Installation Guide; Locate The Mineral Mizer - O-SO Pure Mineral Mizer Installation, Operation & Service Manual

Deionized water system
Table of Contents

Advertisement

System Flushing: The reverse osmosis (RO) membrane and the post-polishing filter in this system both contain
materials to prevent microbiological growth and freezing. If ingested, these may cause irritation of the
gastrointestinal tract, colic, diarrhea or other symptoms and is also unfit for use as autoclave water. The first 5
gallons of water produced by a RO membrane and the post-polishing filter must be discarded (flushing of both
components occurs simultaneously). Follow the instructions in this manual to ensure this flushing takes place.
Feed Water Quality: This RO system should not be used for treatment of water that is microbiologically unsafe or
of unknown quality. Unsafe water can cause proliferation of bacteria within the Mineral Mizer, which can lead to
the water being unsafe to handle. If the feed water quality is unknown, have a sample of the water tested by a
qualified laboratory or agency and implement the necessary measures to ensure a safe water supply.

Installation Guide

Locate the Mineral Mizer

1. Mount the back panel of the Mineral Mizer head on a wall that will provide access to change the
filters. If cabinet mounting, mount the Mineral Mizer so that the right side is closest to the front.
Locate the mounting screws using the system-mounting TEMPLATE provided or simply mark and
drill three mounting holes 6.5" apart along a horizontal line at least 18" above the floor. A-dec
MSMD cabinets produced after April 22, 2011 have Mineral Mizer mounting hardware pre-
installed at the factory.
2. If the Mineral Mizer will be moved to make routine service easier, move it to that location now.
For example, if it is to be mounted inside a cabinet, the service location may be on the floor
directly in front of that cabinet.
3. Place the water Tank within 10 feet of the
Mineral Mizer. For a cabinet install, place
the Tank in the back of the cabinet with its
valve facing the wall where the Mineral
Mizer will be mounted.
Install plumbing modifications
4. Turn OFF the cold water supply.
5. Angle Stop Valve - Remove the Angle Stop
Valve from the installation kit. Beneath the
sink, disconnect the faucet's cold water tube
from its associated stub plumbing. Install
the Angle Stop Valve on the cold water stub plumbing. Reconnect the faucet's cold water tube to
the top of the Angle Stop Valve. Close the Angle Stop Valve and turn on the cold water supply,
checking for leaks.
6. Install the chrome and red faucets- I
options include the sink pop-out or through the countertop overhanging the sink.
Question or comments? Contact O-SO Pure at (800) OSO-PURE or support@osopure.com.
IMPORTANT WARNING - PLEASE READ
nstall the chrome & red faucets per its included instructions. Location
Copyright
2016 O-SO Pure. All rights reserved.
©
Page 6 of 16
Mineral Mizer Owner's Manual (rev. 7)
Drain Saddle (installed)
NOTE: Some state or local codes may require that the
drain saddle be served by a trap other than the one
serving the garbage disposal. Before installing, please
check with code authorities.
DWS-SADI

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dws-sadiDws-sadi-dDws-sadi-r

Table of Contents