Springburo CLIPPER Operating Instructions Manual

Springburo CLIPPER Operating Instructions Manual

Test probe

Advertisement

Quick Links

CLIPPER
TEST PROBE
Operating Instructions
Version: 1.3
Clipper Test Probe
EC Declaration of Conformity
The product is marked with this symbol to indicate
that it conforms to the applicable European Union
requirements per Low Voltage Directive LVD
2006/95/EC. Compliance was demonstrated to the
following specification as listed in the Official
journal of the European Communities.
EN 61010-1:2010 Safety requirements for electrical equipment for
measurement, control and laboratory use – Part 031: Safety requirements
for handheld probe assemblies for electrical measurement and test.
EU RoHS Compliance
The Probes and it's accessories conform to the 2011/65/EU RoHS2
Directive, as they have been classified as Industrial Monitoring and Control
Equipment (per Article 3, Paragraph 24).
General Safety Information
Observe generally accepted safety procedures in
addition to those listed here to avoid personal injury or
damage to equipment. The overall safety of any
system incorporating the Clipper Test Probe is the
responsibility of the person using the system.
Because of its application area (the measurement of high voltages), it is
particularly important to read the connection instructions and safety
instructions listed below.
P/N CLP1500V15A1
V1.3
Operating Instructions
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLIPPER and is the answer not in the manual?

Questions and answers

Summary of Contents for Springburo CLIPPER

  • Page 1 The overall safety of any system incorporating the Clipper Test Probe is the responsibility of the person using the system. Because of its application area (the measurement of high voltages), it is particularly important to read the connection instructions and safety instructions listed below.
  • Page 2 The Clipper is designed for Laboratory use only. Do not use in wet or Connect & Disconnect Properly: explosive atmosphere. The Clipper Test Probe has an “IN” and an “OUT” connection. The “IN” is to Cleaning: be connected across the Vds or the Vce of the DUT (Device Under Test).
  • Page 3 Applications possibilities. The Clipper is perfect for observing the Rds(on) of a switched FET, or IGBT. With an Oscilloscope set to 200mV /division, the stability of Rds(on) over a range of say 200mΩ to 1Ω can be clearly seen in good resolution, while the power transistor is switching.
  • Page 4 Oscilloscope probe. It is recommended to use a 10X high impedance effects such as ringing. probe. This is because as the Clipper is a passive device (no external power supply required) there is no active impedance buffering in the device. To protect the device, a series 300Ω...
  • Page 5 International Patent (pending at time of writing, July 2014). Recycling: The Clipper can be recycled with the normal electronic recycling systems. There are no hazardous materials included (such as batteries or Lead). Springburo GmbH is registered with the ear-stiftung in Germany, which regulates the recycling of consumer and Industry electronic products.
  • Page 6 Clipper Test Probe Operating Instructions Clipper Test Probe Operating Instructions DISTRIBUTORS Manufacturer: Springburo GmbH The product is supported by trained field technicians in the following Theodor-Ludwig-Strasse 24 regions: D-79312 Emmendingen Germany Germany: Tel: +49 7641 953 83-0 ADMESS Elektronik GmbH www.springburo.org...

This manual is also suitable for:

Clp1500v15a1

Table of Contents