Eaton Compressor 5HP Manual

Eaton Compressor 5HP Manual

Inline pump

Advertisement

Quick Links

5HP INLINE PUMP MANUAL
REV030921
APP2I0524TP

Advertisement

Table of Contents
loading

Summary of Contents for Eaton Compressor 5HP

  • Page 1 5HP INLINE PUMP MANUAL REV030921 APP2I0524TP...
  • Page 2: Table Of Contents

    5HP INLINE PUMP MANUAL REV030921 Contents Safety Information Breathable Air Area Piping Installation Operation Maintenance Pump Explosion/Part List 9-18 Troubleshooting Warranty Statement 20-21...
  • Page 3: Safety Information

    5HP INLINE PUMP MANUAL REV030921 SAFTEY INFORMATION This manual contains very important information to know and understand. This is to provide for SAFTEY and to PREVENT EQUIPMENT PROBLEMS. To help understand this information, observe the following: DANGER: Danger indicates and imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 4: Area

    5HP INLINE PUMP MANUAL REV030921 Personal Protective Equipment Be sure all Be sure all operators and others around the pump and its controls comply with all applicable OSHA, Federal, State and Local regulations, codes, and standards relating to personal protective equipment. This includes respiratory protective equipment, protection for the extremities, protective clothing, protective shields and barriers, electrical protective equipment, and personal hearing protective equipment.
  • Page 5: Installation

    5HP INLINE PUMP MANUAL REV030921 5. Never use reducers in discharge piping. Keep all piping and fittings the same size I the piping system. 6. Minimum pipe size for compressed air lines: (Pipe sizes are shown in inches) 25ft 50ft...
  • Page 6 5HP INLINE PUMP MANUAL REV030921 2. Connect main feed line to check valve. Pump MUST have a check valve installed inline to tank. This helps to prevent the pump from starting underload. This also prevents air loss and premature pump wear. Minimum line ID size for main line is 5/8”.
  • Page 7: Operation

    5HP INLINE PUMP MANUAL REV030921 WARNING: Always make sure main power is off prior to touching belts or other moving parts of the pump. Operation 1. The unit is shipped with pump break-in oil and should be ready to operate. Be sure to check for proper oil level before running.
  • Page 8: Maintenance

    5HP INLINE PUMP MANUAL REV030921 Maintenance 1. Make sure repairs and service are done in a clean, dry, well-lit, and well-ventilated area. 2. When cleaning/blowing off, DO NOT exceed 30 PSI (2.1 bar) of pressure. NEVER use solvents for cleaning purposes.
  • Page 9 5HP INLINE PUMP MANUAL REV030921 5. How to change pump oil: To drain oil: 1. Remove the oil fill cap. 2. Open Oil drain valve and allow oil to drain naturally from pump. 3. Remove oil filter and clean with a mild solvent.
  • Page 10: Pump Explosion/Part List

    5HP INLINE PUMP MANUAL REV030921 Pump Explosion/Parts List...
  • Page 11 5HP INLINE PUMP MANUAL REV030921...
  • Page 12 5HP INLINE PUMP MANUAL REV030921...
  • Page 13 5HP INLINE PUMP MANUAL REV030921...
  • Page 14 5HP INLINE PUMP MANUAL REV030921...
  • Page 15 5HP INLINE PUMP MANUAL REV030921...
  • Page 16 5HP INLINE PUMP MANUAL REV030921...
  • Page 17 5HP INLINE PUMP MANUAL REV030921...
  • Page 18 5HP INLINE PUMP MANUAL REV030921...
  • Page 19 5HP INLINE PUMP MANUAL REV030921...
  • Page 20: Troubleshooting

    5HP INLINE PUMP MANUAL REV030921 Troubleshooting Some pump issues can be fixed simply by verifying the following guide. It is advised to go through the guide prior to calling technical support to help expedite the assistance process. Issue Action Pump does not run Check unit power supply.
  • Page 21: Warranty Statement

    5HP INLINE PUMP MANUAL REV030921 Warranty Statement • Standard Warranty: That each compressor bare pump is free from defects in material, workmanship, and parts for *1 year from the date of delivery. Manufacturer is not responsible for downtime during warranty service. If downtime is necessary, it is at the owner’s discretion, obligation, and expense, to have a redundant compressor.
  • Page 22 5HP INLINE PUMP MANUAL REV030921 environments where fine dust is common, such as granite, marble or concrete plants, the pump MUST be installed in a separate area with its own dedicated ventilation. FAILURE TO PROVIDE THIS DUST FREE OPERATING AREA VOIDS THE WARRANTY.

This manual is also suitable for:

App2i0524tp

Table of Contents