6.1. PC Hardware Requirements ................14 6.2. Software Installation ..................15 6.3. Connecting MicrUs Pro to PC ................ 22 6.4. Running Echo Wave II Software ..............22 6.5. Additional Recommendations for Cybersecurity ..........24 Maintenance, Cleaning and Disinfecting ............... 26 7.1.
Page 3
MicrUs Pro User Guide Troubleshooting Q&A ................... 33 Warranty and Service Information ................ 33 12.1. Warranty......................33 12.2. Warranty Shipments and Returns ..............33 12.3. Obtaining Device Serial Number ..............34 12.4. Service Contract ..................... 35 - 3 -...
• Light weight, true mobility, fits the size of ordinary transducer. Here in User Guide you can find a common information about the MicrUs Pro system, how to assemble the components and install the software, safety and maintenance information. Operation Manual contains Echo Wave II software description for Windows- based device users and Echo Wave A for Android device users.
Trained professionals should perform diagnostic ultrasound procedures safely for the intended purpose. The MicrUs Pro and its thermal (TI) and mechanical (MI) safety limits are set to industry standards, as a Track 3 device, and are not displayed on the display screen, because they are not exceed the value of 1,0 at any given time, based on the all possible setting configurations as per IEC 60601-2-37.
MicrUs Pro User Guide 2.3. Electromagnetic Conformance (EMC) The MicrUs Pro system is intended to enable diagnostic ultrasound imaging and measurement of anatomical structures and fluids by qualified and trained healthcare professionals. Electromagnetic fields, however, can cause distortion or degradation of this information, affecting this performance.
Page 7
135°,180°, 225°, 0°, 45°, 90°, interruptions hospital environment. If the 270° and 315° 135°,180°, and voltage user of the MicrUs Pro system 225°, 270° variations on 0% UT; 1cycle and requires continued operation and 315° power supply 70% UT; 25/30...
Page 8
MicrUs Pro User Guide Recommended separation distances between portable and mobile RF communications equipment and the MicrUs Pro system Rated maximum Separation distance according to frequency of transmitter, m output power of transmitter, W 150 kHz to 80 MHz 150 kHz to 80 MHz...
Page 9
MicrUs Pro User Guide Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment Test Band Service Modulation Distance IMMUNITY Compliance frequency (MHz) power TEST level (MHz) LEVEL (V/m) (V/m) 380 – TETRA 400 Pulse modulation 18 Hz 430 –...
MicrUs Pro User Guide Labeling 3.1. Symbols You can find several symbols on your medical product and its packaging that classify a connection, warn of potential hazards or indicate kind of information presented. Below is a table of these symbols with explanation of their meaning.
MicrUs Pro User Guide System Overview The MicrUs Pro system is a combination of ultrasound transducer and an ultrasound beamformer in one compact handheld device. The complete system consists of: • The MicrUs Pro device • USB cable connecting device with controlling and visualizing device •...
MicrUs Pro User Guide 5.3. Connecting Android System Connect the MicrUs Pro to your Android phone or tablet with USB cable included. Ensure that Android device is well charged before you start scanning. MicrUs Pro Android Connection Diagram When the MicrUs Pro is not in use it is recommended to disconnect the cable from your mobile device to save the battery charge.
Page 13
The first time you run Echo Wave A it brings the following message, asking if you would like to start Echo Wave A automatically when your MicrUs Pro scanner is connected. Set check box and tap OK button if you agree.
MicrUs Pro User Guide During long continuing uses of ultrasound system the mobile phone can be internally overheated that can result with a popup message like shown below. If that happens then allow phone to cool down switching it off or at least closing all running applications for a reasonable amount of time.
• Microsoft .NET Framework 3.5.1 6.2. Software Installation Ensure that the software you have supports your device. At time of writing the MicrUs Pro is supported by: • Echo Wave II ver.4.0.1b22 and higher • Telemed Drivers Package ver. 2.0.1b26 and higher 1.
Page 16
MicrUs Pro User Guide Select MicrUs checkbox, click “Next >” Click “Next >” - 16 -...
Page 17
MicrUs Pro User Guide Wait until all files are copied to your hard drive… Click “Finish”. - 17 -...
Page 18
MicrUs Pro User Guide 3. Go to \\Software Installation\Echo Wave II ver.XXX\ folder and run setup_ew2.exe Installation windows will appear. Click “Next >” Choose “I agree to overwrite all presets and settings”, click “Next >” button - 18 -...
Page 19
MicrUs Pro User Guide Select your region and click “Next >” button Click “Next >” button - 19 -...
Page 20
MicrUs Pro User Guide Click “Next >” button Click “Next >” button - 20 -...
Page 21
MicrUs Pro User Guide Wait till all files will be copied Click “Finish” - 21 -...
MicrUs Pro User Guide 6.3. Connecting MicrUs Pro to PC Connect ultrasound device to PC with included USB cable. Wait until Windows will finish device setup. PC connection diagram 6.4. Running Echo Wave II Software 1. Make sure, that “Ultrasound Scanner Monitor” utility icon in tray bar is lightened GREEN.
Page 23
MicrUs Pro User Guide Echo Wave II software launch icon Software start-up in progress Software / system ready for use. Note: Picture shows image from the MicrUs Pro-C60S - 23 -...
MicrUs Pro User Guide 3. Further information and step by step instructions can be found in Echo Wave II Software User Manual located on this USB key. 6.5. Additional Recommendations for Cybersecurity Configure Windows: • E-mail Configure the e-mail program (for example Outlook Express). It is necessary for normal operation of the direct e-mail sending feature of the ultrasound software.
Page 25
MicrUs Pro User Guide • Updating your Microsoft antimalware and antispyware software https://www.microsoft.com/security/portal/definitions/adl.aspx • Firewall It is strongly recommended that on computer will be turned on Windows Firewall. How to Configure Windows Firewall on a Single Computer https://msdn.microsoft.com/en-us/library/cc875811.aspx • Windows updates It is strongly recommended that computers will have turned on Windows Updates.
7.1. General Maintenance Rules Please keep in mind that the MicrUs Pro is a sophisticated electronic device. It needs a careful handling. Always keep the device in a safe storage place when not in use. Avoid cases of a fall or a stress of the device. Do not allow excessive bending of the cable.
Before low-level disinfecting procedure clean MicrUs Pro according to the procedure described in Chapter 7.3 Cleaning MicrUs Pro. Observe warnings and cautions. After cleaning, choose a low-level disinfectant that is compatible with MicrUs Pro. For a list of compatible disinfectants, see Chapter 7.6 List of Compatible Disinfectants.
Follow the label instructions for preparation, temperature, solution strength, and duration of contact. Do not use expired disinfection solutions as their effectiveness is not guaranteed. When disinfecting in a solution do not immerse MicrUs Pro more than shown on a picture below. Immersing MicrUs Pro Using an appropriate disinfectant for the USB cable, wipe or spray the cable and USB connector, following disinfectant label instructions.
MicrUs Pro User Guide Cidex Plus High-level Disinfection Immersing Read instructions Intermediate Level Disinfection carefully Specifications 8.1. Mobile Device Requirements System requirements • Mobile phone or tablet with USB OTG (USB On-The-Go) port (Type-C or Micro USB) • Android operating system (versions from 6.0 to 10.0) •...
8.4. List of Parts and Accessories Below is the list of parts and accessories that belong to MicrUs Pro family. Part name Description MicrUs Pro-C60S...
• Atmospheric pressure: 70 - 106 kPa Transportation, Storage and Disposal The MicrUs Pro system is supplied packed in a custom foam lined hard carton box for safe transportation. The device can be stored in original packaging or in specially organized storage location.
24 months (or 18 months for probes) and labor for 90 days. In order to comply with this warranty, all service must be performed by a TELEMED qualified field engineer or only with the express permission of TELEMED. Items not included in this warranty are misuse, negligence or accidental damage.
System Information tool will collect information about your system which you can save as a text file and provide to TELEMED support. To get the device serial number go to the end of a text file and search for the label “Probe Serial Number”. The value of this label is your device’s serial number.
12.4. Service Contract A service contract may be obtained for the TELEMED after the original warranty or guarantee period has expired. The contract provides for any service calls that may be necessary to keep the system operational and will include at least one regularly scheduled service visit per year.