Sensia CLIF MOCK LGS-1 Installation, Operation & Maintenance Manual

Sensia CLIF MOCK LGS-1 Installation, Operation & Maintenance Manual

Sample pump

Advertisement

Quick Links

MEASUREMENT
CLIF MOCK™
LGS-1 Liquid and Gas
Sample Pump
Installation, Operation & Maintenance Manual
MODEL:
LGS-1
Manual No. 9A-99104500147, Rev. 02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLIF MOCK LGS-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sensia CLIF MOCK LGS-1

  • Page 1 MEASUREMENT CLIF MOCK™ LGS-1 Liquid and Gas Sample Pump Installation, Operation & Maintenance Manual MODEL: LGS-1 Manual No. 9A-99104500147, Rev. 02...
  • Page 2 LGS-1 Liquid and Gas Sample Pump Page Left Intentionally Blank...
  • Page 3 Important Safety Information Terms Used in This Manual Caution Caution, risk of electric shock Attention Attention, risque d'électrocution WARNING A warning identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. AVERTISSEMENT Un avertissement identifie des informations sur des pratiques ou des circonstances pouvant entraîner des blessures corporelles ou...
  • Page 4: Table Of Contents

    LGS-1 Liquid and Gas Sample Pump Table of Contents Section 1: LGS-1 Sample Pump Overview .................. 6 Description ................................. 6 Section 2: Specifications ......................7 Sample Specification ............................7 Sample Size ............................... 7 Section 3: LGS-1 Sample Pump Installation ................8 Air Supply ................................
  • Page 5 WARNING! To avoid the risk of electric shock and fire, the following safety instructions must be observed and the guidelines followed. The specifications must not be exceeded, and the device must only be applied as described in the following. Prior to the installation and commissioning of the unit, the installation guide must be GENERAL examined carefully.
  • Page 6: Section 1: Lgs-1 Sample Pump Overview

    LGS-1 Liquid and Gas Sample Pump Section 1: LGS-1 Sample Pump Overview DESCRIPTION The LGS-1 Sample Pump is a pneumatically operated positive displacement pump designed to transfer samples of liquid or gas into a vented sample receiver or into a pressurized cylinder. The sampling cycle begins with a signal being sent from the controller circuitry to the solenoid which diverts instrument or plant air to the sample pump drive piston.
  • Page 7: Section 2: Specifications

    0.25 cc to 1.25 cc for liquid applications. The default factory setting for sample size is 0.5 cc at 300 psi using gas. Calibration is available when operating conditions are supplied by the customer. If an application requires sample volumes outside the standard ranges, contact Sensia.
  • Page 8: Section 3: Lgs-1 Sample Pump Installation

    LGS-1 Liquid and Gas Sample Pump Section 3: LGS-1 Sample Pump Installation AIR SUPPLY The LGS-1 sample pump is actuated by an air supply. In gas applications, the line pressure is often sufficient to actuate the pump. But in liquid applications and some low-pressure gas applications, air must be supplied externally.
  • Page 9: Tubing Connections

    Section 3: LGS-1 Sample Pump Installation Figure 2: Pump actuation (air) pressure chart TUBING CONNECTIONS Tubing arrangements will vary, depending on the product sampled (gas or liquid). At a minimum, ¼-in. stainless steel tubing will be required to connect the air supply from the controller to the sample pump. A ¼-in.
  • Page 10: Fast Loop Considerations

    LGS-1 Liquid and Gas Sample Pump FAST LOOP CONSIDERATIONS Under some flow conditions, a fast loop plumbing arrangement may be preferred to ensure that only fresh liquid flow is sampled. This configuration requires an orifice plate, flow straightener, or other flow obstruction in the pipeline to cause a small differential pressure to ensure that the sample probe collects fresh fluid with each sample grab.
  • Page 11: Section 4: Setting Sample Size

    Section 4: Setting Sample Size Section 4: Setting Sample Size Sample size is set by adjusting the knob at the top of the sample pump to a predetermined height (“h”) above the flat surface of the pump. The height measurement required directly corresponds to the sample size desired.
  • Page 12 LGS-1 Liquid and Gas Sample Pump 2. Locate the desired line pressure in the chart “CC” column of the Gas Measurement chart and note the corresponding height (h) value. Find the value (h) that corresponds to the desired sample size and line pressure.
  • Page 13: Section 5: Lgs-1 Sample Pump Maintenance

    Section 5: LGS-1 Sample Pump Maintenance Section 5: LGS-1 Sample Pump Maintenance SAMPLE PUMP COMPONENTS Refer to Figures 6 and 7 as well as Tables 1 and 2 when performing the procedures in this section. The pump is essentially maintenance-free. Change O-rings annually under routine operating conditions. If operating in a severe environment, inspect O-rings more frequently and replace, as necessary.
  • Page 14 LGS-1 Liquid and Gas Sample Pump RING, RETAINING K-2 300-62-SS2 O-RING #011 VITON POPPET, CHECK, LGS-1 BODY INLET, LGS-1 O-RING, VITON, #008 SEAT, LGS-1 15** SPRING, COMPRESSION CHECK, LGS-1 RETAINING RING, EXTERNAL RETAINER, FILTER BASKET 18** SPRING, SEAT, COMPRESSION, LGS-1 GUIDE, CHECK SPRING O-RING, VITON, #110 #8-32NCx3.5"...
  • Page 15: Sample Pump Disassembly

    Section 5: LGS-1 Sample Pump Maintenance Table 2: Purge Valve Assembly Components Item Description Qty. VALVE, PURGE SEAT, VALVE LGS MANIFOLD NUT, BONNET LGS MANIFOLD O-RING, BUNA-N #013 O-RING, VITON #007 STEM, VALVE LGS MANIFOLD HANDLE, VALVE LGS MANIFOLD SCREW, FILISTER HD SLT 8-32 X 5/16 SS * These items are contained in the Seal Kit listed in the Spare Parts list.
  • Page 16: Housing Disassembly

    LGS-1 Liquid and Gas Sample Pump Bodily injury could result. If you cannot evacuate the sample chamber gases after repeated attempts, contact Sensia for further instruction. HOUSING DISASSEMBLY 1. To continue disassembly of the pump, remove the four (4) screws (item #21) from the purge valve (item #35).
  • Page 17: Purge Valve Disassembly

    Section 5: LGS-1 Sample Pump Maintenance 4. Carefully remove the sample chamber assembly (item #23) and the seat assembly from the inlet body. a. To accomplish this, use a flat punch and gently apply pressure to the check poppet (item #11) stem. b.
  • Page 18: Inlet Body Assembly

    LGS-1 Liquid and Gas Sample Pump 4. Install the seat (item #2*) into the purge valve (item #1*). 5. Install the bonnet nut (item #3*) into the purge valve (item #1*). 6. Install the handle (item #7*) and the screw (item #8*) to the stem (item #6*). 7.
  • Page 19: Housing Assembly

    Section 5: LGS-1 Sample Pump Maintenance 7. Remove the set screw and adjustment knob to place the washer (item #3) and nut (item #2) on the adjustment screw. Replace the set screw and adjustment knob on to the adjustment screw. 8.
  • Page 20: Section 6: Spare Parts List

    LGS-1 Liquid and Gas Sample Pump Section 6: Spare Parts List A seal kit and an overhaul kit provide all the parts required for maintenance of the LGS-1 sample pump. See the table below for part numbers. Table 3: LGS-1 Pump Spare Parts Part Number Description 9A-50142150715...
  • Page 21 Section 6: Spare Parts List Page Left Intentionally Blank...
  • Page 22 LGS-1 Liquid and Gas Sample Pump Page Left Intentionally Blank...
  • Page 23 Section 6: Spare Parts List Page Left Intentionally Blank...
  • Page 24: Appendix A: Publisher Notes

    Sensia pursues a policy of continuous improvement, and information given herein may be updated without notice. Further, this information is proprietary to Sensia, and must not be disclosed to any third party except as may be required to operate the equipment supplied in accordance with the purposes for which it was sold...
  • Page 26: Contact Us

    No. 701, S. No. 144&145, Samrat Coraopolis, PA Ashoka Path, YERAWADA, Pune, P.O.BOX 16776, Plot WWA 115, 15108-7766 Maharashtra, India, 411006 DUBAI, U.A.E sensiaglobal.com Add intelligent action to your oil & gas solutions © Sensia LLC 2020. All rights reserved.