Advertisement

Quick Links

SCOPE
This manual contains information concerning the installation, operation and
maintenance of the Vantage 4000. To ensure proper performance of the unit, the
instructions should be thoroughly understood and followed.
Keep the manual in a readily accessible location for future reference.
Changes and additions to the original edition of this manual will be covered by a "CHANGE
NOTICE" supplied with the manual. The change notice will identify the sections in this manual
where the changes have occurred.
Scope............................................................................................................................
General Specifications ...................................................................................................
Installation Procedure .................................................................................................
Enclosure Mounting.......................................................................................................
System Diagram............................................................................................................
Wiring Connections .......................................................................................................
Splice Procedure............................................................................................................
Programming...............................................................................................................
QuikCal Menu Functions ...............................................................................................
Main Flow Screen.....................................................................................................
Review Meter............................................................................................................
Program....................................................................................................................
Measure Units .........................................................................................................
Sensor Install...........................................................................................................
Totalizer .................................................................................................................
4-20 Output .............................................................................................................
Damping.................................................................................................................
Lost Signal..............................................................................................................
Flow Simulation ......................................................................................................
Integrator ................................................................................................................
Setpoints .................................................................................................................
Relays.....................................................................................................................
Daily Sum .................................................................................................................
Data Logger..............................................................................................................
System Setup.............................................................................................................
Vantage 4000
Vantage 4000

Table of Contents

1-1
Section
1
1-1
1-2
2-1
2-1
2-2
2-3
2-5
3-1
3-1
3-2
3-2
3-2
3-2
3-3
3-5
3-6
3-6
3-7
3-7
3-7
3-8
3-8
3-8
3-9
3-9
942000
12/02

Advertisement

Table of Contents
loading

Summary of Contents for Eastech Badger Vantage 4000

  • Page 1: Table Of Contents

    SCOPE This manual contains information concerning the installation, operation and maintenance of the Vantage 4000. To ensure proper performance of the unit, the instructions should be thoroughly understood and followed. Keep the manual in a readily accessible location for future reference.
  • Page 2: General Specifications

    50 feet of Triaxial PVC coated Std (1000 ft maximum) Belden 9222 or equal Electronic IP66/NEMA 4X standard, temperature range: -4° to 158° F (-20° to 70° C) Enclosure Optional with heater, temperatures down to -40° F (-40°C) Vantage 4000...
  • Page 3: Enclosure Mounting

    Hinge Lock and Optional Door Lock There are two plastic gray plugs supplied with the Vantage 4000. These plugs may be used to permanently disable one side of the hinged handles. If an optional door lock was supplied with the unit then one side of the hinge handle should be plugged and the other side will have the key lock used.
  • Page 4: System Diagram

    Note: The key will have to be left in the hinge handle if the door is to remain unlocked. The only way the key can be removed is if the hinge handle is locked. Vantage 4000 Recommended System Diagram NEMA 4X/IP66 Enclosure...
  • Page 5: Wiring Connections

    Wiring Diagram There are three terminal strips provided for all wiring of the Vantage 4000. The AC power terminal is separate from the other two terminal strips. The power terminal strip has three connections for High, Low and Ground for AC voltage only. Refer to the wiring diagram below for all internal wiring connections.
  • Page 6 Place the two pair of clamps over the middle and outer shields and secure them into place. Verify that the clamps are making good contact with the shields and that no wires of the shie lds are extending beyond their own clamp down area. Vantage 4000...
  • Page 7: Splice Procedure

    Pointed tool (customer supplied) Junction box (customer supplied) A cable connection kit may be purchased through Eastech Badger that will include the * items above (Part # 541874). Trim each of the four cables at the junction box to 9 inches in length. Each of the four cables can now be prepared as described in the sequence following: Using a knife, trim two inches of the outer jacket from each cable.
  • Page 8: Quikcal Menu Functions

    Programming of the main display will be explained later FwdT in the manual. To program, recalibrate or change any function in the Vantage 4000, press the “ MENU” key. This will display Status - Okay the Main Menu for all of the functions of the Vantage 4000 QuikCal firmware.
  • Page 9: Main Flow Screen

    The dimesion units will allow the user to select the engineering measuring units desired to be selected. Available dimesional units are: 01) Inches, 02) Feet, 03) Meters, 04) Centimeters and 05) Millimeters. After pressing the selected dimension units number desired the program will automatically take you back to the Program/Cal. Screen. Vantage 4000...
  • Page 10: Sensor Install

    16) ST30-640 is the old style high temperature strap on sensor used with the older Model 4500 and is 640KHZ operating frequency. 17) SO52-1280 is the old style strap on sensor used with the older Model 4500 on thin wall or copper/brass pipes and is 1280KHZ operating frequency. Vantage 4000...
  • Page 11 Selections are: 01) None, 02) Epoxy, 03) Glass, 04) Bitumastic, 05) Rubber, 06) Mortar, and 07) Other. After pressing the selected pipe liner number desired the program will automatically take you to the Liner Thickness screen. If 01) None was selected the next screen will be the Fluid Type screen. Vantage 4000...
  • Page 12: Totalizer

    Fluid Viscosity in Centipoise (Cp) Specific gravity of fluid If the sonic velocity of the fluid is not known you may call Eastech Badger at 1 -800-226-3569. We have a library of various fluids and the associated sonic velocities. After entering the fluid parameters the next screen will be the Sensor Shot Type screen.
  • Page 13: Output

    Press the enter key to return to the main menu. >05) Damping: >05) Damping This option will allow the user to select the damping or response time of the flow meter. Press the 05 on the keypad. Vantage 4000...
  • Page 14: Lost Signal

    The cursor will appear on the most significant digit. Use the number keys to enter the totalized flow value you want to have for a contact output. Press the ENTER key to return to the main program screen. Vantage 4000...
  • Page 15: Setpoints

    Daily Sum: View the Average, Minimum and Maximum flows and the time of the event for the last eight days of flow. Press the ENTER key to return to the main program menu. This concludes the Daily Sum selections. Vantage 4000...
  • Page 16: Data Logger

    Press the 5 key to clear all stored data. This completes the Data Logger selections. >05) System Setup >05) System Setup The system setup option will allow the user to set up the Vantage 4000 for the following options: Vantage 4000...
  • Page 17 >05) System Setup (Continued) 01) Language: This will allow the user to select the language displayed in the Vantage 4000. The options are: 01) English, 02) German, 03) Spanish. 02) Display: Choosing this feature allows the user to select the contrast of the display from 01) Highest to 08) Lowest.
  • Page 18 A claim for equipment damaged in transit is the sole responsibility of the customer. NUCLEAR DISCLAIMER Equipment sold by Eastech Badger is not intended for use in connection with any nuclear facility or activity unless covered by a specific quotation where the conditions of such usage will be detailed. If...

Table of Contents