Another feature of this instrument is its output ON/OFF key. a. For model PS-303DU/305DU, it is only the key to cut off or resume the output as other similar instrument. b. For model PS-2303/2305, it is not only the key to cut off or resume the output, but also be endowed with a new function which its kindred has not.
Between chassis and AC cord:≥300MΩ/500VDC Operating environment 0℃~40℃, ≤80%RH Storage environment -10℃~70℃, ≤70%RH Power source AC110V/220V±10%, 50/60Hz Accessories Power cord x1, Operation manual x1 4. PANEL CONTROLS AND INDICATORS 4-1. Panel Illustration a. PS-303DU/305DU Front panel - 3 -...
Page 6
Fig.4-2 b. PS-2303/2305 Front panel Fig.4-2 c. PS-3010DU/6005DU Front panel - 4 -...
Page 7
Fig.4-3 d. PS-303DU/305DU Rear panel Fig.4-4 e. PS-2303/2305 Rear panel - 5 -...
4-2. Front Panel Control Power switch : ON/OFF the power input. V LED display : Indicates the MASTER output voltage. V LED display : Indicates the SLAVE output voltage. A LED display : Indicates the MASTER output current. A LED display : Indicates the SLAVE output current.
5. OPERATION INSTRUCTIONS 5-1. Precaution 1) AC input AC input must be within the range of line voltage ±10%, 50/60Hz. WARNING. To avoid electrical shock, the power cord protective grounding conductor must be connected to ground. 2) Installation Avoid using the supply in a place where the ambient temperature exceeds 40℃. Allow enough space around the power supply for ventilation.
to the load change. The intersection of constant voltage and constant current modes is called the crossover point. Fig.5-1 shows the relationship between this crossover point and the load. For example, if the load is such that the power supply is operating in the constant voltage mode, a regulated output voltage is provided.
INDEPENDENT operating mode. Adjust "Voltage" control and "Current" control to the desired output voltage and current. Turn off the power supply and the equipment to be powered during hook-up. Connect the positive polarity of the device being powered to the red (+) terminal of the power supply. Connect the negative polarity of the device being powered to the black (-) terminal of the power supply.
If "single supply" operation is desired, this allows the power supply to be used as twice the voltage and rating current simply by using the negative (black) terminal of the SLAVE supply and the positive (red) terminal of the MASTER supply, the configuration as shown in Fig.5-3. Fig.5-3 Single Supply If the chassis or common of the equipment being powered is separate from both positive and negative polarity power inputs.
Connect the negative polarity of the device being powered to the black (-) terminal of the MASTER power supply. The configuration is as shown in Fig.5-5. Fig.5-5 Parallel Tracking Operation 5-4-4. Fixed 5V Power Supply Operation The fixed 5V supply provides a 5V DC output with a 3 amp current capacity. The supply is ideal for use with TTL circuits.
Fuse rating: Model 220VAC rated input 110VAC rated input PS-303DU TSD3.15A TSD6.3A PS-2303 TSD3.15A TSD6.3A PS-305DU TSD6.3A TSD10A PS-2305 TSD6.3A TSD10A PS-3010DU TSD10A TSD10A PS-6005DU TSD10A TSD10A 6-2. Line Voltage Conversion The primary winding of the power transformer is tapped to permit operation from 110 or 220Vac ±10%, 50/60Hz line voltage.