Contents Security 2 Brief Introductions to the Product 2.1 Model and the Nameplate of the Product 2.2 The List Table of the YTB-S-LT Series Product 2.3 Appearance of the Product 2.4 Performance Index 3. Installation and Wiring 3.1 Installation 3.2 Terminals Explanation 3.3 System Wiring 4.
Yatai Inverter YTB-S-LT User’s Manual 1. Security Danger ! ★ Converter will be installed in the place, where the absence of flammable and explosive gas was strictly prohibited, else may cause to an explosion. ★ Only can the professionals operate the converter in installation, wiring operating and maintenance, otherwise may be to endanger the property and the personal safety.
Page 4
Yatai Inverter YTB-S-LT User’s Manual ● Strictly prohibit connecting the input power line to the terminals U、 V、 W、 U1、 V1 and W1. Otherwise it will damage the converter and may cause fire disaster. ● The wiring line of control loop should be separated far from the power line each other; otherwise it may affect the normal status of the converter or other devices.
Yatai Inverter YTB-S-LT User’s Manual 2. Brief Introductions to the Product 2.1 Model and the Nameplate of the Product The model example of the YTB-S-LT series frequency converter is shown in Figure 2-1, the nameplate example is shown in Figure 2-2 (here, we take the 0.4KW single-phase input converter as the example).
Yatai Inverter YTB-S-LT User’s Manual YTB-S-LT-0.75K Wind 0.75 Cooling 2.3 Appearance of the Product The upper casing of the YTB-S-LT series converter is made of plastic and the lower casing is a structure made by cast aluminum, its appearance is with the characteristics of beautiful shape,high-intensity, toughness and fast cooling and shown in Figure 2-3.
Page 7
Yatai Inverter YTB-S-LT User’s Manual Frequency Setting Digital Setting: 0.01Hz Accuracy Vector modulation for Optimization of Space Modulation Mode Control Type V/F Curve 18 Compensating Curves PI Control Internal PI Controller to Facilitate the Automatic Control 1)Speed Adjusting with Decreasing Frequency Winding 2)PI Speed Adjusting...
Yatai Inverter YTB-S-LT User’s Manual 3. Installation and Wiring 3.1 Installation 3.1.1 The Installation Direction and Space In order to benefit the heat dissipation of the converter, it is needed that installation of the converter must in vertical direction (as shown in Figure 3-1); and must guarantee sufficient ambient ventilation space. The table 3-1 gives out the size of clearance space for installing the converter (recommended value).
Page 9
Yatai Inverter YTB-S-LT User’s Manual 3.2.1 Explanation of the Power Terminals Figure 3-2 Diagram of the Power Terminals Table 3-2 Explanation of the Power Terminals Terminal Name Terminal Label Explanation of the Terminal Function Terminals for Single Phase 220V Alternative Terminals of Power Input L1、L2...
Page 10
Yatai Inverter YTB-S-LT User’s Manual Operation OUT2 Used to Indicate Operation Indicating Signal The Signal Input for the Terminal Input Terminal Reserved Input Tension Control Auxiliary Power Output and Input Terminals, Power +12V Control Power the Common Terminal of the...
Yatai Inverter YTB-S-LT User’s Manual 3.3 System Wiring 3.3.1 Basic Wiring Diagram of the converter ~220V Tension RUN FWD DGT FRQ control Signal input 方式 ▲ 运行 设置 ▼ 停复 Yarn broken OUT1 OUT2 Pulse Hall Driver Board of Stepper...
Page 12
Yatai Inverter YTB-S-LT User’s Manual 3.3.2 Reference of the Loop Wiring Table 3-4 Loop Wiring Reference Table Power Primary Rating Input Circuit Converter Model Input Capacity Output Output Current Power Current (A) Wiring Single Phase 0.4KW 220V,1KVA YTB-S-LT-0.4KW Single Phase 0.75KW...
Yatai Inverter YTB-S-LT User’s Manual 4. Operation and Display 4.1 Keyboard Controller 4.1.1 Explanation of the Operating Panel size and appearance of the controller keyboard of YTB-S-LT series frequency converter can see the note of Figure 4-1. . LED display operating frequency (velocity), function code, parameter value, length or fault code Four light-emitting diodes display the operative mode.
Yatai Inverter YTB-S-LT User’s Manual From “Function Code Edit” display mode to the display mode of “Function 设置 Code Parameter Modifying”, then in the “Function Code Parameter “Setting” key Modifying” display mode, this key is used for data storage and returning to the “Function Code Edit”...
Page 15
Yatai Inverter YTB-S-LT User’s Manual Push the“▲/▼”key to modify the selected data place. ▲ 2000 ▼ Push the “Setting” key to store the setting data and return to the current function code. 0-05 设置 方式 Push the “Mode”key to display function code, but the changed value is invalid.
Yatai Inverter YTB-S-LT User’s Manual 参数设置成功 Success of parameter setting 4.3 Illustration of the Display Items Table 4-3 List of the display Items Display Item Illustration Process of the power on to reset, after reset the value of length is displayed.
Page 17
Yatai Inverter YTB-S-LT User’s Manual When display the Extra-feeding parameters, the indicator FRT on panel is bright. Notice: When the Fault information is emerged, it is needed firstly to analyze and examine the cause of the Fault, please don’t run the “Reset” operation immediately.
Yatai Inverter YTB-S-LT User’s Manual 5. Parameters and Function Codes YTB-S-LT Series specific winding converter provides users with the following function parameters. By modifying the value of these parameters, the frequency converter can meet various requirements of users. 5.1 Zoom Table of the Parameters and Function Codes...
Page 19
Yatai Inverter YTB-S-LT User’s Manual 0-10 Preservation × PI Control Coefficient 1-00 1~20 × 1-01 PI Control Time Second 0.1~10.0 × Meter/ Target Velocity 1-02 80~1200 × Minute 1-03 Roller Diameter 10.0~50.0 22.0 × 1-04 Bobbin Diameter 40.0 30.0~200.0 ×...
Page 20
Yatai Inverter YTB-S-LT User’s Manual Function Code 3 District is Invalid Time for Beginning 4-00 × 0.0~20.0 Detect the time of Yarn broken Is or not Machine 0:Yes 1:No 4-01 × Halt for no pulse? 2:Internal Counting Delay Machine 4-02 ×...
Page 21
Yatai Inverter YTB-S-LT User’s Manual with the Yarn broken Signal Delay Time for 4-10 10.0 × 0.1~300.0 Beginning of the PI Control Protected Value for 4-11 m/min × 20~100 the PI Control 0: No Voltage Output Type of Outputting 1: Outpu Fixed Value 4-12 ×...
Page 22
Yatai Inverter YTB-S-LT User’s Manual wheel Diameter Extra-feeding 5-03 √ 0.1~300.0 Acceleration Time Extra-feeding 5-04 0.1~300.0 √ Deceleration Time Extra-feeding 5-05 × 2~10 Carrier Frequency Extra-feeding Torque 5-06 × 1~18 Compensation 0: Machine Halt with Selection of the Deceleration Extra-feeding 5-07 √...
Yatai Inverter YTB-S-LT User’s Manual Frequency Increment of the 5-11 √ 1~200 winding length Value Extra-feeding increased velocity 5-12 m/min √ 0.0~8.0 Velocity Track 5-13 1.00~4.00 1.20 √ Coefficient Extra-feeding 5-14 0.00~25.00 0.00 × Start-up frequency Extra-feeding 5-15 √ 0~60...
Page 24
Yatai Inverter YTB-S-LT User’s Manual modified. The Factory Value of the password is 8; the user can set it with another number by his desire. After modifying, please save valid password properly. 0-01 Acceleration Time Setting Range: 0.1~300.0S Factory Value: 3.0 Acceleration time is the time of the period from 0Hz to 50 Hz in beginning operation of the converter.
Page 25
Yatai Inverter YTB-S-LT User’s Manual 0-05 Length Setting Setting Range: 100~9999 Factory Value: 1000 This parameter refers to the length of spinning yarn, used together with 1-05 and 2-02, can set different spinning length, see the function introduction of 0-05 and 2-05 for details.
Page 26
Yatai Inverter YTB-S-LT User’s Manual Values, that is to say, if choosing its value as 1, then pushing the setting key can make all the parameters restore to their Factory Values. During the process of restoring the Factory Values, the “dT...” is displayed to express the data are in transferring: “data transferring”.
Page 27
Yatai Inverter YTB-S-LT User’s Manual beginning time, and then PI control the velocity. For instance: if 1-04 is set up to 40.0 mm,1-02 is set up to 300m/min, then if 1 Hz is estimated according to 30 R/min, the target frequency for beginning operating is 300*1000/40.0/30/3.14=79.62Hz.
Page 28
Yatai Inverter YTB-S-LT User’s Manual of the converter at the beginning of spinning (Spindle Empty). Along with the changing of the spinning length, the frequency is also decreasing as well. If the machine halts without full yarn, then the target frequency at operation of the next time is just the frequency at the time of machine halt.
Page 29
Yatai Inverter YTB-S-LT User’s Manual operating will be according to a general constant frequency and together with the diameter increasing of yarn bobbin, the velocity of the yarn also gradually increases as well. However the Figure B adopts the operating mode of increasing progressively from the Stopping Frequency to the Starting Frequency, it can increase the velocity of the yarn effectively and make the efficiency of spinning able to be improved obviously.
Page 30
Yatai Inverter YTB-S-LT User’s Manual frequency, the operation process is shown in the Figure below. Setting up the 2-03 and 2-04 must ensure (2-03)-(2-04)>0.50Hz, otherwise the lowest operating frequency is 0.50Hz and bring about the cycle period inaccurate. While setting up the parameters, the acceleration and deceleration time are easy to be too long.
Page 31
Yatai Inverter YTB-S-LT User’s Manual Function Code 4 District 4-00 Delay Detect the Yarn Factory Value:3.0 broken Time Setting Range:1.0~20.0 S Because at the beginning of the converter’s operation the yarn is still up on the spindle, the sensor for yarn broken would account the yarn has been break, this parameter must be set up to make the converter not treat the signal of yarn broken in this period of time.
Page 32
Yatai Inverter YTB-S-LT User’s Manual 4-03 is set up to “0”, then when machine halt or yarn broken, between OUT1 and 12V there are several seconds output; if 4-03 is set up to “1”, there are several seconds output when yarn is full. The output time is set up by 4-04.
Page 33
Yatai Inverter YTB-S-LT User’s Manual can adjust it according to his requirements. 4-11 Protection Value of PI Setting Range:20~100 m/min Factory Value:50 Control The Function Code 4-11 means that when the difference between the target velocity and the actual velocity exceeds the setting value of 4-11, the converter will jump to the protection of Err2.
Page 34
Yatai Inverter YTB-S-LT User’s Manual Frequency (Function code 5-09) until to the Extra-feeding Stopping Frequency (Function Code 5-10) and the yarn bobbin is in spindle full. 5-00=4, Velocity Tracking: The machine operates with the Extra-feeding velocity directly proportional to the winding velocity and the proportional coefficient is determined by the Function Code 5-13.
Page 35
Yatai Inverter YTB-S-LT User’s Manual 5-03Extra-feeding Acceleration Setting Range: 0.1~300.0 S Factory Value:3.0 Time 5-04Extra-feeding Deceleration Setting Range: 0.1~300.0 S Factory Value:3.0 Time For the purpose of synchronous operation of the Extra-feeding and the Winding,please debug on-site the acceleration and deceleration time of the Extra-feeding motor to make both of them synchronous reliably. Because...
Page 36
Yatai Inverter YTB-S-LT User’s Manual broken. 5-07=1: After yarn broken, the Extra-feeding motor stops its operation in the mode of fast machine halt. It is applicable to the situation with the requirement to stop the Extra-feeding motor rapidly. 5-07=2: After yarn broken, the Extra-feeding motor stops its operation in the mode of fast machine halt with braking;...
Page 37
Yatai Inverter YTB-S-LT User’s Manual increasing frequency. It is commonly applicable to the situation of smaller textile yarn bobbin and then able to increase the spinning velocity in the allowable range of the extra-feeding velocity. As an example, if the setting length is 1000 m, 5-09=50Hz and 5-10=60Hz, then while the winding length increases from 0m to 1000m the operating frequency of the extra-feeding increases from 5-09 to 5-10.
Page 38
Yatai Inverter YTB-S-LT User’s Manual When the 5-00=4, this parameter is valid. The operating velocity of the extra-feeding motor is proportional to the velocity of the winding motor, so for various yarn the user should set the different and appropriate proportional coefficient to meet the sufficient extra-feeding amount.
Page 39
Yatai Inverter YTB-S-LT User’s Manual The Matching Table for the operation of the Winding and Extra-feeding Motors: The Operating Mode of the Winding Motor The Operating Mode of the Extra-feeding Motor Without 5-00=0 Extra-feeding Motor Constant Velocity 5-00=1 Frequency Decrease 0-06=0...
Yatai Inverter YTB-S-LT User’s Manual 6. Debugging and Application Before the products manufactured by our company are delivered out from factory, all have inspected comprehensively. However the process of loading, discharging and transportation, all may bring harmful effect to the products. For that reason, after you get the products, you should test them all-round in accordance with the following specific steps firstly: 6.1 Debugging Operating...
Yatai Inverter YTB-S-LT User’s Manual 6.2 Normal Operating 1. According to the site specific requirements, connect the pulse sensor for counting the length of yarn and the sensor for yarn broken. 2. In accordance with the spinning requirement, other parameters can be set up.
Yatai Inverter YTB-S-LT User’s Manual 7. Recovery Processing and Routine Maintenance In the actual use of the converter, due to be reflected by environment and working condition, it is possible to take place some error protection and abnormal phenomena. This chapter has given the processing method of some common faults.
Yatai Inverter YTB-S-LT User’s Manual External Storage Err4 Breakdown System Over Temperature Yarn broken □ * Yarn has Broken *Inspect whether or not the * Damage of the yarn probing device yarn is broken *Inspect whether or not the Yarn...
Yatai Inverter YTB-S-LT User’s Manual Decrease the variation of the load; Whether or not the variation of Increase capability the load is over? converter. Notice: If above treatments are invalid, please contact our factory to resolve it, don’t dismantle and repair by yourself.
Page 45
Yatai Inverter YTB-S-LT User’s Manual Advising to the Clients Thank you for your choice of our product. In order to ensure you can get the best after-sales service from our company, please read the following terms and do good jobs of related issues as below: Product Inspection at Out of the Box 1 To confirm whether or not the product is damaged during transport.
Page 46
Yatai Inverter YTB-S-LT User’s Manual Shanghai Yatai Instrumentation Corporation Company Headquarters: 8th Floor, Rong-Xin Building, 1851, Sichuan Road (North), Shanghai, China : , : Phone 021-51053128 51053913 021-51053123 : Postal Code 200081 : 128 Zhen-Yuan Road, Production Base Baoshan City Industrial Park, Shanghai, China :...