Models PHD2220, PHD2350,
PHD2700:
(B) Flow directed to Port "B" Port
"A" returns flow to the reservoir.
WARNING:
Valves do not have a load holding
device. Be sure load is supported
by blocking, mechanical stands or
other appropriate supports before
moving valve lever to the neutral
(N) position.
Air Bleeding:
Loosen oil plug several turns to
allow reservoir venting during
operation.
Position the pump in the
horizontal position at a higher
level than the cylinder.
Put cylinder in horizontal position
with port facing upwards.
6
Air Bleeding (cont):
Advance and retract the cylinder 2
to 3 times to full stroke.
Repeat steps 2 to 4 as needed to
ensure smooth operation of the
cylinder.
Check the oil level of the reservoir
and add oil if necessary. See
section on Maintenance.
2.

MAINTENANCE:

Adding Oil to the Pump:
Check oil regularly and add oil if
required. Refer to procedure below:
Place pump in the horizontal
position on a level surface.
Remove oil fill plug from reservoir
Check oil level (see figure below).
If oil level is low, add additional oil
until level is touching the bottom
on the thread.
Reinstall the oil fil plug into the
reservoir. Ensure the plug is fully
tightened.
Remove air from the system if
necessary and recheck the oil
level.