Advertisement

Quick Links

NEBULISER
NEBULISER
COMPLETE NEBULISER KIT
(ADULT & PEDIATRIC MASK WITH MOUTHPIECE)
Compact
Lightweight
Family Friendly
Instruction Manual
Model No: ECO-NEB01
oklet_REV_042020.indd 3
2020/04/06 11:4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECO-NEB01 and is the answer not in the manual?

Questions and answers

Summary of Contents for econocare ECO-NEB01

  • Page 1 NEBULISER NEBULISER COMPLETE NEBULISER KIT (ADULT & PEDIATRIC MASK WITH MOUTHPIECE) Compact Lightweight Family Friendly Instruction Manual Model No: ECO-NEB01 oklet_REV_042020.indd 3 2020/04/06 11:4...
  • Page 2: Table Of Contents

    Table of Contents Introduction ..............3 Specifications ..............3 Description ..............4 Accessories ..............4 Operation Instruction ........... 5 Cleaning ................ 5 Maintenance ..............6 Warranty............... 6 IEC Symbols ..............6 Important Safeguards ........... 6 Technical data ............... 8 EMC ................9 Troubleshooting ............
  • Page 3: Introduction

    Intended use: The Econocare Nebuliser is designed to deliver the prescribed medicated solution to assist patients with the treatment of respiratory disorders such as asthma, allergies and bronchitis. Nebulising converts the medicated solution into an aerosolized mist which is inhaled by the patient through the mouthpiece or mask.
  • Page 4: Description

    Description: 1. Air outlet connector 4. Power cord 7. Air inlet connector 2. Filter cap 5. T-mouthpiece 8. Tubing 3. Power switch 6. Nebuliser cup 9. Foam filters Power switch Air Outlet Connector Air Openings Nebuliser Cup Holder Filter & Cover Accessories: Nebuliser machine Air tube...
  • Page 5: Operation Instruction

    Operating Instructions: 1. Place the Econocare Nebuliser on a stable, sturdy and flat surface so that the unit can be easily reached when you are seated. 2. Pull the power cord out from the base of the unit, and make sure that the unit is in the “off”...
  • Page 6: Maintenance

    Do NOT operate without a filter. Warranty: We warrant the Econocare nebuliser to be free from defective workmanship and materials for a period of (1) year from the date of purchase. Check with your retailer for more details.
  • Page 7 Do not untwist the jet nebuliser during operation. Follow your medical practitioner’s instructions on type and dosage of medication required. Do not pour more than 6ml of solution into the jet nebuliser. DANGER: TO REDUCE THE RISK OF ELECTROCUTION. Always unplug the unit immediately after using. Do not use while bathing.
  • Page 8: Technical Data

    Aerosol Output: **0.33 ml (2ml,1%NaF) Aerosol Output Rate: **0.06ml/min (2ml,1%NaF) Econocare nebuliser the particle size distribution curve as well: Result of cascade impactor **measurements for particle size with Econocare nebuliser and nebuliser kits MMAD = Mass Median Aerodynamic Diameter oklet_REV_042020.indd 10...
  • Page 9: Emc

    Important information regarding Electro Magnetic Compatibility (EMC) The Econocare Nebuliser needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided. This unit can be affected by portable and mobile RF communications equipment.
  • Page 10 Guidance and manufacture’s declaration – electromagnetic immunity This is intended for use in the electromagnetic environment specified below. The user should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Electrostatic dis- ±6 kV contact ±6 kV contact...
  • Page 11 Guidance and manufacture’s declaration – electromagnetic immunity This is intended for use in the electromagnetic environment specified below. The user should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Portable and mobile RF communications equipment should...
  • Page 12 Trou Chec Recommended separation distances between portable and mobile RF communications equipment and the nebuliser. This is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the nebuliser as recommended below, according to the maximum output power of the communications equipment.
  • Page 13: Troubleshooting

    Note: If the suggested remedy does not solve the problem, do not try to repair the device. No parts of the unit are user serviceable. Return the unit to an authorized Econocare retail outlet or distributor. oklet_REV_042020.indd 15...
  • Page 14: Disposal

    Disposal: Correct Disposal of this product (Waste Electrical & Electronic Equipment) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.