Download Print this page
PELEKIS INTD0909 Reference Manual

PELEKIS INTD0909 Reference Manual

Gsm gateway voice / data

Advertisement

Quick Links

GSM Gateway INTD0909
Page 2
Page 3
Page 4
Page 5-6
Page 7-12
Page 13-27 Programming
Pages 21-27 iOS / Android mobile Application
Page 28-30 Record Function
Please read carefully the instructions in order to
get all the benefits of this device.
voice / data
Firmware Revision
General Description - Features
Specification
Wiring-Connection
Operation Mode
Reference Manual
www.pelekis.tech
Rev. 1.04
April 2019

Advertisement

loading

Summary of Contents for PELEKIS INTD0909

  • Page 1 Reference Manual GSM Gateway INTD0909 voice / data  Page 2 Firmware Revision  Page 3 General Description - Features  Page 4 Specification  Page 5-6 Wiring-Connection  Page 7-12 Operation Mode  Page 13-27 Programming  Pages 21-27 iOS / Android mobile Application ...
  • Page 2 04/2016 Add Record voice messages.  v1.02 06/2017 Selection between PSTN and GSM line, enabled  v1.03 07/2017 4 SMS programmable number enabled  v1.04 04/2019 iOS / Android Application programming method added PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 3: General Description

    Combined with every Intelco Emergency phones, ensures bidirectional com- munication for both trapped passenger and service personnel. The GSM gateway INTD0909 has a 6.3V integrated backup battery and can oper- ates up to 6 hours in case of AC failure. All GSM functions can be programmed remotely by SMS messages.
  • Page 4: Specifications

    8 inputs / 8 Outputs 0-80°C Operation temperature 10-80% (non condensing) Operation humidity 60 x 210 x 145 mm (H x W x D) Dimensions (External) Weight (Total/w Battery) 1Kg PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 5: Wiring Connection

    Connect the power cable to the terminal and plug it to the 230V AC. A red LED will light up near the 230V AC terminal. Make a short circuit at the jumper ―RESET‖ beside of the terminal BAT. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 6 Schematic 1. Fuse 100mA Power Battery (6,3V) Outputs RESET Inputs AC present Line LED Indication Battery Network INTELPHONE signal strength Net Status External Line SIM Card Bottom Side PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 7: Operation

    Functions with SIM Card detected:  Voice Ready  SMS Ready  Data Ready (Not Available)  Battery check Functions with SIM Card not detected:  Limited Voice Ready ( International Emergency Number (112))  Battery check PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 8 “LOW BATTERY-DEVICE IS SUTTING DOWN” outgoing SMS.  “BATTERY DESTROYED-PLEASE REPLACE” outgoing SMS.  Outgoing SMS for Inputs (Auto SMS=1).  Reset if SIM Card presents is lost.  Reset if Network signal is lost. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 9 If the connected line is terminated for any reason, the ―LINE‖ led turns off and immediately turns on/off according to the current earpiece Hook state.* Hook Off : “LINE” led = On — Hook On : “LINE” led = Off PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 10 Program Incoming call function Program SIM Card notifications  Ask monitor  Program Outputs-Relays.  Program Inputs-Optocouplers. Action not ready — Send answer but has no effect on device. Action not available — Send no answer. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 11 “LOW BATTERY” Battery status below 65%  “SHUTTING DOWN” Battery status below 50% Caution : Battery status SMS function, will work only if ―Low Battery Number‖ is programmed and onboard SIM Card is detected. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 12 If the antenna disconnects during normal operation mode, device may cause a RESET event. Caution : If the signal strength is Weak you must move the antenna in order to find a better signal, consulting the leds. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 13 When GSM device manage the Call Progress operation then several Call tries should be conducted until a reliable connection established to the first available Rescue Service number. Available programming ability is fully described on Redphone manual (INTD0900). PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 14 GSM Gateway device that defines its operation. SMS programming method requires credits for SMS messages on the SIM Card. The exactly programming method is described in depth on SMS Programming Table at page 15. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 15 ‗ * ‘ : All commands must close with ‗ ? ‘ : Ask the content of variable. ‗ # ‘ : Change parameter field. ‗ , ‘ : Change scope of variable if more than one Ex.( #0000#7#R1=1,r8:0,r7=0,r1=0* ) PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 16 This command stores up to one (1) telephone number that device will notify in case of low battery or battery failure. In this command there is Edit-Delete and Ask possibility. Edit-Delete Edit: #0000#2#69782136554 Delete: #0000#2#_ Ex.: #0000#2#? PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 17 In Battery failure or shelf test operation, device informs for its state with the onboard loud buzzer. In this command there is only Edit and Ask possibility. Edit Buzzer ON: #0000#4#1 Buzzer OFF: #0000#4#0 Ex.: #0000#4#? PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 18 In this command there is only Edit and Ask possibility. Edit Enable: #0000#5#1 Disable: #0000#5#0 Ex.: #0000#5#? User Command 6 - “Ask monitor” : This command is not enabled yet for the user. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 19 This function is called ―Auto‖ and can be enabled or disabled according the program sequence bellow. In this command there is only Edit and Ask possibility. Edit Auto ON : #0000#8#1 Auto OFF : #0000#8#0 Ex.: #0000#8#? PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 20 This command returns the IMEI number of the GSM device. In this command there is only Ask possibility. Ex.: #0000#23#? Admin Command 24 - “SIM Card notifications” : This command is not enabled yet. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 21 At this section we are going to see how the Application works and what are the available features that it offers. The first step is to get the ―Pelekis GSM Configurator‖ Application installed on our mobile device. User can easily locate and install the application from the AppleStore or Playstore respectively to him device.
  • Page 22 On the main screen of the Application user should add the telephone number of the SIM card that has been previously installed and activated in the GSM Gateway (INTD0909) device that he is trying to program. In order to do this, user must place the telephone number in the textbox that appears in the middle of the screen.
  • Page 23 To do this user should add from 1 to 4 numbers in the textbox and then press the ―Send Message‖ button located on the bottom of the screen. User can directly chose an number from his contact list and the same way as done before. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 24 To do this user should add 1 telephone number in the textbox and then press the ―Send Message‖ button located on the bottom of the screen. User can directly chose an number from his contact list and the same way as done before. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 25 SMS Inbox informing the user about the status of both relays. NOTE ! Making the Get Status action will not update the user interface with the current status of the device‘s Relays. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 26 Auto Mode label. After editing the status of the Auto Mode switch user should press the ―Send Message‖ button in order to program the GSM Device with this functionality. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 27 GSM Device, so deleting a record from this list mean also the loss important data of a GSM Device. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 28: Record Function

    Call Rescue Number Rescue Service Answered ― E.g. Emergency Call! Trapped person at UCL, Gower St, Play London WC1E 6BT, United Voice Message 2 Kingdom ‖ (For rescue service) Finish Playback Full Communication PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 29 Exiting the record process will determine if the recorded message will be enabled or disabled. Keys Function “1” Start and Stop Record “2” Play Recorded message “*” Enable Message Playback - Exit “#” Disable Message Playback - Exit PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 30 Pressing and releasing the Key ―#‖ device will return two(2) short sounds. The above Disables the current ―Voice Message‖ even if it is an empty message. In this way, device also exits the record function and get GSM Gateway back in normal operation. PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...
  • Page 31: Technical Support

    For technical support for this product, contact the local distributor or Intelco Electronics. Intelco Electronics Contact Info : Tel. :+30 210 23 23 345 Fax :+30 210 23 86 382 E-mail : service@intelco.com.gr Website : www.intelco.gr PELEKIS ELECTRONICS ISO9001/2015 Rev. 1.04 April 2019...