9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual CONTENTS NOS. PAGE GENERAL NOTES THE SOFTENING PROCESS In Service Regeneration The Regeneration Process Meter Control of Regeneration Initiation Duplex Operation UNPACKING AND PARTS IDENTIFICATION Basic Packages Unpacking Notes Missing or Damaged Goods TEMPORARY STORAGE DESCRIPTION OF PLANT COMPONENTS Nitrate Removal Vessel and Internals...
Page 3
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual NOS. PAGE ASSEMBLY/INSTALLATION Mechanical 7.1.1 Assembling Vessel, Riser Tube and Internals 7.1.2 Charging the Resin 7.1.4 Assembling the Control Valve 7.1.5 Attatching the Control Valve and Slave Adapter 7.1.6 Brine System 7.1.7 Pipework 7.1.8 Storage tank ball valve 7.1.9 Drains and Overflow Connections Electrical...
Page 4
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual NOS. PAGE OPERATION Normal Operation Refilling with Salt Manual Regeneration By-passing the Nitrate Removal Temporary Shut-down Changes in Incoming Water Routine Monitoring 10.0 FAULT FINDING AND RECTIFICATION 10.1 No Flow to Service 10.2 Poor Treated Water Quality 10.3 No Regeneration 10.4 Unsatisfactory Capacity between Regeneration’s 11.0 WARRANTY AND SERVICE...
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual GENERAL NOTES These instructions cover the 9000/9100/9500 Range of Duplex Water Softeners, which includes models ranging in size from 20-120 litres resin volume fitter with ¾” – 1.1/2” Mechanical Meter/Timer or SXT Electronic Meter/Timer.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual THE SOFTENING PROCESS Hardness in water is caused by the presence of dissolved salts of Calcium and Magnesium. In order to overcome the problems associated with the use of hard water, these salts must be removed. This process is called 'Softening'.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual THE REGENERATION PROCESS The regeneration process consists of four stages:- Backwash - Water flows upwards through the resin bed, and out to a drain. As it does so, it loosens the ion exchange beads, removes any resin 'fines' (i.e.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual DUPLEX OPERATION A 'Duplex' system is a means of operation to achieve a constant flow of soft water to service, without the need for extensive treated water storage. The system is essentially two vessels, which are connected to common inlet and outlet pipework, and which are in service alternately.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual UNPACKING AND PARTS IDENTIFICATION BASIC PACKAGES The Nitrate Removal will be delivered in a number of packages which include a pair of glassfibre reinforced pressure vessels, a control valve, slave valve adapter, interconnecting hoses, a brine tank, an even number of 25 litre bags of resin with possibly two additional part bags, and a funnel to fill the vessels.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual DESCRIPTION OF PLANT COMPONENTS NITRATE REMOVAL VESSEL AND INTERNALS The pressure vessel which contains the ion exchange resin is made from a fibreglass/epoxy resin outer layer surrounding an inner, seamless shell made from Polyethylene, Polypropylene or ABS.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual BRINE SYSTEM The brine system consists of a moulded polyethylene tank into which the brine well and brine pick up are assembled. The tank forms the salt storage container. The brine pick-up tube within the brine well is connected to the pipe from the control valve which sucks the brine from the tank.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual PRE-INSTALLATION MECHANICAL 6.1.1 Foundation/Drainage The Nitrate Removal will not require any special foundations, provided that a firm, level area which is capable of supporting the working weight is available. (See Engineering Data, Section 12.2) Unwanted water from the regeneration process must flow to drain, and so an open drain or gully, capable of passing the necessary flow is required (see Process and Operating Data, 12.1, for relevant flows).
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 6.1.4 Pipework Pipework to be connected to the Nitrate Removal should not have an excessive amount of hardness scale deposit. Piping that is heavily built up with scale (or Iron deposits) should be replaced. Make sure that the pipework can be connected to the Nitrate Removal in such a way as to impose no stresses on the control valve, and that it is properly aligned and supported.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual ASSEMBLY/INSTALLATION MECHANICAL Check all the items against the parts list and shipping documents, and ensure you have them all before starting work. In addition to the Nitrate Removal you will require installation materials and basic tools, (i.e., spanners, screwdrivers etc., and PTFE tape) 7.1.1 Assembling Vessel, Riser Tube and Internals The larger units are shipped as pre-assembled components to reduce the...
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 7.1.4 Assembling the Control Valve Carefully remove the control valve and the slave tank adapter from their packing, and check that all parts are present. On the 9000 and 9100 valves, snap in the bayonet fit distributors to the control valve and slave tank adapter.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual making due allowance for the pressure drop between the Nitrate Removal and the point of discharge of soft water. NOTE: IF BRAZED OR SOLDERED FITTINGS ARE TO BE USED, THE PIPEWORK MUST BE DISCONNECTED FROM THE VALVE DURING HEATING AND COOLING.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual ELECTRICAL Electrical installation is very straightforward, but should still be carried out by a competent electrician, and must conform to the appropriate standards of safety. 7.2.1 Mains Supply The mains supply should be through a separate, switched supply, fused and earthed in accordance with Institute of Electrical Engineers Regulations.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual COMMISSIONING INTRODUCTION It is recommended that the commissioning of the plant is undertaken by a trained service engineer, who will be able to put the plant into service quickly, and most efficiently. However, if the services of an experienced engineer are not available, following the steps outlined below will result in the system being properly commissioned.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual Press the extra cycle button to set the regeneration override. The default is 3 days for duplex softeners. This may be changed to a different interval by pressing the up and down arrows. Press the extra cycle button to exit the Site Programming mode.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual PRE-SERVICE FLUSH AND REGENERATION – MECHANICAL TIMERS Set the manual isolating valves so that water will by-pass the Nitrate Removal. Turn on the main water supply. Open a soft water tap close by and let the water run for a few minutes to flush out any debris or foreign matter from the pipework system.
Page 21
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual amount of water has refilled into the brine tank. Finish off by indexing the knob to the home position. This has now commissioned both vessels and the system is ready for service. 'Close' the timer so that the support leg snaps into the backplate. Adjust the capacity of the Nitrate Removal if necessary using the reference sheet attached.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual PRE-SERVICE FLUSH AND REGENERATION – SXT TIMERS Set the manual isolating valves so that water will by-pass the Nitrate Removal. Turn on the main water supply. Open a soft water tap close by and let the water run for a few minutes to flush out any debris or foreign matter from the pipework system.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual OPERATION NORMAL OPERATION Operation is completely automatic, with regeneration being initiated whenever required by the meter controller. REFILLING WITH SALT Since salt is used in the regeneration process, the level of salt in the brine tank will fall after each regeneration.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual TEMPORARY SHUT-DOWN If the Nitrate Removal needs to be taken out of service for some time for any other reason, it is recommended that one or two simple procedures be undertaken to ensure the return to operation is as smooth as possible. The unit should be left with both columns fully regenerated regenerated.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual ROUTINE MONITORING The following recommendations are made to help the user of the Nitrate Removal confirm that it is performing as required, and to give early warning of possible problems. The operation of the Nitrate Removal is completely automatic, and should not require adjustment (except as above).
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 10.0 FAULT FINDING AND RECTIFICATION Modern water softeners are extremely reliable and unlikely to give any problems if they are installed and operated correctly. 10.1 NO FLOW TO SERVICE Check mains pressure is above 1.7 bar. Check inlet and outlet isolating valves are open.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 10.3 NO REGENERATION Check electrical supply, fuses etc. satisfactory. Check control head motor runs, by initiating a manual regeneration. Replace if necessary. 10.4 UNSATISFACTORY CAPACITY BETWEEN REGENERATIONS See Section 10.2. Check condition of resin. Resin may have become fouled, inhibiting the regeneration process.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 11.0 WARRANTY AND SERVICE 11.1 AFTER SALE WARRANTY Your Nitrate Removal is covered by a parts warranty for a period of one year from installation. Should you have any problems with your Nitrate Removal or require routine service, please contact your supplier.
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.1 PROCESS AND OPERATING DATA 12.1.1 9000/9100 Series Water Softeners 20-60 litre MODEL 20 L 25 L 30 L 40 L 50 L 60L PARAMETER UNITS Max. Service M3/hr 0.80 1.00 1.20 1.60 2.00 2.40 Flow Min Service M3/hr...
Page 30
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.1.2 9000/9100 Series Water Softeners 80-150 litre (9100 80L ¾” only) MODEL 80 L 100 L 120 L 140L 150L PARAMETER UNITS ¾” Max. Service M3/hr 3.00 3.00 3.00 3.00 3.00 1” Flow 3.20 4.00 4.00 4.00 4.00 Min Service M3/hr...
Page 31
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.1.3 9000 Series Water Softeners 190-250 litre MODEL 190 L 200 L 250L PARAMETER UNITS Max. Service M3/hr 3.20 4.00 4.00 Flow Min Service M3/hr 0.95 1.00 1.25 Flow Capacity m3 Volume treated between regens 31.6 33.3 41.6 (300 ppm CaCO3, 21...
Page 32
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.1.4 9500 Series Water Softeners 100-150 litre MODEL 100 L 120 L 140L 150L PARAMETER UNITS Max. Service M3/hr 4.00 4.80 5.60 6.00 Flow Min Service M3/hr 0.50 0.60 0.70 0.75 Flow Capacity m3...
Page 33
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.1.5 9500 Series Water Softeners 190-350 litre MODEL 190 L 200 L 250L 300 L 350 L PARAMETER UNITS Max. Service M3/hr 7.60 8.00 8.40 8.40 8.40 Flow Min Service M3/hr 0.95 1.00 1.25 1.5 1.75 Flow Capacity...
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.2 ENGINEERING DATA 12.2.1 9000/9100 Series Water Softeners 20-60 lit MODEL 20 L 25 L 30 L 40 L 50 L 60 L PARAMETER UNITS Diameter of vessel/valve Height to top of valve 1084 1085 1085 1304 1567 1418 Diameter of brine tank Height of brine tank...
Page 35
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.2.2 9000/9100 Series Water Softeners 80-150 lit MODEL 80 L 100 L 120 L 140 L 150 L PARAMETER UNITS Width of vessel/valve Height to top of valve 1561 1850 1850 1850 1850 Diameter of brine tank Height of brine tank 1170 1100 1200 1200 1200...
Page 36
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.2.3 9000MI Series Water Softeners 190-250 lit MODEL 190 L 200 L 250 L PARAMETER UNITS Width of vessel/valve Height to top of valve 1990 1850 1850 Diameter of brine tank Height of brine tank 1240 1240 1240 Inlet Conn.
Page 37
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.2.4 9500 Series Water Softeners 100-150 lit MODEL 100 L 120 L 140 L 150 L PARAMETER UNITS Width of vessel/valve Height to top of valve 1850 1850 1850 1850 Diameter of brine tank Height of brine tank 1100 1200 1200 1200 Inlet Conn.
Page 38
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 12.2.5 9500I Series Water Softeners 190-350 lit MODEL 190 L 200 L 250 L 300 L 350 L PARAMETER UNITS Width of vessel/valve Height to top of valve 1990 1850 1850 2000 2000 Diameter of brine tank 1050 1050 Height of brine tank...
9000/9100/9500 Duplex Series 13.0 Factory Programming 13.1 Regeneration Settings See master Programming chart 13.2 Nitrate Removal output (capacity) When sizing a Nitrate removal capacity base the capacity on a combined Nitrate and Sulphate number. 9xDXIOMM\page 39...
Page 40
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 13.3 Master Program Settings – SXT valves only Master Program set up summary – 9000/9100 valves Set to 12:01 and hold up and down button down together Parameter Disp Value description Display Format Valve Type dF1b Control Type...
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual Parameter Disp Value description Display Format Valve Type dF1b Control Type Number of Tanks Tank in Check service Tank Arrow Unit capacity 1000 1250 1500 1750 across Feedwater Hardness Reserve Selection Safety Factor Day Override ...
Page 42
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 13.4 Master Program Settings – SXT valves only Master Program set up summary – 9500 valves Parameter Disp Value description Display Format across Valve Type dF1b Control Type Number of Tanks Tank in Check service Tank...
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual Parameter Disp Value description Display Format Valve Type dF1b Control Type Number of Tanks Tank in Check service Tank Arrow Unit capacity 1.75 across Feedwater Hardness Reserve Selection Safety Factor Day Override ...
9000/9100/9500 Duplex Watersoftener Installation Operation Maintenance Manual 14.2 Installation Layout Fig 1 General Installation Layout 9000 Duplex Softeners Hard Drinking Water supply Mains Isolating Bypass Valve Valve Soft Water Outlet Hard Water Outlet Inlet Double Inlet Isolating Isolating Check Valve Valve Valve Pressurised...
Page 47
9000/9100/9500 Duplex Series Manufacturer's Declaration of Conformity We the undersigned EURAQUA UK, HITCHIN, ENGLAND Certify that the product _____________________________________________________________________ type: DUPLEX WATER NITRATE REMOVAL WITH FLECK 9000/9100/9500 24 VOLT AC VALVE _____________________________________________________________________ has been designed and manufactured in accordance with the...