Advertisement

Avant Wellness Systems
LZ30 & LZ30-X Therapy Laser
User Manual
Ver. 1.05 (02/2015)
P/N 2302324
© 2015 Avant Wellness Systems, LLC. All Rights Reserved.
Avant Wellness and LZ30 are either registered trademarks or trademarks of Avant Wellness Systems in the United States and/or
other countries.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LZ30 and is the answer not in the manual?

Questions and answers

Teresa Lassen
May 1, 2025

[1] When it is time to have a calibration done, where would I send it? I am concerned about mailing it because fedex, ups and usps are no longer very trustworthy. I am in the houston area. Is there anywhere near that I could drop it off? [2] is there any reason to not treat an area daily? I cannot find this addressed anywhere.

Guilherme Poiani
February 7, 2025

Como criar e salvar uma configuração diferente das usuais para utilizar em uma pesquisa? Como é possível ter acesso ao passo a passo para fazer isso?

Subscribe to Our Youtube Channel

Summary of Contents for Avant Wellness Systems LZ30

  • Page 1 LZ30 & LZ30-X Therapy Laser User Manual Ver. 1.05 (02/2015) P/N 2302324 © 2015 Avant Wellness Systems, LLC. All Rights Reserved. Avant Wellness and LZ30 are either registered trademarks or trademarks of Avant Wellness Systems in the United States and/or other countries.
  • Page 2: Table Of Contents

    LZ30 User Manual CONTENTS CONTENTS SECTION 1: INTRODUCTION ................4 SECTION 2: EQUIPMENT LIST ................5 ................... 5 MPACT ARRY ......................6 ANDPIECE ..................... 6 AFETY LASS ......................6 HARGER ..................7 ASER ARNING SECTION 3: SAFETY ................... 8 ...................... 8 RECAUTIONS .....................
  • Page 3 SECTION 12: MAINTENANCE ................32 ..................32 NNUAL AINTENANCE .................... 32 AILY AINTENANCE .............. 32 ONTAMINATION ONTROL ROCEDURES ....................32 RANSPORTATION ......................32 TORAGE ....................... 33 ALIBRATION SECTION 13: LZ30 LIMITED WARRANTY ............34 Ver. 1.05 (02/2015) P/N 2302324 Page 3...
  • Page 4: Section 1: Introduction

    The LZ30 delivers infrared laser radiation in the visible and invisible spectrum. The LZ30 laser is indicated for use by a licensed healthcare professional, or by order of a licensed healthcare professional. The use of this device requires proper clinical and technical training.
  • Page 5: Section 2: Equipment List

    LZ30 User Manual Section 2: EQUIPMENT LIST Section 2: EQUIPMENT LIST The LZ30 kit consists of the following items of equipment: High Impact Carry Case Ver. 1.05 (02/2015) P/N 2302324 Page 5...
  • Page 6: Handpiece

    LZ30 User Manual Section 2: EQUIPMENT LIST Handpiece Safety Glass Two styles of glasses are provided, one that can be worn over regular glasses. Charger Ver. 1.05 (02/2015) P/N 2302324 Page 6...
  • Page 7: Laser Warning Sign

    LZ30 User Manual Section 2: EQUIPMENT LIST Laser Warning Sign Ver. 1.05 (02/2015) P/N 2302324 Page 7...
  • Page 8: Section 3: Safety

    Laser Safety LZ30 is a Class 3B laser device. The FDA has determined that a Class 3B laser is hazardous if the eye is exposed directly, but diffuse reflections such as those from paper or other matte surfaces are not harmful.
  • Page 9: Safety Features

    However, the possibility of electromagnetic or other interference may still exist. DANGER: There are no user serviceable parts inside the LZ30. Do not attempt to open the unit housing at any time. Contact Avant if you believe that your device is not functioning correctly.
  • Page 10 Avant to be reset Automatic Power Control Each of the laser diodes in the LZ30 has an integrated chip that measures optical power output. This provides very accurate regulation of power output and eliminates variations in output power that would otherwise occur due to age, wear and temperature.
  • Page 11: Safety Classification

    LZ30 User Manual Section 3: SAFETY Diode Measures the temperature of the Switch off all diodes Temperature laser diodes to ensure that they Terminate treatment program remain within specified limits. Report error to user. Wait until diodes have cooled. Battery...
  • Page 12: Section 4: Clinical Applications

    Pain affected sites, muscles and/or joints, have to be exposed to an adequate level of therapeutic energy for effective therapeutic effects. The LZ30 may be applied directly to the skin. Most patients will feel a very mild warmth. In rare cases of discomfort, increase the distance between the device and the skin and/or reduce the power.
  • Page 13: Universal Aperture At 30 Mm Spot Size (Against The Skin)

    (above). Universal Aperture The Universal Aperture is installed on the LZ30 when you receive it. This aperture is designed for a wide beam divergence and hence can be applied directly against the patient. This is the recommended use, since it also increases patient and operator safety by eliminating stray radiation.
  • Page 14: Section 5: Device Overview

    ... Button. A multifunction button used to navigate the menu, to start and stop treatment and to power the device on and off..USB Port. Used to charge LZ30 and also to connect to a computer for configuration and updating system software.
  • Page 15: Display Layout

    LZ30 User Manual Section 5: DEVICE OVERVIEW Advanced mode provides unlimited access to all device features. Each mode of operation is accessible based on the password that is entered at power up. The device has two distinct passwords that are used to start the device in either mode.
  • Page 16: Section 6: Operation

    This folder contains pre-defined treatment settings. Presets contain all the laser parameters used for a particular condition. The LZ30 is preconfigured with a basic set of treatments for temporary relief of minor muscle and joint pain and stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation and temporary relaxation of muscles.
  • Page 17 All operations are accessed via the graphic menu. The menu is navigated using the button that recognizes movement in the directions indicated above. Below is a summary of each the button gestures used to control the LZ30, and how they are performed:...
  • Page 18 LZ30 User Manual Section 7: CONTINUOUS USE AND OVERHEATING CLICK-FRONT Press and release the front edge of the button frame (closest to the display). CLICK- BACK Press and release the back edge of the button frame (furthest from the display).
  • Page 19 LZ30 User Manual Section 7: CONTINUOUS USE AND OVERHEATING When.. doing this results in.. The LZ30 is off HOLD-CENTER Powers on the LZ30. Entering the CLICK-FRONT/BACK/ Passwords are recorded as a sequence of button password LEFT/RIGHT operations. BACK enters a “”, FRONT enters “”, LEFT enters a “”, RIGHT enters “”.
  • Page 20: Menu Navigation

    LZ30 User Manual Section 7: CONTINUOUS USE AND OVERHEATING Menu Navigation Button Menu Item Scrollbar Figure 4: Main Window Components (navigation) During menu navigation, the Main Window is organized into three areas as shown above. The Button area indicates which of the button directions are active. The narrow ...
  • Page 21 Unpin from Fav: Unpin the selected item from Favorites. Offered if the item is already pinned to Favorites. Saved Location LZ30 will power up with the menu in the same position as when it was powered off. Favorites Display Format Shows the location of the item in the menu.
  • Page 22: Section 7: Continuous Use And Overheating

    The LZ30 will become warm during operation. The temperature is carefully monitored and if the LZ30 exceeds its safe operating temperature, it will automatically switch off the lasers in order to cool down. The amount of time that it takes to reach the maximum temperature and how long it takes to cool down depend upon ambient temperature and how the laser is being used.
  • Page 23 LZ30 User Manual Section 7: CONTINUOUS USE AND OVERHEATING The red lasers are more sensitive to elevated temperatures than the infrared lasers. Therefore, when using a preset that uses the red lasers immediately after using the infrared lasers, the device might need to cool down further. Typically this takes less than a minute.
  • Page 24: Section 8: Battery Management And Charging

    Section 8: BATTERY MANAGEMENT AND CHARGING The LZ30 has an internal lithium ion battery that is charged via the USB port. A wall adapter is provided with LZ30. While this charging system makes it possible to use any micro-USB charger, the specified electrical safety rating of the LZ30 equipment applies to the supplied charger only.
  • Page 25: Section 9: Device Updates

    (memory stick). When the LZ30 is plugged in, it will display a message “Click to connect”. If you CLICK the button, then the LZ30 will terminate the active preset and make its internal drive visible to the host computer.
  • Page 26: Updating System Software

    Avant to reset it. Presets LZ30 can hold up to many preset configurations. Each preset has its own unique set of configurable parameters, including power pulsing, dose amount, treatment timers and help information.
  • Page 27: Section 10: Specifications

    LZ30 User Manual Section 10: SPECIFICATIONS Section 10: SPECIFICATIONS General Dimensions (W x H x L) .... 1.25” x 1.25” x 4.5” (30mm X 30mm X 120mm)  Weight ........4oz (125g)  Electrical USB Wall Charger Operating Voltage ..... 100..240VAC @ 0.5A ...
  • Page 28 1% - 99% Duty Cycle  Frequency ......... 0.1Hz - 50kHz 0.1 - 2kHz NOHD (cap removed) ....6’ (22’ for LZ30 -X)  NOHD (cap installed) ....14” (29’ for LZ30 -X)  DANGER: Viewing the beam directly or via a reflective surface within the NOHD...
  • Page 29: Section 11: Contraindications, Warnings And Precautions

    WARNINGS AND PRECAUTIONS Contraindications All clinical procedures performed with the LZ30 must be subjected to the same clinical judgment and care as with traditional techniques. Patient risk must always be considered and fully understood before clinical treatment. The clinician must completely understand the patient’s medical history prior to treatment.
  • Page 30 1 of 6 different types of skin. The therapeutic power level for the LZ30 is determined based on the patient skin type and tolerance to heat at the location of treatment. Treatment site assessment is also required to determine treatment conditions and laser power settings and dose applicable to the patient.
  • Page 31 LZ30 User Manual Section 11: CONTRAINDICATIONS, WARNINGS AND PRECAUTIONS Training Training by an Avant representative is required. Only licensed professionals who have read and understood this User Manual may use this device. Avant assumes no responsibility for parameters, techniques, methods or results. Physicians must use their own clinical judgment and professionalism in determining all aspects of treatment, technique, proper power settings, interval, duration, etc.
  • Page 32: Section 12: Maintenance

    Representative. Storage The LZ30 should be stored in a cool dry place when not in use. Store the unit in a temperature range from 0°C - 40°C with a relative humidity of 10%-70%. Place the LZ30 in its transport case when not in use for extended periods of time. Store the system in a place where it will not be accidentally bumped or banged.
  • Page 33: Calibration

    LZ30 User Manual Section 12: MAINTENANCE Calibration Calibration procedure is recommended to be performed every 12 months in order to maintain the required accuracy of output power. Annual calibrations are performed at Avant. Contact Avant or your authorized Representative to schedule calibration.
  • Page 34: Section 13: Lz30 Limited Warranty

    (c) All accessories used with the LZ30 must be manufactured by or certified in writing by Seller. Use of non-authorized accessories will void the warranty, all service contracts and all liability to Seller.
  • Page 35 LZ30 User Manual Section 13: LZ30 LIMITED WARRANTY ANY INCIDENTAL OR CONSEQUENTIAL INDIRECT OR SPECIAL DAMAGES OF ANY KINDS, INCLUDING BUT NOT LIMITED TO, DAMAGES FOR LOSS OF REVENUE, LOSS OF BUSINESS OR BUSINESS OPPORTUNITIY, OR OTHER SIMILAR FINANCIAL LOSS ARISING OUT OF OR IN CONJUNCTION WITH THE PERFORMANCE, USE OF OR INTERRUPTED USE OF SELLER’S PRODUCTS,...

This manual is also suitable for:

Lz30-x

Table of Contents