General Information:

To provide an optimum service life, the valve should be operated only in its fully 
open  or  fully  close  position.  If  the  valve  is  used  in  partly  open  (throttled) 
position, seat life may be reduced. 
Extending  the  handle  lever  is  considered  misuse  and  can  damage  the  valve  or 
cause injuries. 
The valve body rating can be higher than the seat rating. 
High  viscous  or  abrasive  media,  frequent  operation  and  temperature 
fluctuations could cause an increase in valve torque. 
Valve pressure varies under different models, sizes, working temperatures and 
materials. Please verify the application within the limits specified herein and as 
described  on  metal  plate  spot  welded  on  valve  body.  References  contained  in 
this  documents  to  the  'PED"  are  in  regards  to  European  Pressure  Equipment 
Directive 97/23 EC. 
Always  use  Trueline  recommended  spare  parts  for  maintenance  and 
replacement.  

Shipping and Storage:

All  valves  are  packed  in  strong  cardboards  and  plastic  bags  to  avoid  any  possible
damage during transportation. All the valves must be examined on reception, to ensure 
that  they  have  not  suffered  any  damages  during  transport,  and  the  supplier  must  be 
informed  of  any  damages  observed.    If  the  items  are  not  for  immediate  use,  please 
follow the following instructions: 
1. Leave the valves in fully open position. Never leave the valve in a partially open 
position. 
2. Always  keep  the  protective  covers  in  place  until  the  valve  is  ready  for 
installation. 
3. The  valves  should  not  be  unpacked  until  they  are  to  be  definitively  installed, 
except for purpose of inspection. After inspection they will be packed again. 
4. The  valves  should  be  stored  under  cover  and  protected  from  severe  weather 
conditions and foreign bodies. 
5. Stainless  steel  ball  valves  do  not  need  any  additional  protection  coatings  once 
they are installed. 
6. Valves  to  be  stored  for  a  long  period  of  time  should  be  inspected  by  QC 
personnel every six months and every three months for automated valves. 
Trueline Distribution
20201 Clark Graham, Baie D'Urfé,
H9X 3T5 CANADA
P. : (514) 457-5777 T.F. : (800) 667-4819
F. : (514) 457-1348
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fig.652 and is the answer not in the manual?

Questions and answers

Summary of Contents for Trueline Distribution Fig.652

  • Page 1 Fig.652 Installation & Maintenance Manual General Information: • To provide an optimum service life, the valve should be operated only in its fully  open  or  fully  close  position.  If  the  valve  is  used  in  partly  open  (throttled)  position, seat life may be reduced.  • Extending  the  handle  lever  is  considered  misuse  and  can  damage  the  valve  or  cause injuries.  •...
  • Page 2 Fig.652 Installation & Maintenance Manual General Installation Step: The  handling  and  transporting  of  the  valves  must  be  carried  out  with  extreme  precaution  and  using  the  necessary  &  adequate  means  on  the  basis  of  their  size  and  weight, avoiding any risks to the person that handle them.  1. Valve pressure varies under different valve series, sizes, application temperature  and the material of the main parts. Please verify the application within the limits ...
  • Page 3 Fig.652 Installation & Maintenance Manual Preventive Maintenance: Preventive  maintenance  operations  essentially  consist  of  periodic  inspections  to  ensure that the valve is working properly.    1. The valve must be opened and closed at least once every six months. The user  will be responsible for establishing opening and closing plans that are adequate  for the working conditions and fluids used.  2. Before making the maintenance, always make sure the pressure is released and  the line has been closed.  3. Wear  protective  clothing  adequate  for  the  circulating  fluid.  (Comply  with  the  safety guidelines laid down by the company).  4. If leakage happens at the stem, tighten the stem nut a quarter turn as a routine ...
  • Page 4 Fig.652 Installation & Maintenance Manual Assembly: 1. Clean each component with a clean cloth.  2. Lubricate the thrust washer and stem packing. Insert the stem into the stem port  of  the  valve  body.  Place  the  threaded  end  perpendicular  to  centerline  of  the  body.  3. Hold  the  stem  up  and  insert  the  thrust  washer,  O‐Ring,  Stem  packing,  gland  packing, tab washer and gland (stem) nut.  4. Tighten the stem nut according to the torque specification stated in this manual. ...

Table of Contents