This operating manual allows you to acquaint you with CONTENTS Page the device and operation of the IN-01m metal mechanical stress indicator (hereinafter referred to as the stress indicator) 1. Purpose ................4 and sets the rules for its operation, transportation and storage, 2.
1.8. According to the operating conditions, the stress 2.7. Time to set the metal stress indicator's operating indicator belongs to the type of climatic version of UHL 3.1 mode, s, not more than: - 10 according to GOST 15150-69 and can work steadily when: 2.8.
3.3. The appearance of the stress indicator with a Sensor and a magnetizing unit is shown in Fig.3.2. Fig.3.1. Block diagram of IN-01m the metal stress indicator 1 – magnetizing device, 2 – integrated Hall effect sensor chip, 3 – pulse voltage stabilizer, 4 – scaling amplifier combined with a low-pass filter, 5 –...
Page 5
Fig.3.3. Location of controls and connectors of the battery (battery). electronic unit of IN-01m the metal stress indicator 4 – alphanumeric liquid crystal display, 5 – power 3.4. The purpose of the controls of stress indicator button, 6 –...
Page 6
Using of the IN-01m Connect software application pre- installed on a personal computer, the measured information from the stress indicator's electronic memory is transmitted over a cable and stored in the personal computer's memory.
5.1.5. In low light conditions, to improve the visibility 4. SAFETY INSTRUCTIONS 4.1. Persons who have studied sections 2-5 of this of the stress indicator screen, turn on the screen backlight operating manual, as well as those who have received button.
Fig.6.1. Message on IN-01m the stress indicator about Note: lateral displacement of the magnetic pole of the the need to charge or replace the battery...
Page 9
Writing. The measured data is saved to the built-in memory card of the IN-01m metal mechanical stress indicator in files of the Fig.6.3. Indication of data exchange of the IN-01m DDMMYYYY type CSV, where DD is the current day, MM is metal stress indicator with a personal computer via USB the month, and YYYY is the year.
disconnect the cable from the mini-USB connector of the 8. TROUBLESHOOTING electronic indicator unit. 8.1. Possible malfunctions and ways to fix them are shown in table 8.1. 7. MAINTENANCE SERVICE Table 8.1. Possible Probable cause Remedy 7.1. Maintenance of the stress indicator is performed by malfunction technical personnel from the departments of the control and When the power is...
9. TRANSPORTATION AND STORAGE RULES Possible Probable cause Remedy malfunction 9.1. The stress indicator must be transported in a When installing the There is a break Find the place of package with the battery disconnected from the electronic unit. sensor on a metal in the connection the break and, if 9.2.
Need help?
Do you have a question about the IN-01m and is the answer not in the manual?
Questions and answers