Chlorine Tech Services CTS-IB-PPE-01 Instruction Booklet

Self-contained breathing apparatus

Advertisement

Quick Links

INSTRUCTION BOOKLET
(CTS-IB-PPE-01)
SELF-CONTAINED BREATHING
APPARATUS (SCBA)

Advertisement

Table of Contents
loading

Summary of Contents for Chlorine Tech Services CTS-IB-PPE-01

  • Page 1 INSTRUCTION BOOKLET (CTS-IB-PPE-01) SELF-CONTAINED BREATHING APPARATUS (SCBA)
  • Page 2: Table Of Contents

    7. TECHNICAL SPECIFICATIONS ................14 8. ACKNOWLEDGEMENTS..................14 Read and understand the respective instructions for use for each Device before using the equipment. ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e...
  • Page 3: Safety Regulations

    1.2. Liability Information Chlorine Tech Services accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator. Product liability claims,...
  • Page 4: Workings Of The Scba

    In case that the facemask is dislodged in a toxic atmosphere, the wearer should hold his breath and position the mask correctly. Any inlet of such toxic air can be highly dangerous. ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e...
  • Page 5: Air Consumption

    Nervousness and excitement can cause an increased demand of oxygen and a proportionate increase of respiration rate. 2.4. Basic Unit – Backplate, pneumatic system without second connector Fig. 2 ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e...
  • Page 6: Pressure Reducer

    It is no allowed to disassemble the reducer by the user. Don’t damage the seal surface when replacing the seal O ring on the high-pressure connection. ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e...
  • Page 7: The Demand Valve

    The explosion pressure for medium pressure hose is not less than four times of the reducer output pressure. Connection of the medium pressure hose with the demand ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15...
  • Page 8: High Pressure Hose

    Check gasket on pressure reducer for proper condition. Open cylinder buckle on the cylinder strap eliminating any tension and extend the strap. ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e...
  • Page 9: Donning (Putting On) The Scba

    • Place the SCBA over one shoulder • Then the other harness over the remaining shoulder • SCBA must rest in middle of back ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e...
  • Page 10 • Fully open the cylinder valve (slowly) to pressurise the system • Check the pressure gauge (should read between 250/300 bar) ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e | 10...
  • Page 11 • Check that the pressure on the pressure gauge reads full ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e | 11...
  • Page 12: Doffing (Taking Off) The Scba

    • Check that Pressure Gauge is on Zero pressure • Press Red Button to reset system Step 3 • Extend waistbelt straps and open waist belt buckle ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e | 12...
  • Page 13: Maintenance Instructions

    Medium & Appearance High- pressure Sealing properly parts Cleaning Pressure gauge Breathing Complete set cleaning device Function test, leak test Completeness test ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e | 13...
  • Page 14: Cleaning

    Self-contained Open-circuit Compressed Air 8.1. MSA 2015 - Operating Manual Breathing Apparatus INTERSPIRO – User Manual 8.2. Dräger – Donning and Start-up Procedure 8.3. ©Chlorine Tech Services (Pty) Ltd – CIPC Reg # 2018/101848/07 Rev # 01/2020/10/15 P a g e | 14...