Page 5
EU DECLARATION OF CONFORMITY Manufacturer’s Name: Lighthouse Worldwide Solutions, Inc. Manufacturer’s Address: Lighthouse Worldwide Solutions, Inc. 1221 Disk Drive Medford, OR 97501 USA Declares that the product: Product Name: Biological Air Sampler Model Number(s): REMOTE ActiveCount System Conforms to the following Product Specifications:...
Page 8
Access RAC Information ....................4-2 Appendix A Limited Warranty Limitation Of Warranties: ..............A-1 Warranty Of Repairs After Initial Two (2) Year Warranty: ....A-1 Appendix B Remote ActiveCount MODBUS Register Map v1.49 COMM Settings ......................B-1 Supported MODBUS Commands .................. B-1 Sensor Settings Registers ...................
Hexadecimal numbers are shown with the word "hex"or with a small "h" following the digits. For example: hex 0D Additional For more information about the Lighthouse REMOTE ActiveCount System, contact Lighthouse Worldwide Solutions. Help Service and Support Tel: 1-800-945-5905 (USA Toll Free) Tel: 1-541-770-5905 (Outside of USA) techsupport@golighthouse.com...
General Safety Safety Warnings and cautions are used throughout this manual. Familiarize yourself with the meaning of a warning before operating the particle Considerations sensor. All warnings will appear in the left margin of the page next to the subject or step to which it applies. Take extreme care when doing any procedures preceded by or containing a warning.
RAC System, RAC Controller or instrument. For simplicity, these terms are interchangeable and mean the same thing. Description The REMOTE ActiveCount is an active air sampling device that employs the impaction principle to impact particles bearing microbiological material onto a plate or petri dish loaded with nutrient agar.
Lighthouse REMOTE ActiveCount Installation Guide The Impactor (bottom mount or table mount) is installed at the sampling location using the tubing connected to the Impactor port. Figure 2-2 Impactors REMOTE Table 2-1 REMOTE ActiveCount Specifications ActiveCount Specifications Vacuum Requirement 16inHg Flow Rate 1.0CFM (28.3 LPM)
Verify the contents of the package against the shipping list. If anything appears to be missing, please contact your sales representative at Lighthouse Worldwide Solutions immediately at 510-438-0500. To maintain your warranty, keep the undamaged shipping container and all packing material for reshipment of the instrument for servicing or repair.
Lighthouse REMOTE ActiveCount Installation Guide Shipping Should it become necessary to return the unit to the factory for any reason, contact Lighthouse Customer Service or visit our website, Instructions www.golighthouse.com/rma, and obtain a Return Merchandise Authorization (RMA) number. Reference this number on all shipping documentation and purchase orders.
Getting Started Installation The RAC Controller and the Remote Switch can be mounted to a facility wall or customer equipment to allow sampling of critical locations. Mounting the controller to a wall will allow Grade A environments to be sampled directly and will allow the remote use of impactors and isokinetic probes.
Page 18
Lighthouse REMOTE ActiveCount Installation Guide 3. Once the controller and switch are mounted, install the tubing to the impactor and vacuum ports on the bottom of the controller. See Figure 3-2. Figure 3-2 Controller Ports 4. Attach two Cat-5 Communication cables to the RJ-45 ports labeled "RS-232"...
Getting Started DIP Switch DIP Switch General Definitions Settings Table 3-1 provides the DIP switch settings for each position, including their descriptions. Each switch can be set in the following positions: OFF (UP) = 0, ON (DOWN) = 1 Note: Use a tool with a very small pointed tip to change DIP Switch...
Getting Started RAC Controller RJ-45 Pinouts The "RS232" port on the Controller has RJ-45 pinouts shown in Table 3-3. Table 3-3 RS232 Port- RJ-45 Pinouts RJ-45 Pin Signal Name RS-232 TX RS-232 RX RESERVED for future use RS-485B RS-485A RESERVED for future use RESERVED for future use Note: The Controller "Switch"...
Lighthouse REMOTE ActiveCount Installation Guide Remote Switch RJ-45 Pinouts Table 3-5 displays the terminal block pinouts for the Remote Switch. Table 3-5 Switch Connector - Terminal Block Pinouts Signal Name 24V IN TX OUT RX IN Attach the Cat-5 Communication cable from the Controller Switch connector to the terminal block in the Remote Switch as shown in Figure 3-4.
Getting Started Note: When the switch is wired correctly, the Power and Flow lights will The cable going to the Remote Switch must illuminate as shown in Figure 3-6. be connected to the recepticle inside the switch. The Lighthouse Installation Team will ensure that the switch is properly wired before the RAC System is activated.
Page 24
Lighthouse REMOTE ActiveCount Installation Guide Choose "Data Collection" on the LMS Express home page under the heading Other Options. On the Data Collection page, choose "Real- Time Data Collection". See Figure 3-8. Figure 3-8 Data Collection & Real-Time Data Collection Select Add Network Connection in the Connection Task Panel and enter the IP address.
Page 25
Getting Started In the Setup Instrument Driver dialog box, confirm that the Instrument Enable checkbox is active. Select an instrument location for the Instrument Location, leave the Instrument Address at 1 and select the LWS Remote Active Count from the Instrument Type drop- down menu.
Lighthouse REMOTE ActiveCount Installation Guide Figure 3-12 RAC System in Cycle After one complete cycle, the instrument is now configured and can be controlled through LMS Express RT or by the Remote Switch. Remote Switch Operation The Remote Switch operates the Controller after the unit has been configured by LMS Express.
Getting Started • Pressing the Remote Switch once starts the Remote ActiveCount. The Sampling light will illuminate. • Pressing the switch a second time pauses the operation. • Pressing the switch a third time will resume the sample. Holding the button for 3-5 seconds at any part of the process will stop the sample.
Page 28
Lighthouse REMOTE ActiveCount Installation Guide 6. Confirm that the Remote Switch is connected to the Switch Port and that the Power and LED is on. See Figure 3-15. Figure 3-15 Remote Switch with Power 7. Press and hold the Start/Stop button on the Remote Switch while applying power.
Sample time must be calculated for the specific sample volume Protocol desired based on 1CFM flow. Sample time calculations are performed and written to the Remote ActiveCount by LMS Express. Samples with multiple cycles must have the individual sample time calculated for each sample.
Lighthouse REMOTE ActiveCount Installation Guide Operating the The Remote ActiveCount can be operated by using the MODBUS Protocol. The applicable action commands are listed in Table 4-2. RAC System Table 4-2 Action Commands Value Register Action 40002 Saves all writable 40002 register values to the EEPROM.
STRICT LIABILITY, OR PRODUCT LIABILITY CLAIM AND BUYER AGREES TO WAIVE SUCH CLAIMS. LWS’s SOLE AND EXCLUSIVE LIABILITY AND BUYERS SOLE Lighthouse Worldwide Solutions (LWS) warrants that all AND EXCLUSIVE REMEDY, FOR ANY equipment shall be free from defects in material and...
Remote ActiveCount MODBUS Register Map v1.49 COMM Lighthouse instruments using MODBUS require the following communications settings as shown in Table B-1. Settings Table B-1 MODBUS Communications Settings Baud Rate 19200 Data Bits Stop Bits Parity None Hardware Protocol RS485, USB and Ethernet...
Lighthouse REMOTE ActiveCount Installation Guide Register Map Sensor Settings Registers Instrument settings are stored in holding registers (the 4xxxx series), which are mostly read/writable. Not all holding registers are writable. Table B-3 describes the contents of these registers. Table B-3 Sensor Settings Registers...
Page 35
Remote ActiveCount MODBUS Register Map v1.49 Table B-3 Sensor Settings Registers Register Data Type Description 40020 ASCII string Model Name char[10], char [11] 40021 ASCII string Model Name char[12], char [13] 40022 ASCII string Model Name char[14], char [15] 40023 unsigned integer Flow Rate.
Page 36
Lighthouse REMOTE ActiveCount Installation Guide Table B-3 Sensor Settings Registers Register Data Type Description 40037 unsigned integer Alarm Mode. Type of alarming performed 40038 unsigned integer Alarm Parameter. Control parameter for given alarm mode. 40039 unsigned integer Laser Reference Voltage (millivolts)
Page 37
Remote ActiveCount MODBUS Register Map v1.49 Alarm Mode (40037) defines the type of calculation performed to define an alarm condition. Alarm Mode = 0 corresponds to conventional threshold alarming; channel bit set if threshold exceeded for that given channel. Alarm Parameter (40038) defines additional parameters that may be needed in defining an alarm mode.
Lighthouse REMOTE ActiveCount Installation Guide Device Status The Device Status register (40003) displays the current status of the device. Table B-6 Device Status Description RUNNING: Set when a start command is executed remotely via Command 9 (manual start) or Command 11 (instrument start) or through the user interface.
Page 39
Remote ActiveCount MODBUS Register Map v1.49 Table B-7 Command Register Value Action Enable Local Control. Unlocks the instrument’s user interface. Instrument changes can be made at the device itself or through MODBUS. Start local pump, if applicable - perform before 9 below.
Lighthouse REMOTE ActiveCount Installation Guide Data Data is stored in the input registers (30xxx series), which are read-only. All data items are four bytes long and are stored across two registers. Registers Byte and word order for integer data is big-endian. Thus, data items are formed by placing the high bytes in front of the low bytes.
Lighthouse REMOTE ActiveCount Installation Guide Data Status Byte (30007 - 30008) Note: The registers used for the Data Status Byte are 30007 and 30008. Although MODBUS sends 4 bytes of status information, The bit order of the Data Status Byte is 7 to 0, where bit 7 is the most Lighthouse instruments significant bit and bit 0 is the least significant bit.
Remote ActiveCount MODBUS Register Map v1.49 Alarm Flags in Channels (30076) Register 30076 represents the flag bits corresponding to particle channels that have exceeded the threshold [Threshold High Registers (45xxx series)] based on alarm mode. Data Type Registers Note: The 41xxx register series is used to identify the type of data items in the...
Lighthouse REMOTE ActiveCount Installation Guide Note: Particle data items are entered as shown in Table B-11. They contain Only Particle data types have numbers in numbers, sometimes a space and sometimes a period used as a decimal their strings. point. These entries are used to identify particle channel sizes and are always expressed in microns.
Remote ActiveCount MODBUS Register Map v1.49 Table B-12 Data Units Units Description Units Description Meters ft^2 Square feet mBar Milli-bar Square meters Volts ft^3 Cubic feet Milli-volts Cubic meters Amperes Liters Milli-amps Cubic feet per minute Ohms Cubic meters per minute...
Page 46
Lighthouse REMOTE ActiveCount Installation Guide These registers run in parallel with the data registers (30xxx series). For example, data register 30010’s enable register would be 43010. Data register 30016’s enable register would be 43016. Note: The user can enable multiple particle channels for alarming at the same...
Remote ActiveCount MODBUS Register Map v1.49 Table B-14 Alarm Enable Registers Register Data Type Description 43045 unsigned int Enable for Analog Channel 3 [high] 43046 unsigned int Enable for Analog Channel 3 [low] 43047 unsigned int Enable for Analog Channel 4 [high]...
Lighthouse REMOTE ActiveCount Installation Guide Threshold Setup Registers Threshold data is stored in the input registers in the 45xxx series which are read/write. All threshold data items are 4 bytes long and are stored across 2 registers. Byte and word ordering is big-endian. Thus, data items are formed by placing the high bytes in front of the low bytes.
Remote ActiveCount MODBUS Register Map v1.49 Table B-16 Alarm Threshold Registers Register Data Type Description 45023 unsigned int Threshold for Particle Channel 8 [high] 45024 unsigned int Threshold for Particle Channel 8 [low] Setting the Alarm Threshold Value The Alarm Threshold Value is set in the low register of the channels.