Sanique S-9 Electric Sanitising Sprayer CAUTION This manual contains important warnings and information PLEASE READ & KEEP FOR FUTURE REFERENCE VERSION S9-01-0420 Sanique 2b Stephenstown Industrial Park, Balbriggan, County Dublin, Ireland Declares that the Sanique S-9 Electric Sanitising Sprayer is in compliance with the regulations included in:...
The information on this page is intended only as a quick guide. It is no way intended as a substitute to the information on the pages following, which the user should be fully acquainted with before using a Sanique sanitising sprayer. SYMPTOM...
Page 4
USE TO SPRAY Most sprayable disinfectants and other sanitising fluids PERFORMANCE Flow 2.9 ltr/min 3000 psi SPECIFICATION Motor 1300 watt Weight 34.85 kg (complete) Warranty 2 years SUPPLIED COMPLETE WITH Sanitising spray gun Sanitising spray lance Gold sanitising atomisation tip 1/4”...
Page 6
WARNING! Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire and / or serious personal injury. The term Sanique sprayer in all of the warnings listed below refers to your mains-operated (corded) sprayer.
+ Have your Sanique sprayer serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the sprayer is maintained. If the supply cord of your Sanique sprayer is damaged it must be replaced by a specially prepared cord available through the service organization.
Page 8
MEDICAL ALERT INJECTION INJURIES If any solution appears to penetrate your skin, GET EMERGENCY MEDICAL CARE AT ONCE. DO NOT TREAT AS AN ORDINARY CUT. High pressure fluids from spray or leaks are powerful enough to easily penetrate the skin and cause extremely serious injection injury, leading to the possible need for amputation.
Page 9
NEVER LEAVE SPRAYER UNATTENDED WITH PRESSURE IN THE SYSTEM. FOLLOW PRESSURE RELIEF PROCEDURES AT ALL TIMES. ALWAYS INSPECT SPRAYING AREA + Keep the spraying area free from obstructions. + NEVER keep flammable material in spraying area. + NEVER spray in vicinity of open flame or other sources of ignition. + The spraying area must be at least 6 metres away from spray unit.
PACKINGS The packings are a wearing part. If your Sanique sprayer can no longer maintain pressure, has difficulty priming and tightening the packing nut no longer helps, then the packings will require replacement. This is best entrusted to a qualified...
Disengage the gun safety latch and you are ready to spray. PRESSURE RELIEF PROCEDURE IMPORTANT! To avoid possible serious body injury, always follow this procedure whenever your Sanique sprayer is shut off, when checking it, and whenever you stop spraying. Engage the gun safety latch.