Download Print this page

Advertisement

Quick Links

TURNING 'ON' Equipment - Plug 3 pin plug into a standard General Purpose Outlet (GPO): 230V – 240V / 50Hz / 1Phase
1.
1.1
Once plugged into the wall socket turn 'ON' the power switch on the GPO, the controller will 'beep' turn On, then turn Off and idle in
standby mode;
1.2
Press and hold in the 'Tick' ( ) or 'OK' symbol, or the 'Menu' key ( ) for 3-4 seconds or until the controller beeps and turns on.
(Display will display 'COOLING' after an initial systems/firmware check, and display the equipment ambient temperature)
TURNING 'OFF' Equipment - Do not 'Turn Off' the equipment by switching off the power at the wall or unplugging the power;
2.
2.1
Press the 'Menu' key ( ) and the display will automatically display 'TURN OFF m1' as the first menu option, Press the 'Tick' ( ) symbol
or 'OK' key TWICE to confirm;
(NOTE: if >>CONFIRMED<< does not display the defrost has not commenced, ensure >>CONFIRMED<< is displayed by pressing the 'Tick' ( ) symbol or 'OK' key
TWICE)
CHANGING 'SET TEMPERATURE'
3.
3.1
Press the 'Menu' ( ) key and using the arrow up symbol select 'CHANGE SET m2' Press the 'Tick' ( ) symbol or 'OK' key and the
Menu will display SETPOINT -02˚C (Refrigerated) or SETPOINT -18˚C (Freezers);
3.2
Using the arrow Up or Down (
TWICE to confirm;
3.3
The controller will display >>CONFIRMED<<
(NOTE: if >>CONFIRMED<< does not display the defrost has not commenced, ensure >>CONFIRMED<< is displayed by pressing the 'Tick' ( ) symbol or 'OK' key
TWICE)
CHANGING 'HUMIDITY' LEVEL
4.
4.1
Press the 'Menu' ( ) key and using the arrow 'Up' ( ) symbol select 'CHANGE rh% m3' Press the 'Tick' ( ) symbol or 'OK' key and
the Menu will display SET Rh% 90% (Refrigerated only);
4.2
Using the arrow 'Up or Down' (
TWICE to confirm;
4.3
The controller will display >>CONFIRMED<<
(NOTE: if >>CONFIRMED<< does not display the humidity level has not been changed, ensure >>CONFIRMED<< is displayed by pressing
the 'Tick' ( ) symbol or 'OK' key TWICE)
MANUAL DEFROST OPTION
5.
5.1
Press the 'Menu' ( ) key and using the arrow 'Up' ( ) symbol select 'DEFROST m4' to start a defrost cycle: Press the 'Tick' ( ) symbol
or 'OK' key TWICE to confirm;
5.2
The controller will display >>CONFIRMED<<
(NOTE: if >>CONFIRMED<< does not display the defrost has not commenced, ensure >>CONFIRMED<< is displayed by pressing the 'Tick' ( ) symbol or 'OK' key
TWICE)
DEEP FREEZER - (for continuous fast chill cycle or fast freeze cycle operation below the set point temperature value) –
6.
*** ATTENTION DO NOT USE AS A SUBSTITUTE FOR A PERMANENT FREEZER OR BLAST CHILLING & FREEZING ***
Important Notice: The inbuilt 'Deep Freezer' feature is not intended to be used for more than a Maximum period of 6hrs. This feature is only
recommended for use in order to bring down the temperature of goods stored within the counter quickly, or as a short-term 'freezer' solution.
6.1
Press the 'Menu' ( ) key and using the arrow up symbol select 'DEEP FREEZE m5' to convert a 'refrigeration' cycle to 'Deep Freezer'
cycle:
6.2
Press the 'Tick' ( ) symbol and the controller will display 'COOLING h00:00', select the period of time using the arrow 'Up' ( ) symbol
increasing the 'Deep Freezer' cycle in 15min increments (min period of 15mins, up to maximum period 06:00hrs): Press the 'Tick' ( )
symbol or 'OK' key TWICE to confirm;
6.3
The controller will display >>CONFIRMED<<
(NOTE: if >>CONFIRMED<< does not display the defrost has not commenced, ensure >>CONFIRMED<< is displayed by pressing the 'Tick' ( ) symbol or 'OK' key
TWICE)
Illustrated (Basic) HTWL Controller Functions – non-service type
) symbols select the desired temperature set point, to confirm Press the 'Tick' ( ) symbol or 'OK' key
) symbols select the desired level of humidity, to confirm Press the 'Tick' ( ) symbol or 'OK' key
IGLU COLD SYSTEMS PTY LTD © 2015
TEL. (02) 9119 2515 FAX. (02) 9913 8667
EMAIL. sales@iglucoldsystems.com.au
WEB. www.iglucoldsystems.com.au

Advertisement

loading

Summary of Contents for iglu HTWL

  • Page 1 EMAIL. sales@iglucoldsystems.com.au WEB. www.iglucoldsystems.com.au Illustrated (Basic) HTWL Controller Functions – non-service type TURNING ‘ON’ Equipment - Plug 3 pin plug into a standard General Purpose Outlet (GPO): 230V – 240V / 50Hz / 1Phase Once plugged into the wall socket turn ‘ON’ the power switch on the GPO, the controller will ‘beep’ turn On, then turn Off and idle in standby mode;...
  • Page 2 ONCE, and the controller will display either: ‘PASSWORD -> 00’; Using the arrow keys select the password number provided by IGLU Service Department and Press the ‘Tick’ ( ) symbol or ‘OK’ key ONCE, the service menu is now accessible.