Adani Solar ASP-7-AAA Installation Manual

Adani Solar ASP-7-AAA Installation Manual

Pv module

Advertisement

Quick Links

MUNDRA SOLAR PV LIMITED
Adani House,
Near Mithakhali Circle,
Navrangpura, Ahmedabad – 380009,
Gujarat, India
Tel : +91 79 2656 5555 Fax: +91 79 2555 55.
PV MODULE INSTALLATION
MANUAL IEC & UL VERSION
Applies to the below PV Module
A S P - 7 - A A A
A S P - 6 - A A A
A S P - 6 - B - A A A
A S P - 6 - A B - A A A
ASM-7-PERC-AAA
A S M - 6 - P E R C - A A A
ASM-6-B-PERC-AAA
ASM-6-AB-PERC-AAA
A S P - 1 4 - A A A
A S M-1 4 -PE R C-A A A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASP-7-AAA and is the answer not in the manual?

Questions and answers

Summary of Contents for Adani Solar ASP-7-AAA

  • Page 1 PV MODULE INSTALLATION MANUAL IEC & UL VERSION Applies to the below PV Module MUNDRA SOLAR PV LIMITED A S P - 7 - A A A A S M - 6 - P E R C - A A A Adani House, Near Mithakhali Circle, A S P - 6 - A A A...
  • Page 2: Table Of Contents

    C O N T E N T 1. DISCLAIMER OF LIABILITY 2. SAFETY MEASURES 2.1 Fire Safety 3. PV MODULE UNPACKING AND STORAGE Module Identification 4. ENVIRONMENTAL CONSIDERATIONS Climate Conditions 5. SITE SELECTION 6. MOUNTING INSTRUCTION 6.1 Mounting Methods A. Bolt Type Fixing B.
  • Page 3: Disclaimer Of Liability

    2.1 Fire Safety installation affect is referred as Adani / Adani Solar in under direct sunlight, it is advised to use reduce its performance and building fire safety; improper the Installation Manual as MSPVL is installation tools and for precaution, wear hand life cycle.
  • Page 4: Pv Module Unpacking And Storage

    In installations not under the requirements of the NEC, the values capacity of PV module that is 2400 Pa for All Adani Solar modules are tested for IEC 61215, IEC of ISC and VOC marked on this module should be multiplied by a vertical side as shown in figure...
  • Page 5: Site Selection

    Drainage holes should be kept open and no blockage is allowed in the drainage • Sufficient row to row gap has to be hole. chosen and PV modules should be Mechanical Drawings of PV Module “ASM-7-PERC-AAA & ASP-7-AAA”. spaced between rows appropriately such that no shadows...
  • Page 6: Clamp Type Fixing

    Fig 3: PV Modules Installed with screw fitting method Fig 4: PV Modules Installed with Fringe Clamping Method B. Clamp Type Fixing ADANI Solar has done number of tests on clamps and on the basis of that test results, it is Middle Modules Installation recommended to use clamps with EPDM or with insulating type washer only.
  • Page 7 Mounting Methods At 2400 Pa load condition At 5400 Pa load condition Mounting Hole Mounting Hole Bolt type Fixing Use Four Mounting Hole Use Eight Mounting Hole Long Side Clamping • Figures to represent mounting methods and applies to all 144, 72, &...
  • Page 8 Dimensions depending on Module type in (mm) Typical specification of ASP-7-AAA series modules ASP-7-AAA; ASP-6-AAA ; ASP-14-AAA Temp coefficient of Current 0.069 %/°C ASM-7-PERC- ASM-6-PERC- ASM-14-PERC- AAA; ASM-6-B- Model Name PERC- AAA ; Temp coefficient for voltage -0.31 %/°C ASM-6-AB- PERC-AAA Temp coefficient of Power...
  • Page 9: Pv Module Grounding

    For grounding hole location and its size earth ground electrode. please refer to the product catalogue. • ADANI solar modules can be installed by • Adani recommends following grounding using any third party listed grounding Fig: Grounding assembly of PV module...
  • Page 10 “A module with exposed conductive parts is considered to be in compliance with UL 1703 only when it is electrically grounded in accordance with the instructions presented below and the requirements of the National Electrical Code. Procedure 1:- Grounding by bolts: 2058729-1 Procedure 3: ERICO grounding bolt EL6CS14-6 1) Wire bolt and slot 2) Mounting wash hex nut 3) Aluminium frame 4) 4 to 16mm2 cable 5) HEX nut...
  • Page 11 Storage solutions. connecting modules in series , positive connector of one module is connected to • ADANI Solar modules contains copper the negative terminal of another module. cables with 4mm2 cross-sectional area During series connections, please ensure with voltage rating 1000V/1500V (IEC&UL)
  • Page 12: Connectors

    6.5 Bypass Diodes 6.4 Connectors • Protect unplugged connectors against moisture, dust and any • Bypass diodes divert current from the cell strings in the environmental pollution. Only clean and dry plugged connectors event of partial shading. fulfil their ingress protection (IP) class. Ensure that connector •...
  • Page 13: Electrical & Mechanical Parameters

    7. ELECTRICAL & MECHANICAL PARAMETERS Type name or ASP-7-AAA ASP-6-AAA ASM-7-PERC- model number ASP-6-B-AAA ASP-6-AB-AAA Rated maximum 340-385 315-350 265-270 power range Module Multicrystalline Multicrystalline Monocrystalline technology Number of cells Rated short 8.10-9.60 8.10-9.50 8.7-10.37 circuit current range [A] Rated open 43.3-46.7...
  • Page 14: Electrical Configuration

    Crystalline Silicon • There is always a risk of Lightening to PV Power plants and PV modules and Adani Solar are met, this is converted series modules requests the EPC Installer and the customer to analyse the risk of lightening as per IEC into AC power accordingly.
  • Page 15: Pv Module Maintenance And Care

    Check for any shading on PV module, area of module on which light is falling should not be ay death also. ADANI solar is not responsible for any type of accident occurring in Power pl shaded by any trees, objects and leaves. All these obstructing objects should be removed ant using ADANI panels.