Techno GR F3S-TGR-SB4-K C Series User Manual

Techno GR F3S-TGR-SB4-K C Series User Manual

Safety light curtain

Advertisement

Quick Links

F3S-TGR-SBx-KxC series
F3S-TGR-SB4 – KxC
Type 4 Safety Light Curtain
F3S-TGR-SB2 – KxC
Type 2 Safety Light Curtain
USER'S MANUAL
User's manual
F3S-TGR-SBx-KxC series
This instruction Manual describes the F3S-TGR-SBx-KxC Safety Light Curtain
(SLC).
General Safety Requirements
Always heed the following points when using the F3S-TGR-SBx-KxC:
Regulations and Standards
1. The F3S-TGR-SBx-KxC safety light curtains are electro-sensitive
2. The F3S-TGR-SBx-KxC complies with the following regulations and
3. The F3S-TGR-SBx-KxC received the following approvals from notified
1
INTRODUCTION
Read this manual thoroughly to understand and make good use of the
descriptions before installing and operating the product.
A qualified person should conduct a risk assessment on the machine, and
determine the suitability of this product before installation.
Keep this Manual at the place where the operator can refer to it whenever
necessary.
Do not open the housing or make any unauthorised modifications.
The power supply must be disconnected before proceeding with any
external intervention.
Regulations and Standards
protective equipment (ESPE) in accordance with European Union (EU)
Machinery Directive Annex IV, B, Safety Components and Item 1.
standards:
(1) EU regulations
Machinery Directive:
EMC Directive:
(2) European standards:
body TÜV Product Service:
EC Type-Examination in accordance with the EU Machinery Directive
TYPE 2 and 4 ESPE (EN61496-1),
TYPE 2 and 4 AOPD (prEN61496-2)
Certificate of a Notified Body for EMC
User's manual
Directive 98/37/EC
Directive 89/336/EEC
EN61496-1, prEN61496-2
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F3S-TGR-SB4-K C Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Techno GR F3S-TGR-SB4-K C Series

  • Page 1 F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual INTRODUCTION This instruction Manual describes the F3S-TGR-SBx-KxC Safety Light Curtain (SLC). General Safety Requirements Always heed the following points when using the F3S-TGR-SBx-KxC: • Read this manual thoroughly to understand and make good use of the descriptions before installing and operating the product.
  • Page 2 NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE In no event shall responsibility of TECHNO GR for any act exceed the individual price HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE TECHNO GR of the product on which liability is asserted.
  • Page 3: Table Of Contents

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual INDEX DEFINITION OF SYMBOLS section page Information in this manual that is of particular importance can be identified as OPERATION ..................7 follows; PRECAUTIONS AND CRITERIA FOR INSTALLATION ....8 CALCULATION OF THE MINIMUM DISTANCE FOR INSTALLATION ....8 WARNING indicates a potentially hazardous situation, which, if not avoided, will result in minor or moderate injury, or may result in serious REFLECTING SURFACES...................
  • Page 4: Operation

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual OPERATION PRECAUTIONS AND CRITERIA FOR INSTALLATION The Safety Light Curtain (SLC) is made up of one active side with The area where the SLC is to be installed must be compatible with the SLC transmitter and receiver optical elements called the transceiver and one ‘s technical specifications.
  • Page 5: Reflecting Surfaces

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual REFLECTING SURFACES F3S-TGR-SBx-KxC series do not use in a horizontal position Be sure to install the SLC to minimize the effect of reflection from nearby surfaces. Serious injuries can result if these effects are not taken into consideration.
  • Page 6 F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual If several SLCs are used, care must be taken that each SLC does not Insert a non-transparent wall if it is not possible to connect the SLC as interfere with the ones nearby; please install as follows: shown previously.
  • Page 7: Mechanical Assembly

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual MECHANICAL ASSEMBLY CONNECTIONS Use the appropriate brackets provided to complete the mechanical REFERENCES FOR CABLES: assembly. The test connection must always be executed with a N.C. button or The securing brackets nuts slide in the container’s grooves so the connected to an automatic device, such as a PLC.
  • Page 8: Notes On Connections

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual ALIGNMENT PROCEDURE NOTES ON CONNECTIONS After completing correct mechanical assembly and connections, as • The transformer needed to power the system must comply with described in the previous sections, the SLC should be aligned as follows: standard EN 60742 (dual isolation), or with equivalent isolation, e.g.
  • Page 9: Operating Procedures

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual OPERATING PROCEDURES 7 MUTING AND OVERRIDE FUNCTIONS SETTING THE INTERNAL DIP-SWITCHES GENERAL INFORMATION • Disconnect the SLC’s power supply and remove the connector side The muting and override functions enable the SLC to be bypassed for of the transceiver, so that you can reach the two banks four-way dip-switches located there.
  • Page 10: Partial Muting Configuration

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual CRITERIA FOR INSTALLATION PARTIAL MUTING CONFIGURATION. Take adequate care when installing the muting sensors to prevent undesired requests for muting: This feature is available only on the F3S-TGR-SBx-K3C and F3S-TGR-SBx- K4C models. 1.
  • Page 11 F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual The following drawings show several examples of configurations with the Application with four sensors and single direction for material use of the muting function: exit: Application with four sensors – ‘Bi directional muting’ +24Vdc Electrical connection of muting input +24Vdc...
  • Page 12 F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual Application with two sensors and single direction for material exit: Where: D: minimum dimension of package that can cross the SLC. This muting activation sequence is only available for SLCs with postfix “–MTL” at the ordering code. D1: distance between muting actuator B and SLC.
  • Page 13: Timing Constraints (Muting Function)

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual • The TEST/RESTART button must be located so that the operator can see the protected area when restarting, testing or overriding. Timing constraints (for SLCs with postfix “–MTL” at the ordering • code) The external illuminated indicator for muting override enabled must be located so that it can be seen from all sides of operation.
  • Page 14: Override

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual OVERRIDE LED DIAGNOSTICS This function makes it possible to override or bypass the system. It is used to start up the machine after the material has interrupted one LED’s Description or more of the SLC beams and to free the protected area from any The operator is able to recognise the operating status of the SLC by material that is present in front of the SLC, means of five LED located on the transceiver.
  • Page 15: Final Checks

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual 11 GENERAL INFORMATION AND USEFUL DATA Faulty conditions Everyone MUST be aware of issues regarding safety. LED signal Pattern Description Safety devices are only useful if they are installed correctly according to the recommendations set down by regulations.
  • Page 16: Technical Specifications

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual ITEM SPECIFICATION 12 TECHNICAL SPECIFICATIONS Materials Housing Powder-coated aluminum, ITEM SPECIFICATION Front panel Polycarbonate Sealing gasket EPDM (synthesis rubber) Rated operating distance 0,5m … 6,0m K2C model Connector parts Metal: Galvanized brass 0,5m …...
  • Page 17: Dimensions

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual ITEM SPECIFICATION 13 DIMENSIONS Output circuit protection PNP short circuit protected All dimensions are shown in millimetres Output current 250 mA each OSSD Mounting bracket Max. Capacitive load 200nF (pure capacitive load) Output voltage drop <...
  • Page 18: Note

    F3S-TGR-SBx-KxC series User’s manual F3S-TGR-SBx-KxC series User’s manual 14 NOTE MODEL F3S-TGR-SBx-K2C-500 F3S-TGR-SBx-K3C-800 F3S-TGR-SBx-K4C-900 1058...