Advertisement

Quick Links

Manual
®
µPhase
UNIVERSAL
Version 2.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the uPhase UNIVERSAL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trioptics uPhase UNIVERSAL

  • Page 1 Manual ® µPhase UNIVERSAL Version 2.0...
  • Page 2 Nevertheless, no responsibility for damages due to using this information or liability for errors or production losses are assume by TRIOTICS Berlin GmbH. All rights to alterations and further development based on technological advancements, as well as printing errors reserved. © 2020 TRIOPTICS Berlin GmbH, Germany...
  • Page 3 The documentation contains all necessary information needed to run the measurement system securely. NOTICE Read the manual carefully before working with the measurement system. Specially pay atten- tion to the safety instructions. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 4 Persons working with the measurement system had to be trained regularly about the danger handling the system. 1.4 Form of the Safety instructions Safety instructions are weighted differently indicated with different symbols and key words. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 5 Fig. 1-1: Structure of safety instructions Key word Indicates the seriousness of danger (see above). Type and source of danger Indicates danger is possible and for what reason it can arise. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 6 1.5.3 Operation with software The menus and buttons of the software are marked with a different font. Example: – Chose <Data> <Intensity> or press the key F10. The window Intensity opens. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 7 M. 1.5.4 Designation ® µPhase is a registered trademark of the TRIOPTICS group. Should a trademark not been expressly named, it doesn‘t allowed their unmarked use. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 8 Introduction ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 9 It is only allowed to use the µPhase UNIVERSAL for the topography measurements of reflective surfaces and wave- fronts of optical systems as well as radius and back-focal- length measurements. Another use is not intended. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 10 • Avoid damages of the connection cables and fiber. It is not permitted to pull the connector cables or the fiber. Secure the cables to avoid the risk of stumbling. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 11 (“Qualified person”, page 2). NOTICES Imprecise measurement results The handling of not adequate instructed persons can cause imprecise or incorrect measurement result or damages at the measurement system. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 12 Only use appropriate lifting tools, e.g. a fork lift. • If the system contains a radius measurement rail, it has to ensure that it is transported horizontally. • Never stand underneath heavy loads. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 13 Do not work, if one casing part is missing or damaged. Replace removed parts immediately and inform the producer or the responsible representa- tion (Register Contacts). ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 14 1 and can cause eye damage! – Never remove the fiber, if the laser is turned – Never look into the beam or his reflection, also not with optical instruments. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 15 – Information concerning the software and the right choices of configuration can be found in this documentation (Register Instruction manual) or in the direct help of the software. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 16 2.8 Position of safety note ® Interferometer µPhase ® Fig. 2-1: Safety note and type plate at the µPhase Laser Fig. 2-2: Safety note and type plate at the laser ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 17 • The operator must make ensure that the personnel work- ing on and with the measurement system had read and understand the operating manual and the safety instruc- tions. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 18 Safety instructions ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 19 Click on the µShape icon at the desktop to start the µSha- software. Choose an appropriate template and if necessary, change the used measurement lens. Fig. 1-1: Opened µShape screen ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 20 If the calibration was successfully finished, switch back into the measurement mode, again with a mouse click on the but- ton C so it changes to M. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 21 The measurement system now starts a measurement according the current measurement parameters and eval- uate the measurement according the current evaluation parameters. The measurement results are displayed as a topography picture afterwards. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 22 . After the program is closed the computer could be shut down. Switch off additional devices. At last turn off the laser and put back on the protection cap on the measure- ment lens. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 23: Table Of Contents

    Save/load/export of measurement results..............43 Printing measurement results ................... 45 3.10 Shortcuts ........................47 3.11 Shut down the measurement system................ 48 Options ..................51 µShape Addon-Module ..................51 ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 24 ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 25: System And Functions

    Computer and power supply connector (USB 3 for µPhase Adapter for fiber connection ® Setting wheel for the filter (only for the µPhase 3.3) to change the reflectivity ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 26 Fig. 1-3: µPhase UNIVERSAL without radius measurement rail ® ® µPhase ‐mount (to mount the lens and the µPhase ® lens with µPhase interferometer sample holder (incl. tilt and x-y-table) ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 27 – Only use the delivered screws. CAUTION! Do not touch the encoder band. It can cause damage to the distance measurement system. encoder band ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 28: Operating Elements

    The laser needs 20-30 minutes to heat up and stabilize. NOTICES Wait for the stabilization before starting the calibration or measurement. A not stabilized laser beam can cause false measurement results. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 29: Installation And Starting

    – Pay attention to a shock and impact free transport of the measurement system. NOTICES Dimensions and weights Information regarding dimensions and weights can be found in the Register Technical parame- ters. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 30: Storage

    2.3 Unpacking the system – Before unpacking the system leave it to acclimatize to room temperature. – Let instructed and overview the unpacking by a service employee of the manufacturer. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 31 – Review all components, if they are damaged. – Document all damages and report immediately to the forwarding agent and the manufacturer or the responsi- ble representation (see Register Contacts). ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 32: Place Of Installation

    NOTICES In front of the measurement system had to be at least 1 m space and enough space to the sides for the operator. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 33: Demands For The Computer

    Installation and starting 2.6 Demands for the computer If an own computer is used, it had to clarify with TRIOPTICS or the responsible representation which requirements a computer had to fulfill. 2.7 Necessary external connections Power supply DANGER! Danger to life because of electric shock It can be arise dangers caused by electrical power.
  • Page 34 Only fix the contrast controller on the filter ® wheel of the µPhase 3.3, if the device is fully installed. Remove the contrast controller, if there are no changing of the filters for a longer time. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 35 You find them in the „Mounting instructions“ from SCHNEE- BERGER in the register „Further information.). ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 36 – It is not allowed to block the visual contact by moving on traffic routes, material con- tainer or other obstacles. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 37 1. A first approximate alignment you get with pushing the rails against the screws (Described in 2.8.2 Step 1). 2. Try to parallel align the holder and the rail by visual judg- ment. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 38 If necessary, use a hand bellows to remove dust from the lens. – Position all screws without tighten them. 2. Position the µPhase holder in front of the sample holder. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 39 Only use the delivered connecting cable. On no account use other cables to proved power to ® the µPhase UNIVERSAL. ® The µPhase is provided with power via an USB3 cable connected with the computer. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 40: Software

    NOTICES Limitations for computer not recommended by TRIOPTICS The software is only installed at delivered com- puter. – Contact the support of TRIOPTICS to get to know how to proceed with your own com- puter. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 41 – configure the user interface • open windows • set window options • configure viewing possibilities – load, create and change templates – load and change measurement data ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 42 The log-in dialog appear. Fig. 2-2: Login-Dialog 2. Enter administrator name into the field user name. 3. Enter the administration password into the field pass- word („administrator“, if not changed). ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 43 2. Click on Edit existing. The profile is transferred to the profile input for chang- ing. 3. Changes the profile (name, user level, password). 4. Click on Commit changes. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 44 The log-in data of all created users is filed in an encrypted password file you find under C:\Pro- gramData\TRIOPTICS Berlin. NOTICES It is recommended to store a copy of the modi- fied password file at a safe place. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 45: Operation

    All figures shown in this chapter are from the software version µShape Professional 7 If you use a different software version, the lay- out can be different. Fig. 3-1: Interface of the software µShape ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 46 The direct help opens a list of topics relevant for your searching keyword. 1. Click on the help button in the dialog. The direct help opens a text according to the dialog. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 47: Starting The Measurement System

    1. Start the software with a double click on the mShape icon on the desktop. The software µShape is started automatically. NOTICES You also find the shortcut for the program in the start menu. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 48 The program window is configured according to the cho- sen template. 4. If it not happens already: Select a suitable lens for the test sample and mount it. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 49: Adjustment Of The Sample/ Calibration Normal

    Fig. 3-4: Live view with the window title Intensity The live view (window title: Intensity) shows the current camera picture. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 50 • for a radius measurement rail: shifting along the optical axis of the interferometer (z-axis, for spherical samples) CAUTION! ® Risk of collision between µPhase an d sample while moving along the z axis. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 51 4. Adjust the sample with the help of the x-y-table until a minimal numbers of fringes are visible. If concentric fringes are visible, you have to adjust the sample along the z-axis. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 52: Calibrate The Measurement System

    – the focus was changed. WARNING! Risk of injuries. Risk of injuries caused by fallen device parts. ® – Ensure that the µPhase UNIVERSAL mea- surement system is placed stable. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 53 1. Chose a template suitable for the measurement, if not chosen at the start of the software. If possible, chose one of the delivered templates for the first measurements. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 54 A measurement mask is not necessary. – If you want to set a measurement mask, fol- low the instructions described in Kapitel 3.6 „TSet masks“. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 55 • 80% - for mirrored surfaces • 4% - default setting for uncoated glass surfaces • 1% - for anti reflexion coating • 0,5% - for anti reflexion coating ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 56 Yes. 2. Click on the button Start Measurement to start the repeated measurement. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 57: Measuring A Sample

    C so that M comes to the foreground. WARNING! Risk of injuries. Risk of injuries caused by fallen device parts. ® – Ensure that the µPhase UNIVERSAL mea- surement system is placed stable. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 58 •the scaling (Scaling) If Use... auto scaling is checked for spherical samples, additional enter the radius of the sample under R_Scale. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 59 Kapi- ® tel 2.8.3 „Align the µPhase UNIVERSAL incl. radius measurement rail“, page 15 has to be repeated. To do a radius measurement follow the steps below: ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 60: Set Masks

    If you click on the mask symbol in the program toolbar, the mask drop down toolbar opens with four possibilities: ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 61 Fig. 3-8: mask editor 2. First, choose the underground of the mask by clicking one of the two top icons at the Mask toolbar: opaque (left) or transparent (right); ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 62 – Representation of the measurement results as a three dimensional area with configurable axis and possible sectional view. • 2D Diagram – Data field as a 2D diagram (false color presentation) – Standard results view ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 63 Besides the viewing specific setting (e.g. selection of statistic parameter) Units, the format of numbers and the position of the origin can be changed. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 64 Calculates the ISO parameters according to ISO 10110-5 or ISO 10110-14. • DIN Calculates the DIN parameters according to DIN 3140-5. • Slope Calculates the gradient map (absolute values). ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 65: Save/Load/Export Of Measurement Results

    It would be even better to repeat them. To edit data fields or other parameters with other programs they can be exported in different data formats. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 66 – You have to open the export dialog with <File> <Export Setup> to change settings for the desired parameter export and activate an automatic parameter export after every measurement. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 67: Printing Measurement Results

    This opens a dialog window, where you can change the title, the layout and shown data at the protocol (see Fig. 3-9, 46). In the section Layout main page you can: ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 68 – change the indicated values and their units (Parame- ters) in the text field of the protocol. Click on Change and add or remove parameters (empty lines too) or change the unit under Output format. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 69: Shortcuts

    Full screen mode Shift+F10 Close full screen mode Measurement information (Task Description) Open the input dialog Program mode Change between measurement and calibration mode ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 70: Shut Down The Measurement System

    3.11 Shut down the measurement system 1. Close the µShape software. 2. Shut down the computer. 3. Shut off the monitor and laser and additional devices. 4. Put on all available covers. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 71: Options

    It is possible to measure and analyze for example polishing heads with several samples. Addition- ally it is possible to measure the angle wedge glass with the interferometer (Wedge-Analysis). ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 72 Enables the analyze of toric samples on toric or spherical configurations. Adjustment errors or systematic errors are deducted automatically. If you had purchased an additional add on module, you find additional documentation hereinafter. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 73 Illumination diameter 5 mm 5 mm Measurement area Ø 1 - 5 mm 1 - 5 mm Focusing range 2,25 mm Measurement wavelength 632,8 nm 632,8 nm λ ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 74 Power supply 90 - 264 VAC / 47 - 63 Hz Output voltage at the device 13,5 V power supply Maximal output current ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 75 <0.5 14.5 ± 230 0.24 µLens PLANO 100 130x 277 3.763 <0.6 16.0 ± 900 0.12 µLens PLANO 150 184 x 400 10.558 <0.7 14.0 ± 2000 0.10 ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 76 84.0 x 84.1 0.880 <0.5 0.34 µLens SPHERO 50 f/2.4 84.0 x 79.1 0.790 <0.5 0.21 -102 µLens SPHERO 50 f/4.1 84.0 x 81.1 0.760 <0.5 0.12 -573 ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 77 Technical parameters 1.7 Technical drawings ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 78 Technical parameters ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 79 Customer service representation ................22 Create Support files ....................22 TRIOPTICS service portal..................22 Return parts ....................... 23 Disassembling, disposal and redemption........ 25 Redemption........................ 25 Disposal of components..................... 25 Warranty ..................27 ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 80 ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 81: Maintenance And Repair

    TRIOPTICS or an instructed person. – For unpacking and carrying follow the instructions under “Further information“. – Ensure the stage is position to one side during carrying the rail. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 82: Intervals

    • Updating the software (ask your responsible representa- tion, see Register Contacts) NOTICES – If the mobility of the coarse / fine drive is to slightly, please contact TRIOPTICS or the responsible representation. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 83: Adjust The Laser

    The laser might be defect. 3. Maximize the intensity of the laser by turning the shut- ting screw (b, Fig. 1-2). 4. Test the fiber ending before starting the adjustment. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 84 – Consider the labeling on the fiber and cou- pler plug-in. – You have to put the end marked “FC-AFC“ in the coupler plug-in. – Keep the plug-in and the fiber ends dust- free. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 85 18.Tilt the adjustment plate with one of the three set screws until the maximized intensity in the live view is reached. Repeat this procedure with the other set screws. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 86: Laser Repair

    1.3 Laser repair If you assume an error at your laser, please contact your local partner or use the TRIOPTICS service portal. If you are requested to send back the laser for the repair, follow the steps below: 1. Turn off the laser.
  • Page 87 3. Pay attention to shutting screw at the coupler when posi- tioning the laser (Fig. 1-6). If necessary, the laser can be rotated inside the U-profile holder. Fig. 1-6: Shutting screw under the laser safety cover. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 88: Computer And Software

    During the operation of the system, it is in the area of responsibility of the user to keep the computer safe against viruses. TRIOPTICS provides regular software updates and custom- ized upgrades. For further information ask your responsible representation. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 89: Fuses

    – Only clean the stand superficially. – For suspicion of pollution inside the stand please contact TRIOPTICS or your responsible representation. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 90 – Please contact TRIOPTICS or your responsible represen- tation, if you suspect dust inside the interferometer (see Register Contacts). NOTICES Risk of pollution – Do not touch optical surfaces. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 91: Troubleshooting

    – Only use appropriate lifting tools. WARNING Risk of eye damage Laser radiation – Never look into the beam or his reflection, also not with optical instruments ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 92: Frequently Occurring Error, Causes And Remedy

    – Check the camera settings (integration time, gain). ® – Check the position of the filter wheel at the µPhase 3.3. – Contact TRIOPTICS to ask for a repair. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 93 – Check the environmental influences, avoid vibrations and drafts. – Check the movable mechanics. – If the mechanic is not adjusted properly or defect, con- tact the support of TRIOPTICS. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 94 – Change the filter wheel (only possible with the ® µPhase 3.3). – Check, if the surface reflectivity of the sample is within the specification. – Change the camera gain. – Check the adjustment of the sample. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 95 – Wait for 20 minutes. The laser needs this time to stabi- lize himself. after 20-30 min. the green LED should light up. – If the green LED still flickers after 30 minutes, contact the support of TRIOPTICS. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 96 – Contact the support of TRIOPTICS. Actions to rectify the error: The sealed screws (a) (see Reg- ister Maintenance/Service, – Contact the support of TRIOPTICS to repair the laser. Kapitel 1.2 „Adjust the laser“) were removed ® µPhase...
  • Page 97 – Set the zoom in the live view to 1x and change into the full screen mode with Shift+F10 to minimize the num- ber of fringes. – Contact the support of TRIOPTICS. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 98 • The current camera driver didn‘t allow measurements. Actions to rectify the error: – Check, if the dongle allows measurement (not only ® offline analysis) and install the µPhase camera driver from the µShape installation medium. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 99 • Type of lens is not supported. Actions to rectify the error: – Import the desired lens with <Extras> <Import Objectives>. – If the lens can‘t be imported, contact the support of TRIOPTICS. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 100: Further Information And Direct Help

    There is the possibility to run an error diagnosis by a remote controlled test of you computer through a TRIOPTICS employee. Please contact the support of TRIOPTICS, if you want to do this (see Register Contacts). 2.3 Customer service representation...
  • Page 101: Return Parts

    The maximum size is 5 MB. 5. Click on Submit Service Request to finish. 2.6 Return parts First contact the responsible representation (see Register Contacts) and clarify the modalities. ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 102 Troubleshooting ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 103: Disassembling, Disposal And Redemption

    • Steel and iron • aluminum • non-ferrous metal, e. g. motor windings • Insulation material • cables and wires • electronic scrap • batteries • glass ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 104 ® µPhase UNIVERSAL. Packaging material • Contact a waste management facility. • Wood packaging for the sea transport consist of impreg- nated wood. Pay attention to the regional regulations. ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 105: Warranty

    Warranty 4. Warranty TRIOPTICS grant a one year guaranty for errors of the mate- rial and the manufacture, incipient with the delivery or the installation at the customer facilities (if the installation s per- formed by TRIOPTICS). The guaranty does not apply, if the errors are caused by: •...
  • Page 106 Warranty ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 107 Phone: +1 626 962 5181 69603 Villeurbanne Cedex Fax: +1 626 962 5188 France www.trioptics-usa.com Phone: +33 4 72 44 02 03 Fax: +33 4 72 44 05 06 E-Mail: info@trioptics.fr www.trioptics.fr ® µPhase UNIVERSAL Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.
  • Page 108 # 435, 1st Floor, 6th Avenue, 4th Main, Teachers Colony, Koramangala P.O. Bangalore 560 034 India Phone: +91 80 2552 1990 Fax: +91 80 2552 1991 E-Mail: hpi1@vsnl.net www.hpinstruments.com ® µPhase Manual © 2020 TRIOPTICS Berlin GmbH. All rights reserved.

Table of Contents