Advertisement

Quick Links

NOTES OF OPERATION OF THE TOOL
MULTITEX3
13/06/11
Pag. 1
Multitex3
This document is property of I.L.E.

Advertisement

Table of Contents
loading

Summary of Contents for ILE MULTITEX3

  • Page 1 NOTES OF OPERATION OF THE TOOL MULTITEX3 13/06/11 Pag. 1 Multitex3 This document is property of I.L.E.
  • Page 2: Table Of Contents

    Instruction for installation.........................17 Instructions for the assemblage of the optic head................20 Instructions for assembly of magnetic sensor...................21 Instructions for regulation of instrument ..................22 Explanation of error messages......................23 Adapter Contex to Parallel........................24 13/06/11 Pag. 2 Multitex3 This document is property of I.L.E.
  • Page 3 Introduction The instrument Multitex3 is used on circular knitting machines for two main purposes: 1. Count the Piece rolls and perform some tasks related to the machine control 2. Check the fabric quality and perform tasks related to quality assurance...
  • Page 4 • Service Output 2A 250V. • A secret code can protect set up and data . • Work on loom speeds from 10 to 70 turns per minute. • Languages Italian, English, Francaise. 13/06/11 Pag. 4 Multitex3 This document is property of I.L.E.
  • Page 5: Main Unit

    The Couples of key '+' and '-' put on the right are used to adjust the sensibility of the related light • bar , one for Holes sensibility and one for Broken Meshes sensibility , for each optic scanner. 13/06/11 Pag. 5 Multitex3 This document is property of I.L.E.
  • Page 6: More Details On 'Initial Page' And Count Related Functions

    There is also a '*' in the upper line of the display when the instrument receive signal from the magnetic sensor. The Key 'Shift' changes the working shift to the next of T1, T2, T3, T4, T5. 13/06/11 Pag. 6 Multitex3 This document is property of I.L.E.
  • Page 7: Other On Initial Page And Optic Scanner Functions

    In some software version the position of the discarded needle is automatically detected and it is not required to be placed at the magnetic sensor . Anyway it is important that the Jump is enabled only if the discarded needle really exist on the fabric. 13/06/11 Pag. 7 Multitex3 This document is property of I.L.E.
  • Page 8 The value of reference is different from '0.' • The control of the tolerance is performed on the average of 5 turns and it attends some turns to the starting. 13/06/11 Pag. 8 Multitex3 This document is property of I.L.E.
  • Page 9: Function Of 'Precision Stop

    At the end of the last turn the stop can be further delayed as planned in the special page '10' “AT PIECE END” 13/06/11 Pag. 9 Multitex3 This document is property of I.L.E.
  • Page 10: Function Of Data Output On Serial Port Rs232

    N = normal A= Stop for other cause AUX1 N, 1 N = low 1= high, active AUX2 N, 2 AUX3 N, 3 AUX4 N, 4 AUX5 N, 5 AUX6 N, 6 Working shift T1,T2,T3,T4,T 13/06/11 Pag. 10 Multitex3 This document is property of I.L.E.
  • Page 11 The inputs for sensor LFAs from P1 to P4 are suitable for sensory placed on feeders type MPF20 or MPF10 or MPF--L; the last entry 'P5' it is suitable for sensory placed on feeder 'MER-C10' used for the Lycra. 13/06/11 Pag. 11 Multitex3 This document is property of I.L.E.
  • Page 12: Detailed Instructions

    Such 'Timer' it begins to count after the last impulse of the turns magnet , and it stops the machine when it reaches zero. Varying such delay the machine can be stopped in the wanted point. 13/06/11 Pag. 12 Multitex3 This document is property of I.L.E.
  • Page 13 Pressing the key 'Page' the shown value is assumed as reference value. One 'P' appear to point out this. Pressing the key goes to other LFA traces . LFA 2..5 As above but for the other LFA traces named P2... P5 13/06/11 Pag. 13 Multitex3 This document is property of I.L.E.
  • Page 14 Important note : Some version of the instrument does not show all of the pages above described, because some functions and related pages are substituted and integrated in the versions sequence. 13/06/11 Pag. 14 Multitex3 This document is property of I.L.E.
  • Page 15: Foreman Password

    '←' goes to other digit. Press the key 'Page' to confirm the password. PASSWORD Tx As the preceding page but for the shift from 2 to 5 . 13/06/11 Pag. 15 Multitex3 This document is property of I.L.E.
  • Page 16: Safety Maximum Speed Check

    It is up to the system integrator to set the dip-switch at the proper value for each textile machine . The dip-switch 4 is used for the LFA function as described in the related pages. 13/06/11 Pag. 16 Multitex3 This document is property of I.L.E.
  • Page 17: Instruction For Installation

    Note 2 : serial port RS232 use standard Personal computer pin-out for DB9 connector, which is pin 3 = TX, pin 5 = GND. Can be connected to every PC serial port using a standard cable null-modem 9-9 . 13/06/11 Pag. 17 Multitex3 This document is property of I.L.E.
  • Page 18 13/06/11 Pag. 18 Multitex3 This document is property of I.L.E.
  • Page 19 13/06/11 Pag. 19 Multitex3 This document is property of I.L.E.
  • Page 20: Instructions For The Assemblage Of The Optic Head

    4. Check that the fans don't make to tremble the cloth at their passage. This could cause some stop not necessary. 5. At this point it is advisable to install the magnetic sensor as described in the following pages . 13/06/11 Pag. 20 Multitex3 This document is property of I.L.E.
  • Page 21: Instructions For Assembly Of Magnetic Sensor

    The magnetic sensor is always used for the dropped stitches / ladder detection. This instrument use only one magnetic sensor even if there are two optic heads/scanners. 13/06/11 Pag. 21 Multitex3 This document is property of I.L.E.
  • Page 22: Instructions For Regulation Of Instrument

    Just remember to enable the jump of the discarded needle with the 'Jump' key, if needed, and to set up the various parameters as described in the specific installation. 13/06/11 Pag. 22 Multitex3 This document is property of I.L.E.
  • Page 23: Explanation Of Error Messages

    The discarded needle it is not present in the loom nor in the fabric. In such case disable the jump • with the key 'Jump', the yellow light has to be turned out to confirm that the jump is disabled. 13/06/11 Pag. 23 Multitex3 This document is property of I.L.E.
  • Page 24: Adapter Contex To Parallel

    Built-in test – serial port receive correct messages Built-in test – serial port receive data Speed bit0 Speed bit1 Speed bit2 Speed bit3 Speed bit4 Speed bit5 Speed bit6 Power supply present 13/06/11 Pag. 24 Multitex3 This document is property of I.L.E.
  • Page 25 The two pins at the beginning of the connector labeled with 'M' are connected to Ground. Outputs are open-collector stile as follows : Maximum current is 100mA , maximum voltage is 16V. 13/06/11 Pag. 25 Multitex3 This document is property of I.L.E.

Table of Contents