Charging the bracelet ........................10 USING YOUR BRACELET WITH A SMART DEVICE ..............12 Download and install the free “CARDIOMOOD” app onto your smart device........ 12 First time use ..........................12 Pairing Your Bracelet with a Smart Device ..................12 Troubleshooting the Bluetooth Connection ..................
This instruction manual provides you with important information about the CardioMood 287 CardioWatch Bracelet. To ensure the safe and proper use of this bracelet, READ and UNDERSTAND all of the safety and operating instructions. If you do not understand these instructions or have any questions, contact info@cardiomood.com before attempting to...
• To help avoid strangulation, keep the charger cable away from infants, toddlers or children. • This product contains small parts that may cause a choking hazard if swallowed by infants, toddlers or children. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
• DO NOT drop or subject this bracelet to strong shocks or vibrations. • DO NOT use this bracelet with other medical electrical (ME) equipment simultaneously. This may result in incorrect operation of the bracelet and/or cause an inaccurate reading. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
DO NOT place it under heavy objects. • Wipe any dust off of the charger. • Unplug the charger when not in use. • Unplug the charger before cleaning this bracelet. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Federal Communications Commission Indicates a product should not be disposed of in a landfill; the black bar indicates that the equipment was manufactured after 2005 CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
6.1 Front of the bracelet (A) Ambient Temperature Sensor (B) LEDs (C) Pusher button 6.2 Back and bottom of the bracelet (D) Temperature Sensors (E) PPG Sensor (F) Magnets (G) Charge Contacts CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Attach the charger cable to the backside of the bracelet. The magnets will pull the charger head to the bracelet. The Magnets will click the charger into position. The LEDS will light up to indicate that charging has started. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Page 11
The polarity of the magnets in the bracelet and the charger will ensure that the charger contacts will align. Pattern State Green (B1) Flashing Bracelet charging Bracelet fully charged Green (B1) or not on charger CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
7 USING YOUR BRACELET WITH A SMART DEVICE 7.1 Download and install the free “CARDIOMOOD TRENDS” app onto your smart device. The “CARDIOMOOD TRENDS” app is available in the App Store and Google Play. Minimum requirements for use of the app: • iOS: version 12.2 or higher...
Page 13
Press on button in the app to start After button is pressed app will look for pairing. the bracelet CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Page 14
10 seconds and then turn it OFF. When your bracelet is connected successfully to your smart device, the green “V” symbol appears under Settings: CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
If none of the above did not resolve, you will need to re-pair your bracelet: 1. Go to watch settings: Remove/Clean old pairing 2. Go to Bluetooth settings, find 287, 286, 284 > Click Forget Device/Unpair 3. Force quit the app on your phone 4.
If none of the above did not resolve, you will need to logout and login again to the cloud: 1. Go to profile settings and log out 2. Force quit the app on your phone 3. Re-open the app 4. Enter user and password 5. Follow instructions CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
9 PREMIUM SERVICE The CARDIOMOOD TRENDS app will offer Preventicus Heartbeats in future as a Premium Service. User needs to select a plan: CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Preventicus Heartbeats should not be used for decision-making in life-threatening situations or for real-time monitoring of vital functions nor should it intervene with existing diagnostic pathways or therapeutic measures according to the guidelines. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
10.7 Reading and accepting the purpose, including warnings, Terms and Conditions and Privacy Policy Please read the Terms and Conditions carefully and accept them to continue: CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Page 24
PDFs will go into an be collected in the section <<My Reports & Notifications>>. In addition, a queue displays the recent five active measurements or irregular • sequences recorded passively. Tap for details and PDF. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
(tachycardia/bradycardia). If you are not under medical observation and if this occurs repeatedly, it is imperative you see the cardiologist immediately. Table 8.8.1 Preventicus Heartbeats color coded results CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Fig. 8.9.1/section 2, are normal and are usually caused by the interaction between breathing and heartbeat. Sudden positive or negative peaks, as shown in Fig. 8.9.2, however, are caused by individual irregular heartbeats and may be evidence of extrasystoles CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Page 27
(such as extrasystole) and red R peaks an extremely irregular heartbeat based on absolute arrhythmia (suspected atrial fibrillation). Fig. 8.9.4 Legend of the R peaks in the original pulse curve CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Fig. 8.9.5 Original pulse curve of the measurement report with detected disruption (blue bar) 10.10 Measurement reportlist After each measurement, the reports are stored in a list and can be viewed via the menu item “My results”. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Page 29
You can then choose from a selection of services to send the report or store it on your smartphone outside of the app. You receive a message that encryption or password protection of the document is recommended when sending the report. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
The Telecare service will verify your measurement report. You will receive the result directly on your smartphone under Telecare reports. See the "Telecare reports" section for a sample report. Just like the measurement reports, you can also delete the Telecare reports. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Page 31
Telecare report from the list and go to the detailed view. Tap the “Share” button to subsequently receive a selection of services to send the report or store it on your smartphone outside of the app. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Several measurements: if you want to send several measurements at the same time, select "Send up to 5 measurements". Please note that you can only select abnormal measurements (red and yellow traffic lights). CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
11 HEALTH APP AND GOOGLE FIT INTEGRATION The CARDIOMOOD TRENDS app is integrated with the Apple Health and Google Fit apps. Information about your activities and vitals helps us provide you with a monthly (premium) personal report. You have the option of turning off the integration within the Apple Health and Google Fit apps;...
Heart Rate ................ +/- 3 BPM compared to ECG RR interval ................ +/- 50ms compared to ECG PPG sensor are exposed on the back of the CardioMood bracelet. The PPG sensor makes contact with the user’s skin. CardioWatch 287 Ι CardioMood S.A. Ι Revision status: 2...
Guidance and manufacturer's declaration - electromagnetic emissions The CardioMood Bracelet is intended for use in the electromagnetic environment specified below. The customer or the user of CardioMood Bracelet should assure that it is used in such an environment. Emissions test...
Page 36
Guidance and manufacturer’s declaration—electromagnetic immunity CardioMood bracelet is intended for use in the electromagnetic environment specified below. The customer or the user of CardioMood bracelet should assure that it is used in such an environment. Electromagnetic environment - Immunity test...
Page 37
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which CardioMood bracelet is used exceeds the applicable RF compliance level above, CardioMood bracelet should be observed to verify normal operation.
RF communications equipment and CardioMood Bracelet CardioMood Bracelet is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the CardioMood bracelet can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the CardioMood bracelet as recommended below, according to the maximum output power of the communications equipment.
Need help?
Do you have a question about the 287 and is the answer not in the manual?
Questions and answers