Summary of Contents for YewdaleDefiant 980003

  • Page 1 Programming Instructions for YewdaleDefiant motors ® (980003) yewdale.co.uk Part no: 980003...
  • Page 2 Programming Instructions YewdaleDefiant 7.4v DC Solar Powered Tubular Motor (980003) ® with inbuilt radio receiver, transformer and electronic limit stop Applications: Application 1: Lithium Battery Power Application 2: Lithium Battery Power Solar Panel Charger 8.4DC 1.0A Built in lithium battery...
  • Page 3 First limit position setting: (If there’s no other action within 30 seconds. the motor will exit from the limit position preparation automatically) Press PROG on the Motor will shunt once Press UP adjusting the Press PROG on the Motor shunts once transmitter for 1 to indicate limit stop motor to the required...
  • Page 4 Programming Instructions YewdaleDefiant 7.4v DC Solar Powered Tubular Motor (980003) ® with inbuilt radio receiver, transformer and electronic limit stop Limit position fine tuning: (If there’s no other action within 30 seconds. the motor will exit from the limit position preparation automatically)
  • Page 5 Limit position setting: A maximum of six different limit stop positions can be set. The furthest two positions are called the UP and DOWN limit stop positions. The others are called the middle limit stop positions; When the first limit position is in the UP limit stop position (as below illustration), all other limit positions can only be set below this position;...
  • Page 6 Programming Instructions YewdaleDefiant 7.4v DC Solar Powered Tubular Motor (980003) ® with inbuilt radio receiver, transformer and electronic limit stop Add the new transmitter: Press STOP on the transmitter Motor will shunt once. Press UP on the new Motor shunts once again.
  • Page 7 Trouble Shooting: Items Problems Cause Solution 1. Connected with the wrong voltage 1. Change to the correct voltage After connecting power, 2. Overloading the motor doesn’t work 2. Choose suitable motor torque 3. Incorrect installation leading to or works slowly 3.
  • Page 8 Yewdale, Enterprise Way, Wickford, Essex SS11 8DH Call +44 (0)1268 570900 +44 (0)1268 732509 Email enquires@yewdale.co.uk Visit yewdale.co.uk For more information on all Yewdale products, please call the sales department. ® ® ® ® ® A comprehensive range The only fail-safe range of The industry’s preferred A dedicated range of privacy A concise approach to...