Download Print this page

Advertisement

Quick Links

Manual of SoundBite Hearing System G3/G3S
Table of Content
1 Product Description
6 Symbol Table
1. Product Description
The SoundBite Hearing System is a non-surgical and removable bone conduction
hearing device designed to transmit sound through the teeth.
1.1 Intended use of product:
The SoundBite Hearing System is intended for patients 18 years and older with the
following indications:
- Patients with moderately severe, severe, or profound sensorineural hearing loss in
one ear and normal hearing in the other ear (i.e. single sided deafness or "SSD").
Normal hearing is defined as a pure tone average (PTA) air-conduction (AC)
hearing threshold (measured at 0.5, 1, 2, and 4 kHz) of better than or equal to 25
dB HL.
- Patients with
bone-conduction hearing threshold (measured at 0.5, 1, 2, and 4 kHz) is better
than or equal to 25 dB HL.
Additionally, use of SoundBite is intended for patients with:
- At least two contiguous molar or premolar teeth with no untreated tooth decay.
Patients with tooth decay present are to first have restorations before being fitted
for SoundBite;
- Healthy attachment to those teeth with tooth pockets limited to no more than 5mm;
- No mobile teeth;
- Bone loss no greater than a 34% average on the mesial and distal sides of the
tooth as measured on X-ray on the teeth on which the device will be worn.
conductive
hearing
loss
where
the pure
tone average
1 / 20

Advertisement

loading
Need help?

Need help?

Do you have a question about the G3 and is the answer not in the manual?

Questions and answers

Summary of Contents for SoundBite G3

  • Page 1: Table Of Contents

    1.1 Intended use of product: The SoundBite Hearing System is intended for patients 18 years and older with the following indications: - Patients with moderately severe, severe, or profound sensorineural hearing loss in one ear and normal hearing in the other ear (i.e.
  • Page 2 1.2 Contraindications: - The SoundBite Hearing System and all portions of it are contraindicated for use in an MRI Environment and should be removed prior to MRI exposure. - The SoundBite Hearing System is not to be used in patients with known hypersensitivity to any of the components including allergies to polymers.
  • Page 3: Operating Instructions

    Power adapter Connecting line Charging plug Warning: Use only the system Charger and power adapter provided. Other power adapters may look similar but may cause damage to your SoundBite device 2. Operation instructions 2.1 Charging 2.1.1 Use of charging system V1.0 Connect the power adapter, connecting wire and charging dock, and switch on the power supply.
  • Page 4 within 5 hours. • If the light is not on, make sure that the device is fully seated in the charging dock. 2.1.2 Use charging system V2.0 (pocket charger) Connect the power adapter, connecting wire and pocket charger, and switch on the power supply. White LED (As shown in the right), the power indicator on the left side lights on...
  • Page 5 General Warnings and Precautions section of this manual. 2.7 Signal interference The SoundBite Hearing System contains a wireless radio link that allows the BTE unit to transmit audio picked up from the impaired ear and transmit it to the ITM device.
  • Page 6: Cleaning And Daily Care

    Please depose in accordance with the local regulations. 3. Cleaning and Daily Care Make sure that your SoundBite Hearing System is properly maintained on a daily basis. 3.1 Cleaning your ITM Device ...
  • Page 7 3.3 Cleaning your Charger Wipe the exterior Charger surfaces with a damp cloth as necessary • Remove the ITM charging dock tray (ITM tray) by pinching the finger rests and • lifting up as shown Clean the ITM tray daily with antibacterial denture cleaner •...
  • Page 8: Troubleshooting

    3. The SoundBite Hearing System battery life is dependent on the sound environment. Reducing time spent in noisy environments can slightly extend battery life.
  • Page 9: Warnings And Cautions

    4. Warnings and Cautions 4.1 Warnings 1 The SoundBite Hearing System and all portions of it are contraindicated for use in an MRI Environment and should be removed prior to an MRI exam or MRI Exposure. Keep the SoundBite Hearing System components away from strong magnetic fields.
  • Page 10 10If ITM is bitten by force inadvertently, please stop using it and contact a hearing health expert. 11 Only the components of the matching charging system (power adapter, charging line, charging dock or pocket charger) can be used. Even other power adapters look similar, but may cause damage to the product.
  • Page 11 13 The multiple systems in distance less than 30cm may interfere with each other. 14 Some devices, including computers, burglary protection systems and mobile phones, may interfere with the SoundBite Hearing System even if they meet the radiation requirements of the International Special Committee on Radio Interference (CISPR).
  • Page 12 5. Symbolic information and explanation Manufacturer Consult the instructions Important information on Attention! Consult the operation and product attached documents safety Serial number Batch code Non-ionizing radiation MR unsafe BF type application part Class II equipment Indoor use only Keep away from rain Upper and lower Humidity limits to be temperature limits to be...
  • Page 13: Technical Description

    6. Technical Description 6.1 Classification of electrical safety 1. Classification by type of electric-shock prevention: a) Charging system: device powered by external power supply--Class II, b) ITM and BTE: device powered by internal power supply. 2. By degree of electric-shock prevention: BF type device. 3.
  • Page 14 Safety features of wireless technology for SoundBite Hearing System include: Patient-specific information is not stored in BTE or ITM. The wireless signal of SoundBite Hearing System is only close to the user's head, so any interference to the system requires a very close distance.
  • Page 15: Warranty

    6.6 IP classification description classification Brief description Definition IPX0 Non-protected — Vertically falling drops shall When the vertical planes of have no harmful effects the ear-back machine are when the enclosure is tilted IPX2 inclined at 15 degrees, the at any angle up to 15″ on vertical drip should have no harmful effect.
  • Page 16: Emc Compliance Statement

    Guidance and Manufacturer's Statement--Electromagnetic Emission The SoundBite Hearing System is expected to be used in the following specified electromagnetic environment, and the purchaser or user shall ensure that it is used in this electromagnetic environment:...
  • Page 17 Guidelines and Manufacturer's Statement--Electromagnetic Immunity The SoundBite Hearing System is expected to be used in the following specified electromagnetic environment, and the purchaser or user shall ensure that it is used in this electromagnetic environment: Basic EMC standard or test...
  • Page 18 0% U : 1 cycle and 70% U : 25/30 cycles sine phase at 0° Voltage interruptions IEC 61000-4-11 0% U : 250/300 cycle : rated voltage(s); E.g. 25/30 cycles means 25 cycles at 50Hz or 30 cycles at 60Hz 18 / 20...
  • Page 19 When they are used in close proximity to medical equipment and/or systems, the medical equipment and/or systems’ basic safety and essential performance may be affected. This SoundBite Hearing System has been tested with the immunity test level in the below table and meet the related requirements of IEC 60601-1-2:2014.
  • Page 20 Warning: SoundBite Hearing System may not be used close to or superimposed on other devices. If it must be close to or superimposed in use, it shall be observed and verified that it can operate normally under the configuration applied.
  • Page 21: Parts List

    9. Parts List Part name Number Instructions Standard Certificate of quality Standard User delivery table Standard Quick operating guide Standard Portable box Optional CE2460 EC Representative: Llins Service & Consulting GmbH Address: Am Heiligenhaus 7, 69126, Heidelberg, Germany Tel: +49 176 63866127 Manufacturer: Sonitus Medical Shanghai Co., Ltd.
  • Page 22 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This manual is also suitable for:

G3s