BYSKEUGNEN Lilla Installation And Operating Instructions Manual

BYSKEUGNEN Lilla Installation And Operating Instructions Manual

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for BYSKEUGNEN Lilla

  • Page 2 Flue gas temperature (at nominal heat output): 187 Flue pipe dimension: Ø150 mm inside Floor Byskeugnen must be placed on a noncombustible floor. Only place the stove on floors with sufficient carrying capacity, weight of the chimney included. If not, a load distribution plate can be used.
  • Page 3 European standards, must be observed when using this product. Before the use of your Byskeugnen stove, the installation must be inspected by a qualified inspector. Any modifications to the stove may result in the product and safety features do not function as intended.
  • Page 4 First use When the stove is used for the first time some smell from the paint can occur. The room should be thoroughly ventilated during this first use. Closed Open Daily use - wood burning Start up Bypass damper 1 Open the bypass damper. (to improve the draft from the beginning) 2 Open the control for primary air, the control for secondary air and the two controls for startup air on the door.
  • Page 5 IMPORTANT Your stove can be very hot. Use the cold hand device to open the door and to adjust the controls. When you open the door during fire, always open the bypass damper first to avoid smoke coming in to the room. Never throw the logs in to the fireplace, the ceramics can crack.
  • Page 6 Troubleshooting Poor draft - If you have a damper mounted in the flue pipe or in the brick chimney, make sure it is open. - If you have an inlet air vent in to the room, make sure it is open. - Foggy and rainy weather can have a big impact on the chimney draft and it might be necessary to use other air control settings to ensure good performance.