DIGITAL PROCESS METER DMP 11 with accessories for analogue signals measuring • 230 VAC or 24 V AC/DC power supply • 6 digits LED 14,2mm display • Scale -/+ 60 000 • Isolated analogue output (active and passive) •...
Page 2
3. M AINTANANCE DMP 11 is constructed to require minimal maintainance. Front panel with foil keypad isn’t resistant to organic solvents (e.g. toluene, acetone etc...). Use only suitable non-agresive cleaners for cleaning front panel (e.g. industrial alcohol). To prevent long-term failure-free operation, is recommned to use device in specified temperature range, not expose to extreme climatic condition, which have effect to longtime lifecycle of electronic components.
Page 3
How to control DMP 11 After power-on device shows measured value and device entered main display mode. In main display mode we could switch between several values by pressing key (see the following table). Number of available items in main display mode vary due to settings and configuration of device.
000.000 0000.00 00000.0 hotovo Address menu of DMP 11 The individual functions and settings of the device are accessible at so-called addresses for simplicity. After entering the correct password, we enter the address menu, each address has its own number...
Page 5
It is necessary to have a signal source representing the end point connected to [ 20.00 ] the input during settings Boleslavova 4, 709 00 Ostrava 9 tel / fax: +420 59 662 70 97 - 5 - email: mercos@mercos.cz Created: 14.8.2019 , version 1.100en...
***) External input is optional accessory, please check your device if it is available ( see device label ) ****) Filtration is not active for potenciometers (selection 3 and 7 on A_01) Boleslavova 4, 709 00 Ostrava 9 tel / fax: +420 59 662 70 97 - 8 - email: mercos@mercos.cz Created: 14.8.2019 , version 1.100en...
Page 9
0,200 to 11,000m ) 011.000 1. We set user input scale end point to and confirm it by Boleslavova 4, 709 00 Ostrava 9 tel / fax: +420 59 662 70 97 - 9 - email: mercos@mercos.cz Created: 14.8.2019 , version 1.100en...
Page 10
A_19 L2 limit display in main display mode offers direct access to L2 limit value settings. Boleslavova 4, 709 00 Ostrava 9 tel / fax: +420 59 662 70 97 - 10 - email: mercos@mercos.cz Created: 14.8.2019 , version 1.100en...
Page 11
Due to Limit L3 control settings (A_48) relay acts as described on address A_16. Boleslavova 4, 709 00 Ostrava 9 tel / fax: +420 59 662 70 97 - 11 - email: mercos@mercos.cz Created: 14.8.2019 , version 1.100en...
Page 12
The offset value is added to the measured value - the displayed data may be distorted! Boleslavova 4, 709 00 Ostrava 9 tel / fax: +420 59 662 70 97 - 12 - email: mercos@mercos.cz Created: 14.8.2019 , version 1.100en...
Page 13
Password can be set in range In case of password lost, follow instructions at section „address menu of DMP11“ Boleslavova 4, 709 00 Ostrava 9 tel / fax: +420 59 662 70 97 - 13 - email: mercos@mercos.cz Created: 14.8.2019 , version 1.100en...
Page 14
+ 0,7 W – isolated analogue output INTRODUCTION + 1,0 W / 3.0 W – excitation power supply Digital process meter DMP 11 provides physical value measuring with displaying it within -60000 to +60000 digits range. Internal analogue Exc. power supply...
Page 15
ORDER CODE TERMINAL STRIP DMP 11 - . . . Power supply is not universal – A B C D E please specify power supply in order code 1 – 24 VAC / VDC , -15 to +20 % RS 485...