Antenna
RF Distribution
1.1 DC In Connection
There are several options for powering the RF Distribution
Module.
1.11
Directly via connection of the supplied 12V DC 1.5 Amp
Plug pack to the 12 VDC Power Input jack F on the unit.
(Use in the event that a modulator is not included in the
system)
1.12
Remotely via a modulator connected to MOD RF IN input
E on the RF Distribution Module. If powering this way
press Remote Power button on the rear of the IR Modulator
to 'ON'. In this setup, DO NOT connect a Plug Pack directly
to the RF Distribution Module.
1.13
Remotely, via a Power Injector (RL-RF900) connected to
the cable terminating on the MOD RF IN input E (see
Instal Manual for Power Injector). For use in the event
that a modulator is not included in the system, but remote
powering of the RF Distribution Module is required.
1.2 DC Out Connection
1.21
Auxiliary Devices such as modem/router can be powered
using 3.5mm to 3.5mm DC lead connected to G .
1.22
NOTE - Output power = 12VDC with max. current 800mA.
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
A
B
J
I
Connect to modem/router
(Max current 800mA)
Radio Frequency Range
resi-linx RF Distribution Module
IR Target
Remote
Control
C
D
Modulator
E
F
12V DC 1.5A
H
G
1.3 Hardware Connection
1.31
If using Modulator for Pay TV/DVD etc, connect RF output
on rear of modulator to MOD RF IN Input E on RF
Distribution Module. This input must be used to remotely
power the RF Distribution Module and allow IR pass
throughout the system.
A modulator connected to CCTV devices (if required)
can be connected to AUX MOD RF IN Input C on RF
Distribution Module.
1.32
Connect the off-air signal (antenna) to the ANT RF IN Input
A on the RF Distribution Module.
Connect up to 8 TV outputs B .
1.33
1.4 Gain Control
1.41
Factory settings are at maximum gain.
1.42
In the event of distortion of modulator signals, reduce Gain
Control J by turning knob anti-clockwise until distortion is
gone.
1.43
NOTE - Gain control reduces the (ANT) antenna signal
Optimal results are attained when ANT signal is within
15db of the modulator signal.
RL-RF380
®
A Antenna RF Input
B TV Inputs
C Auxilliary Mod RF Input
D Protective Earth Connection
E Modulator RF Input
F 12V DC Input
G 12V DC Output
H IR Emitter Port
I FM Trap
J Gain Control
IR Emitter
Vcomm Pty Ltd
ABN: 99 091 281 524
N15275
www.resi-linx.com
Patented

Advertisement

loading

Summary of Contents for Vcomm resi-linx RL-RF380

  • Page 1 1.33 1.13 Remotely, via a Power Injector (RL-RF900) connected to the cable terminating on the MOD RF IN input E (see 1.4 Gain Control Instal Manual for Power Injector). For use in the event that a modulator is not included in the system, but remote 1.41 Factory settings are at maximum gain. powering of the RF Distribution Module is required. 1.42 In the event of distortion of modulator signals, reduce Gain Control J by turning knob anti-clockwise until distortion is 1.2 DC Out Connection gone. 1.43 NOTE - Gain control reduces the (ANT) antenna signal 1.21 Auxiliary Devices such as modem/router can be powered Optimal results are attained when ANT signal is within using 3.5mm to 3.5mm DC lead connected to G . 15db of the modulator signal. 1.22 NOTE - Output power = 12VDC with max. current 800mA. WARRANTY Vcomm Pty Ltd Vcomm Pty Ltd states that the warrant that the customer can rely on is that ABN: 99 091 281 524 provided by the manufacturer. In the event of any warranty claim please contact us and we will forward it to the manufacturer. The manufacturer will N15275 Patented then determine the extent of their liability. This expressly negates, to the extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd. www.resi-linx.com...
  • Page 2 1.63 From the TV output on the IR Target, connect a coaxial fly RF Gain/Loss - ANT +2dB lead to the TV. - Modulator +3dB 1.64 Steps 1.62 & 1.63 can be repeated for up to 8 TV outputs RF Output run distance 60 metres around the premises. NOTE: If an IR Target is not used, Isolation (Modulator inputs to ANT) -80dB an in-line DC block should be used. Power requirement 12V DC feed in by remote Connect IR emitters (RL-IR700/800) to the outputs on the 1.65 power or DC plug pack rear of the IR Modulator. Place the emitter head 10mm to Size (mm) 163(l) x 39(h) x 69(d) either side of the IR receiver of the AV source (depending on environmental conditions). 1.66 If required, connect either Single or Double IR Emitter (RL- IR700/800) to the IR Emitter Port H for local control of AV source. WARRANTY Vcomm Pty Ltd Vcomm Pty Ltd states that the warrant that the customer can rely on is that ABN: 99 091 281 524 provided by the manufacturer. In the event of any warranty claim please contact us and we will forward it to the manufacturer. The manufacturer will Patented N15275 then determine the extent of their liability. This expressly negates, to the extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd. www.resi-linx.com...