Acela Truck DPMU20C Operator's Manual

Disaster portable morgue unit (containerized)

Advertisement

Quick Links

DISASTER PORTABLE
MORGUE UNIT
(CONTAINERIZED)
OPERATOR MANUAL
& STORAGE INSTRUCTIONS
THIS MANUAL IS APPLICABLE FOR MODEL
DPMU20C ONLY
Acela Truck Company
540 Business Hub Drive
Belgrade, MT 59714 USA
www.acelatruck.com
+1 (406) 581-9929
CAGE: 7WC08
Version 1.0, February 2020
Document Number 60

Advertisement

Table of Contents
loading

Summary of Contents for Acela Truck DPMU20C

  • Page 1 DISASTER PORTABLE MORGUE UNIT (CONTAINERIZED) OPERATOR MANUAL & STORAGE INSTRUCTIONS THIS MANUAL IS APPLICABLE FOR MODEL DPMU20C ONLY Acela Truck Company 540 Business Hub Drive Belgrade, MT 59714 USA www.acelatruck.com +1 (406) 581-9929 CAGE: 7WC08 Version 1.0, February 2020 Document Number 60...
  • Page 2 COPYRIGHT This manual is protected under copyright, 2020 by Acela Truck Company and may not be duplicated, in whole or in part, without the expressed written permission of Acela Truck Company. All rights reserved. This manual is printed in the United States of America.
  • Page 3 Introduction OVERVIEW OF OPERATION AND UNIT DESIGN The DPMU is designed to maintain 35°F interior temperature at 120°F outside temperatures while stationary. The unit is designed to run primarily on 240V 50A shore power. The DPMU is additionally equipped with a back-up generator to provide emergency and short-term power supply. A 240VAC 50A power service is required to operate the onboard refrigeration unit and battery charger.
  • Page 4 DPMU BASIC OPERATION TRANSPORT AND ENTRY DOORS The containerized DPMU is equipped with two (2) sets of doors; one (1) pair of transport doors that lock and seal the DPMU during travel and one (1) refrigerated entry door that is specially designed to seal the refrigerated compartment and maintain temperature.
  • Page 5: Shore Power

    LIGHTING The DPMU is equipped with internal and external 12VDC LED lighting. All lights are operated from a single switch panel located on the interior left wall. The switch panel is activated by turning the Master 12VDC Power Switch (located on the side of the power distribution box) to ON. All switches are backlit and are operated by depressing the switch desired.
  • Page 6: Generator Power

    GENERATOR POWER Ensure generator has fuel, fuel shut-off switch is in the ON position, main circuit breaker is in the ON position. Start generator according to instructions found in generator manual. NOTE: As a safety feature, the transfer switch will not transfer generator power for 20 to 45 seconds after startup. The green “240VAC POWER ON”...
  • Page 7: Refrigeration Unit

    USE CAN CAUSE ELECTRICUTION. ELECTRICAL MAINTENANCE SHOULD ONLY BE PERFORMED BY A LICENSED ELECTRICIAN REFRIGERATION UNIT The onboard refrigeration unit is controlled by a controller located in a waterproof box mounted to the side of the power distribution box. After 240VAC power is supplied to the DPMU, the refrigeration unit is turned on/off and temperature can be set on the controller located inside the power distribution box.
  • Page 8: Maintenance

    ENTRY RAMP A 1,500 lb. capacity entry ramp is stowed inside the container. After positioning the container and securing the transport doors, unfold the ramp with the flat, punched surface facing up. Secure the mounting tabs on the ramp into the mounting receivers on the DPMU rear wall, under the entry door. The ramp is designed to be left in place while deployed.
  • Page 9: Long Term Storage

    LONG TERM STORAGE When storing the DPMU for long periods of time:  Check all systems and interior/exterior lighting for proper performance  Thoroughly clean, disinfect all interior surfaces, accessories, parts, etc. – use flooring cleaners approved for vinyl flooring. ...
  • Page 10: Dimensions And Weight

    HIGH VOLTAGE! WARNING - Your Disaster Portable Morgue Unit utilizes high voltage power to operate. THE POWER DISTRIBUTION BOX COVER SHOULD BE CLOSED AND LATCHED AT ALL TIMES UNLESS REQUIRED TO CONTROL REFRIGERATION UNIT, PERFORM MAINTENANCE OR TROUBLESHOOTING. THE POWER DISTRIBUTION PANEL CONTAINS HIGH VOLTAGE. IMPROPER USE CAN CAUSE ELECTRICUTION.