Download Print this page

Advertisement

Quick Links

DS0052V Cellio LTE BLE Gateway User Manual
DS0052V
User Manual
06/03/2021
1
www.cellio.io

Advertisement

loading

Summary of Contents for Cellio DS0052V

  • Page 1 DS0052V Cellio LTE BLE Gateway User Manual DS0052V User Manual 06/03/2021 www.cellio.io...
  • Page 2: Table Of Contents

    1. FCC/ISED Statements ........................3 2. Introduction ............................ 4 3. Supported Connections ........................4 4. DB9 I/O Support and Pinout ......................5 5. BLE 5.0 Sensor Connection and Cellio Bluetooth App ............... 7 5.1. Signal Strength Readings: ........................8 6. Support ............................9 www.cellio.io...
  • Page 3: Fcc/Ised Statements

    Pour se conformer aux exigences de conformité CNR 102 RF exposition, une distance de séparation d'au moins 20 cm doit être maintenue entre l'antenne de cet appareil et toutes les personnes. www.cellio.io...
  • Page 4: Introduction

    ISM 915 MHz wireless connection to a compatible Cellio ISM 915 MHz Transceiver which is directly wired to sensors which support the specification of the I Cellio ISM 915 MHz Transceiver I/O. Refer to the Cellio Transceiver datasheets for supported I/O.
  • Page 5: Db9 I/O Support And Pinout

    Figure 1: Three ways to Connect IOT Sensors to the Gateway 4. DB9 I/O Support and Pinout The IP67 Gateway male DB9 connector pinout is defined in Figure 2. www.cellio.io...
  • Page 6 DB9 Pin I/O Function Sensor Report Default Mapping* VEXT_5.0 Analog Input Sensor Report 2, reading_0 Future Use Analog Input Sensor Report 2, reading_1 Future Use Future Use Future Use * Refer to “Cellio Universal Protocol” (CUP) specification for further details www.cellio.io...
  • Page 7: Ble 5.0 Sensor Connection And Cellio Bluetooth App

    BLE sensors communicate with the Gateway. Figure 3: Cellio Bluetooth App Environment Refer to Figure 3. The Cellio Bluetooth App is hosted on your secure server and accessed from a Bluetooth enabled device (PC, tablet, smartphone). The device must be compliant with Bluetooth 4.0 however, compliance with 4.2 with Data Length Extension (DLE) is recommended for improved...
  • Page 8: Signal Strength Readings

    Erase Gateway Report Queue o Reboot Gateway  A list of each BLE sensor or Cellio Transceiver connected to the Gateway since the last gateway reset with the following: o Sensor ID o Time elapsed (minutes) since last connection o Signal Strength Reading 5.1.
  • Page 9: Support

    Figure 4: Sample Screen Capture of Gateway Diagnostic App 6. Support Enter support issues into Cellio Zendesk per your established account (if applicable). Otherwise, if you do not have and established Cellio Zendesk account, email support issues to Cellio Support at support@cellio.zendesk.com.