  • Page 2: Table Of Contents

    INDEX 1 For your safety................................2 2 Product specifications ............................4 3 Parts ..................................5 ① The control panel ............................5 ② Operation panel and instructions .......................6 ③ Function Description............................6 ④ Controller, terminal, temperature sensor ....................7 4 Setup ..................................7 ① Placing the unit .............................7 ②...
  • Page 3: For Your Safety

    1 For your safety! Please do not operate the unit before carefully reading and understanding the content of this section. The items treated in this section are to ensure safe use of the unit and to beforehand prevent harm or injury to you and others.
  • Page 4 Caution If the unit is not working properly, pull the plug Do not expose your body to the cold air from the unit immediately and turn it in for service or repair. for an extended period of time. **There is risk of electric shock or fire caused by a **Prolonged exposure can harm your health.
  • Page 5: Product Specifications

    **There is risk of electric shock and physical injuries. **Inadequate or poor handling can result in fire, malfunction and injuries. 2 Product specifications Model number YDH-3500 YDH-4500 YDH-5500 YDH-6500 Single phase Single phase Single phase Single phase...
  • Page 6: Parts

    3 Parts 1. The control panel Display Icon Description Refrigeration Icon 1. This icon will be fixed when compressor is working. 2. This icon will be flashing when compressor is not working 3. This icon will not be displayed when machine turn off. Wind Speed Icon 1.
  • Page 7: ② Operation Panel And Instructions

    2. Operation panel and instructions: Button Instruction of the buttons 1.A single button instruction: Conversion between power on and power off after you press each time; ON/OFF Adjust the different value in different condition: 1. Increase temperature setting value.(Range 17°-30°) ; ▲...
  • Page 8: ④ Controller, Terminal, Temperature Sensor

    System fault dropping, need to check the compressor and refrigerant gas. 4. Controller, terminal, temperature sensor: Terminal instructions: Marking Specification Model Introduction N1,N2 T6.3 Single insert The AC power zero input/output end. Relay COM T6.3 Single insert The ac power fire line input Relay N.O T6.3 Single insert The compressor output interface...
  • Page 9: ② Attaching The Cool Air Duct

    Make sure that the unit is placed so that there is nothing blocking the front side filter, the cool air duct or the hot air exhaust duct. There is only an air inlet on the front side, and the only air outlets are on the top, so the unit can be placed with the other sides directly against a wall, in a corner or in any other confined space.
  • Page 10 Note: ① If something is dropped into the exhaust air vent, do not use a stick or similar object to try to retrieve it. You may damage internal parts and cause malfunction. ② Do not block the exhaust air vent in any way. This will obstruct the function of the unit and cause malfunction.
  • Page 11: ③ Connecting To A Power Source

    Make sure that no other electrical appliance is connected do the same power source as the unit. (2)The circuit breaker Use a 10A(YDH-3500), 30mA ≤0.1sec. circuit breaker,15A for YDH-4500/5500/6500. (3)Connecting the unit to a power source Insert the plug into the power source.
  • Page 12: Safety Devices

    Note: ①The amount of condensed water that gathers in the drain tank varies depending on the temperature and humidity of the environment where the unit is used, as well as how clean or dirty the heat exchanger is. The amount of condensed water increases remarkably during rainy seasons and other times with high humidity, so be extra attentive at these times.
  • Page 13: ③ Before Storing The Unit

    3. Before storing the unit ① Clean the filter and the exterior of the unit. ② Empty the drain tank and let it dry completely. ③ Turn on “Ventilation” for approximately one hour to let the internal parts dry completely. ④...
  • Page 14: Troubleshooting

    9 Troubleshooting Important: To ensure safety, read section one “1 For your safety!” first. What’s wrong? What to check Measure Is there power supply? Turn the power switch to “STOP” until (The power could be off because the power is back on again. If the switch is of blackout etc.) turned to “COOL”...
  • Page 15: After Service

    10 After service Caution Please use standard parts for maintenance and repair. **If you use spare parts other than standard parts, there is risk that they will not fit properly and can cause malfunction or accidents. **The same condition applies also to the case if spare parts are used in products from other companies. ●...