DANHYDRA K.I.S - PFU-KIS Operating Manual page 5

Portable filling unit

Advertisement

Operating manual
Portable filling Unit Model K.I.S - PFU-KIS
OPERATING GUIDE
Remove the dust cap (1), then fit the adapter on cartridge and place it
over the Inlet (1).
Connect power chord to power supply (2). Turn On / Off Switch to ON
(3). Switch between Manual or automatic mode by pressing the SET
button (6).
Before connecting a hose to the outlet
(8)
remember to open Flush
valve
(9)
while pumping in manual mode to flush machine for old
Grease if needed.
If automatic mode is enabled, turn SET Button
(6)
up or down to enter
desired volume to be Pumped.
Press START button
(5)
to begin pumping. START button
(5)
will turn
red when PFU KIS is pumping.
Turn the Flow Adjustment button
(4)
under operation to increase or
decrease flow.
KIS Display
(7)
will show the desired volume and progress if in auto-
matic mode.
In Automatic mode the PFU KIS will stop by itself when entered vol-
ume has been pumped.
NB!
If in manual mode the PFU KIS must be stopped by pressing STOP /
START button (5).
The STOP / START button
(5)
will turn green when the PFU KIS is
stopped.