Page 1
USER MANUAL : CDS549 STRATUS PULSE LOGGER CDS549 Stratus Pulse Logger User Manual Document Number: CDS549 Stratus Pulse Logger User Manual Client: User Date: 1 December 2020 Issue: V1.0 Status: Draft Classification: Confidential S/W File Name CDS549 Stratus Pulse Logger User Manual.docx Copyright Cape Digital Solutions.
Page 2
USER MANUAL : CDS549 STRATUS PULSE LOGGER AMENDMENT HISTORY Issue Date Amendment Details Amended By 1 9 January 2021 Compile document Alex Romanov DOCUMENT NAME CLASSIFICATION DATE PAGE CDS549 STRATUS PULSE LOGGER USER CONFIDENTIAL 21-JAN-21 2 OF 26 MANUAL...
The Stratus Pulse Logger has been designed to allow for easy installation and setup without the need for a complicated server infrastructure. Setup and management software (CloudWorks) is also supplied free of charge to allow clients to manage their own networks and data. There are no monthly charges for collecting and hosting data as the client can provide this service themselves.
USER MANUAL : CDS549 STRATUS PULSE LOGGER Large onboard non-volatile memory - This logger can record in excess of 14400 datalog records (application dependent). Logging intervals from 1 minute to 1 month. Information is internally logged, time and date stamped and transmitted at programmable intervals.
USER MANUAL : CDS549 STRATUS PULSE LOGGER Architecture 3G GSM Bluetooth Interface Interface Non volatile Central Input 2 x Pulse memory Processor Interface Inputs ECO Interface Power Management External 12V 3 x Alkaline Power Supply Batteries Power Modes The Stratus Pulse Logger can operate in one of two power configurations.
USER MANUAL : CDS549 STRATUS PULSE LOGGER LED and button functions On the front of the logger, there are 2 LED's and a touch sensitive 'SELECT' button. Internally on the reverse side of the lid is the Bluetooth reset button.
USER MANUAL : CDS549 STRATUS PULSE LOGGER In order to reset the Bluetooth interface, with the housing open, please follow the below procedure. Remove all power from the logger - remember to remove the batteries if external power is present.
1.8 External Power Supply / Solar System Connection The CDS549 Stratus Pulse logger can be powered entirely from an external 12V (8-15V) 2A power supply or solar power source. Using a solar power source and also populating the logger with alkaline batteries means that the logger can be put into dual mode.
USER MANUAL : CDS549 STRATUS PULSE LOGGER Example configuration of water meter with electronic interface. Please note the polarity of the interface. Ground connection to pin 4 (or 6 for Input 2). 1.10 Using the ECO interface The onboard ECO interface is primarily used to support the GWF range of water meters with these interfaces installed.
USER MANUAL : CDS549 STRATUS PULSE LOGGER 1.11 Sim card and battery installation The CDS549 Stratus logger uses a MicroSIM and is installed as follows. 1. Slide the cover plate backwards to unlock. 2. Flip the cover plate up to expose the connections.
1.12 Installation considerations The CDS549 Stratus Pulse logger is environmentally rated to IP68 - max1.2m. In order to achieve this, it is critical that any cables entering the logger are properly sealed by the IP68 gland. This gland is designed to only have one cable exiting the logger and not multiple ones.
2.1 Setup via Bluetooth Configure The CDS549 Stratus Pulse logger has an onboard Bluetooth interface which allows for the device configuration to be done locally. There are two different places in the software to activate the Bluetooth connection. The first option is from the log in screen at start up.
Page 14
USER MANUAL : CDS549 STRATUS PULSE LOGGER The second option is on the Zone screen by pressing the 'Device Setup' button. Activating this function will launch the Bluetooth Server which will search for the available remote devices in the immediate vicinity.
Page 15
Once the Bluetooth connection has been established, Cloudworks will automatically activate the correct configuration screen needed for each device type. This device will immediately be placed into Command Mode and the current setup data retrieved and displayed on the right hand screen.
Page 16
USER MANUAL : CDS549 STRATUS PULSE LOGGER To switch between the Diagnostic Mode and Command Mode, simply press the 'Command/Connect' button. Switching from the Diagnostic Mode to Command Mode can take several seconds depending on what the logger is currently executing.
Page 17
USER MANUAL : CDS549 STRATUS PULSE LOGGER Local IP Local IP address assigned by the GSM network. This data is important when using a static IP system to ensure that the correct IP has been assigned to the logger. Datalog Size Number of records in the datalog/maximum number possible for the selected application type.
Page 18
Cloudworks loggers support the use of simcard pin codes. How this works is - should a simcard have a pincode activated, it will request the pincode when the modem powers up and starts connecting to the network.
Page 19
USER MANUAL : CDS549 STRATUS PULSE LOGGER If you are using a foreign simcard on a network, the logger will need to be told that it is allowed to use data roaming. Without that, the logger will shutdown communications if it detects a roaming data connection. This can be done by ticking the option box.
Page 20
USER MANUAL : CDS549 STRATUS PULSE LOGGER Battery operated loggers will wake up, connect to the server and upload their data. Should this fail, it would be a large drain on the battery of the logger to continually try and connect. For this reason, the logger has a single chance to wake up and establish a connection.
Page 21
Upgrading firmware on the logger can be done through the Bluetooth interface. Newer versions of the software for each type of device is embedded into the Cloudworks software so will not need an internet connection to collect the data. When in Command Mode, press the 'Upgrade Firmware' button. The first thing the software will do is to determine the current firmware version on the logger and see if there is an upgrade available.
Page 22
USER MANUAL : CDS549 STRATUS PULSE LOGGER Please do not at any stage interrupt the process while the firmware is downloading as this may leave the logger inoperable and necessitate that it get sent back to the manufacturer for recovery.
2.2 CDS549 Stratus Pulse Logger Setup via Remote Configure Once the remote connection has been established, Cloudworks will automatically download the current setup data and display it on the screen. This data can be refreshed at any time by pressing the 'Refresh' button in the top menu.
Page 24
- and pressing ENTER. The logger will then send an SMS to that number. The message should read, 'Hello from Stratus Pulse Logger CDS549 - Device Code xxxxxxxxxx'. The receiving number can then be used to send sms commands to that logger.
USER MANUAL : CDS549 STRATUS PULSE LOGGER 2.3 CDS549 Stratus Pulse Logger Setup via Offline Script Configure Once activated, the correct blank Scripting Editor screen will be displayed, ready for the capture of the settings that need to be altered.
Page 26
USER MANUAL : CDS549 STRATUS PULSE LOGGER Pending commands are those that still need to be executed. Listed also is the response to each command for diagnostic purposes. You can read back the current script to determine its status at any point by pressing the 'Read Script' button.