ABBERFIELD C22 Series Technical & Service Details

Coin validator / controller

Advertisement

Quick Links

C22
C22 DESIGNATES:- COIN VALIDATOR USING THE 22 SERIES
PLASTIC MOULDINGS
The information detailed is 'generic' to cover the different
validator types. This literature primarily covers the C22P
validators. Suffixes may be added to cover specific
applications. More specific information is provided in the
technical notes for each of these applications.
TECHNICAL & SERVICE DETAILS
International Tel: +61-2 9939 2844 Fax: +61-2 9938 3462
A B B E R F I E L D
I N D U S T R I E S
P T Y L T D
ABBERFIELD INDUSTRIES PTY LTD
32 Cross Street, Brookvale, Sydney, NSW 2100 Australia
Tel: (02) 9939 2844 Fax: (02) 9938 3462
Email: contact@abberfield.com.au
Internet: www.abberfield.com.au
A B N 6 1 0 0 0 1 1 2 5 6 9
series
COIN
VALIDATOR /
CONTROLLER
Brochure # 083-3

Advertisement

Table of Contents
loading

Summary of Contents for ABBERFIELD C22 Series

  • Page 1 More specific information is provided in the technical notes for each of these applications. TECHNICAL & SERVICE DETAILS ABBERFIELD INDUSTRIES PTY LTD 32 Cross Street, Brookvale, Sydney, NSW 2100 Australia Tel: (02) 9939 2844 Fax: (02) 9938 3462 International Tel: +61-2 9939 2844 Fax: +61-2 9938 3462 Email: contact@abberfield.com.au...
  • Page 2: Coin Validator

    ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS page 2 Brochure # 083-3 C22 SERIES COIN VALIDATOR SPECIFICATION Up to 8 coins may be validated in the physical range 16 mm to 32 mm diameter and thickness to 3.5 mm. Coins are validated optically for a diameter measurement and washer detection, plus the rate of travel.
  • Page 3: Mounting Details

    ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS page 3 Brochure # 083-3 MOUNTING DETAILS Panel mounting is achieved by fitting the face plate on one side of the panel and the validator on the other. Slip fitting is possible with the addition of a mounting bracket to the bottom mounting screws.
  • Page 4 ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS page 4 Brochure # 083-3 CALIBRATION validator then scroll through the coins until C8 is on the screen. 11. Turn the power off. If recalibrating an existing Using the SET and NEXT push buttons, plus the 8...
  • Page 5: Adjusting Calibration

    ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS page 5 Brochure # 083-3 ADJUSTING CALIBRATION Coin Diameter Period Amplitude Minimum Maximum Minimum Maximum Minimum Maximum The normal calibration procedure is all that is Repeat steps 3 to 7 until all coins have been ever needed and the following information is recorded.
  • Page 6: Data Retrieval

    ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS page 6 Brochure # 083-3 PRICE ADJUSTMENT 2. If the Audit Log input is shorted twice in one second then the display will show the full data log including the Gross revenue since the unit TO PROGRAM COPY PRICES was installed.
  • Page 7: Error Mode

    ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS page 7 Brochure # 083-3 SERVICE ERROR MODE MAINTENANCE DISASSEMBLY Setting the 7th dip switch up to the ON position allows the display to show error messages for There are three active parts to the coin validator, each coin deposited.
  • Page 8 ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS page 8 Brochure # 083-3 OPERATING PROGRAMMES As well as validating coins the device can control other machines via a number of inputs and outputs. Special software programmes can be provided to meet specific industry or customer needs. Then the instruction label each side of the coin validator changes to satisfy the specific application.

Table of Contents