System Configuration ............7 Health and Safety ............. 8 Maintenance frequency ..........10 Maintenance Procedure ..........11 General Cleaning ............12 Cartridge Recycling and Replacement .....13 Standard Drawings ............14 Site Exit & Clean Up ............16 SPEL Stormwater Installation & Operation Manual | SPEL Filter...
The filters can be housed in either a concrete or the SPELFilter product fibreglass structure that evenly distributes the flow between cartridges. Figure 1 - SPELFilters in a concrete chamber / vault visit www.spel.com.au for detailed data sheets on our products...
Page 5
SPELFilter from sediment buildup. It is for this reason that SPEL recommended the sediment buildup not exceed 150mm above the vault floor, so as to avoid blocking the inlet ports of the SPELFilter.
Sizes SPEL Stormwater manufactures two height cartridges for varying site constraints as shown below. Each cartridge is designed to treat stormwater at a flow rate of 1.47 Litres per second and 2.83 Litres per second for the half- height cartridge (model No. SF.15-EMC-M) and full-height cartridge (model No. SF.30-EMC-M) respectively.
D. Traffic Control • Ensure responsibility is accepted by all employees to practice and promote a safe and healthy work It is not uncommon for SPEL Filter cartridges to be environment. installed underneath trafficable areas. Minimum traffic control measures will need to be put in place in accordance with traffic control plans set out by B.
• Unforeseen environmental hazards affecting the SPELFilter functionality. • Accumulation of debris/pollutants on the outlet chamber of the SPELFilter vault; • After large storm events, tidal or flooding impacts at the request of the owner; SPEL Stormwater Installation & Operation Manual | SPEL Filter...
SPEL representative. Assemble and position the gantry above the manhole safely and as practically as possible. Attach the winch or chain block to the gantry for lifting the SPEL Filters. Perform safety procedures ie. Attach harnesses etc. (if confined space).
Attach the winch 8. Reinstate SPELFilter system and disposal. or chain block to the gantry for lifting the SPEL Filters. At the completion of the site inspection, ensure the site Perform safety procedures ie. Attach harnesses etc. (if is reinstated back to its initial state and all pollutants confined space).
Attach the winch or chain block to the gantry for lifting the SPEL Filters. Perform safety procedures ie. Attach harnesses etc. (if 8. Install pipework and SPEL Filters.
Site Exit & Clean Up At the end of the scheduled maintenance, approved contractors or SPEL maintenance crew are required to reinstate the site to pre-existing conditions. Steps included but limited to are: • Ensure all access covers are securely inserted back into their frames;...