Attention: Before switching on the unit, leave it standing on its feet for 24 hours to ensure that the oils that may have been circulating during transportation have settled. The unit is then ready for start-up. WTG-Quantor GmbH Europa-Allee 53 D-54343 Föhren...
1. Safety instructions 1.1 Installation and commissioning Place the unit on a plain, dry and clean place. Before switching on the unit, leave it standing on its feet for 24 hours to ensure that the oils that may have been circulation during transport have settled. Pay also attention that the connecting cable is untangled and free and that nothing is resting on it.
1.2.1 Impairment of safety If the unit is damaged, it must be unplugged, set aside, marked to warn others against using it, and a technician must be called before it is returned to operation. Using the unit if it is damaged is unsafe and therefore stricktly prohibited. 1.2.2 Safety instructions The unit may only be operated after an appropriate protection earth has been connected, and the directions of the country of destination, regional regulations as well...
3. Commissioning 1) Remove the lid and fill the water tank with water (see water level gauge outside). Never operate the unit with a liquid level beneath the lowest water level mark “min”! 2) Connect the water pipes, check for possible leaks. 3) The unit is designed to operate with a tank temperature control kit which includes a submersible pump and plastic tubes to lead Glycol water through it.
3.2 Chart Example: MiniChilly 05 SB Comp Water level gauge and tank emptying Thermostatic controller Cover fastener Small pipes for water return flow Connections 3/8‘‘ Expansion valve Water tank Condenser Evaporator (cooling circuit)
4. Decommissioning Switch off the unit and disconnect the power plug. Remove the pipes/hoses from the unit. Draining and cleaning of the unit by qualified personnel. 5. Temperature setting Thermostatic operation: adjust the desired set-point temperature at the controller (5). Do not operate the unit when it is open with the lid removed! Make sure that the lid is fastened before switching the unit on! For ice bank building...
Page 8
The value you see on the diplay after starting the unit is the current water temperature 1. Press the button SET for 1 second (The set value will start flashing after a few moments) 2. Increase or decrease the value using the arrow button UP or DOWN 3.
6. Cleaning of the cooling unit Casing: Before cleaning the units disconnect the mains plug! Please do not use water directly on the unit, clean only with a wet cloth and a little dish liquid. The cleaning of the units and the beverage coils (optional for this unit, if used) have to take place according to the instructions of the industrial safety regulations.
Mobile on wheels 10. Declaration of conformity We, WTG-Quantor GmbH, D-54343 Föhren, declare in sole responsibility that the cooling units MiniCHILLY 05, MiniCHILLY 09 and MiniCHILLY 17 which this declaration refers to, comply with the following standards and normative documents.