation If Connected To Off Peak Electricity ................
  • Page 3: Introduction

    Introduction The DynaHeat heat pump water heater system has been designed using the latest refrigeration ™ technology to remove the heat from the air to heat water. The refrigerant we use is R410a which does not contribute to global warming, so it allows us to help keep a clean, healthy earth for future generations.
  • Page 4: Safety Precautions

    Safety Precautions Please ensure you fully observe the precautions The following instructions need to be fully followed to prevent any harm to users and others or damage to your property. The extent of the possible harm or damage caused by misuse of the product falls into the following •...
  • Page 5 Warning Do not use any damaged, altered or bundled Verify that the piping has all been insulated. power chords. Any of the pipes freezing up and getting damaged could result in scalding or water leaking. Please contact the dealer on insulating the pipes. Ensure the product is removed from any gas Do not disassemble, repair or alter the product in containers, sources of fire and flammable...
  • Page 6 Caution Do not climb or put anything on top of the unit. Do Do not use the heat pump unit if the installation not apply any force to the piping. blocks have been damaged. Could result in injuries from a Damaged installation fall or being scalded.
  • Page 7 Caution Do not use the shower or any hot water for at When using the emergency water valve, first least one minute after recovery from a power cut. verify the temperature of the hot water and ensure you use a heat resistant collection vessel. Hot water may unexpectedly exit from the Hot water will be...
  • Page 8: Installation Details

    Installation details This Eco Alliance DynaHeat hot water heat pump system must be installed by a licenced person in ™ consideration of the following standards and regulations: AS/NZS3500 National plumbing and drainage code hot water supply systems – acceptable • solutions.
  • Page 9: Trouble Shooting Guide

    Trouble Shooting Guide Should a problem arise while the heat pump is in use, please check the following things prior to calling for support: STATUS POSSIBLE CAUSES ACTION TO TAKE Small or no hot water is left in Stop using hot water and wait for about an •...
  • Page 10: Removing Air From The System

    Removing Air from the System The following steps must be taken to ensure all air is removed from the system. Incorrect removal • of air may cause the water temperature to vary. Plumb pipes to the tank unit and the heat pump unit. •...
  • Page 11: System Operation If Connected To Off Peak Electricity

    System Operation If Connected To Off Peak Electricity There are no special settings for the off-peak connection. The system will run once the power • becomes available and the temperature in the tank drops below the set point of the tank thermistor. If connecting the unit to off-peak, ensure that the off peak tariff provides a minimum of 2 hours continuous power, as it can take at least 2 hours to fill the tank unit with hot water.
  • Page 12: Water Supply Quality

    Water Supply Quality Chloride and pH In high chloride water supply areas, the water can corrode some parts and cause them to fail. Where the chloride level exceeds 200mg/litre, warranty does not apply to the heat pump unit and tank unit. pH is a measure of whether the water is alkaline or acid.
  • Page 13: Technical Data

    Technical Data Heat Pump Unit Dimension Specifications: Refrigerant Type R410a Mass Volume 900g Running Ambient Air Temp C/+40 ◦ ◦ Setting Outlet Water Temp 35~60 C (1 C step) *1 ◦ ◦ Product Weight 30kg Thermal Capacity 3.6kw *2 Average Input Power 0.85kw *2 4.23 *2 Max Power Input...
  • Page 14: Hot Water Storage Tank Unit

    Hot Water Storage Tank Unit Refer drawing provided with tank: Water Tank Size Model No: ECO-155LE ECO-260LE A (Height) 1700 1760 B (Hot Water) 1455 1430 C (Cold Water Inlet) D (Diameter) Ø470 Ø560 E (Heat Pump Flow) F (Heat Pump Return) G (Sensor Port) H (PTR Valve) 1455...
  • Page 16: Wiring Diagram

    Wiring Diagram • 1) Transformer 10) Electronic expansion valve 2) Display 11) Water pump 12) Motor capacitance 3) Water tank temperature sensor 4) Exhaust temperature sensor 13) Electric machinery 5) Ambient temperature sensor 14) Four-way reversing valve 6) Gas recovery temperature sensor 15) Compressor 7) Coiler temperature sensor 16) Compressor start-up capacitor...
  • Page 17: Warranty Policy

    Warranty Policy Warranty Conditions The Eco Alliance Pty Ltd DynaHeat ™ heat pump water heater system must be installed in accordance with the installation instructions supplied with the DynaHeat heat pump water heater system and in accordance with all relevant ™...
  • Page 18: Eco Alliance Pty Ltd Contact Details

    In a commercial or industrial application, the warranty period on both DynaHeat heat pump water heater system ™ models are reduced to 12 months, parts only warranty. ECO Alliance Pty Ltd Contact Details 6 Braeside Drive, Braeside Vic 3195 +61 3 9512 0891 info@ecoalliance.com.au www.ecoalliance.com.au...

This manual is also suitable for:

Dynaheat eco-260le