Applications & Features
High accuracy digital sensor, field changeable
without any re-calibration
Large, high light LED display
Multiple inputs and outputs selection
Light and up-to-date enclosure
Single point temperature, humidity or DP
measurement and display
Multiple points temperature, humidity and DP
measurement, display and network data
collection
Compatible to DDC and PLC systems
Specifications
Application
Founction
Power
Consumption
Display
Display Resolution
Display Range
Display Accuracy
Response Time
Sensor
Standard Input
Standard Output
Communication
Dimension
W715*H285*D50mm
Weight
Material
Protection
Installation
Buttons &
Three buttons with parameters calibration, buzzer/relay parameters set, RS485 address set,
Functions
input signals/ranges set, output ranges set, LED inspection, restore default set, etc
Models
All products are factory set to 4-20mA as output default, and can be set to 0-10V by jumper
on the PCB
THD
Clean room, library, museum, lab, etc.
Single point or multiple points network data measurement and display
<15W
0.1° C,0.1%RH
0~50.0° C,0~99.9%RH
<
±
0.5° C @5-50° C
<
±
3%RH@20-80%RH, 25° C
Temp. 30s, Hum.10s
THD-S T/RH sensor
2×0-10V/4-20mA(2-10V)
2×0-10V/4-20mA
RS485/Modbus RTU, 9600-n-8-1, support read/output and write/input parameters
W470*H520*D50mm
3.8kg
Dull silver color aluminum alloy frame, PC panel with PVC film
THDV
THD
Model
THDV
THPD
0
1
Input
8
Output
Relay
THDV
85~265VAC
3 Bit 4 inch red LED
1%FS
4.2kg
IP30
Wall mount or suspend from ceiling
THPD
Temp/Hum Display Screen
Temp/Hum Display Screen(Vertical)
Temp/Hum /DP Display Screen
Remote sensor, 1.5m cable
0-10V/4-20mA input, without sensor
RS485/Modbus RTU input, without
sensor
0
without any output
1
0-10V/4-20mA
8
RS485,Modbus RTU
B
0-10V/4-20mA, RS485/Modbus RTU
0 N/A
1 1×SPDT+ inside buzzer
THPD
Clean room, lab, etc.
<15W
0.1° C,0.1%RH,0.1Pa
0~50.0° C,0~99.9%RH,0~99.9Pa
<±0.5° C @5~50° C
<±3%RH@20~80%RH, 25° C
<±1Pa @0~99.9Pa, 25° C
Temp. 30s, Hum. 10s, DP 5s
THD-S T/RH sensor, DPT DP transmitter
3×0-10V/4-20mA(2-10V)
3×0-10V/4-20mA
W470*H650*D50mm
5.2kg
Edition:B/3
(Horizontal)
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the THD and is the answer not in the manual?

Questions and answers

Summary of Contents for TEREN THD

  • Page 1 THD/THDV/THPD Display Screen For Temp./ Humidity / Diff. Pressure Edition:B/3 THD/THDV/THPD Display Screen For Temp./ Humidity / Diff. Pressure THDV THPD Applications & Features Models Temp/Hum Display Screen (Horizontal) High accuracy digital sensor, field changeable  Model THDV Temp/Hum Display Screen(Vertical)
  • Page 2 AIN3 with power supply connected to EXC+ (+24V) and the jumper of J13setted to mA position. 4. External universal input signal (default 4~20mA) External universal input signals use AIN1/2 for THD/THDV and AIN1/2/3 for THPD respectively, J11/12/13 should be at the...
  • Page 3 6. External universal output signal (default 4~20mA) External universal output signals use OUT1/2 for THD/THDV and OUT1/2/3 for THPD respectively, J1/2/3 should be at the mA position for 4-20mA signals and at the Vo position for 0-10V signals.
  • Page 4 THD/THDV/THPD Display Screen For Temp./ Humidity / Diff. Pressure Edition:B/3 (2)."P485": RS485 address set (default 1, range 1~255, suggested range1~32) ●→▲/▼→485→●→▲/▼→XXX→● “XXX” means setting parameter. (3)."P111": Chanel 1 input set ●→▲/▼→111→●→▲/▼→XXX* →●→▲/▼→XXX* →●→▲/▼→XXX* →●→▲/▼→ XXX* →●→▲/▼→XXX* →● “XXX” means: *1: Input mode( 0=matched sensor, 1=universal analog input 0-10V, 2= Modbus input, 3=universal analog input 4-20mA,);...
  • Page 5 THD/THDV/THPD Display Screen For Temp./ Humidity / Diff. Pressure Edition:B/3 ●→▲/▼→811→●→▲/▼→XXX→● “XXX” means setting parameter. 0:500mS,1:1S,2:1.5S,3:2S,4:2.5S,5:3S,6:3.5S,7:4S,8:4.5S,9:5S. (23)."P811": Chanel 2 response time set(default 0, range 0-9) ●→▲/▼→811→●→▲/▼→XXX→● Refer P811 (24)."P811": Chanel 3 response time set(default 0, range 0-9) ●→▲/▼→811→●→▲/▼→XXX→● Refer P811...
  • Page 6: Rs485- Modbus Rtu

    THD/THDV/THPD Display Screen For Temp./ Humidity / Diff. Pressure Edition:B/3 40056 Chanel 3 buzzer alarm Refer channel 1 40057 Chanel 3 buzzer low limit Refer channel 1 40058 Chanel 3 buzzer high limit Refer channel 1 40059 Chanel 3 input type...
  • Page 7 THD/THDV/THPD Display Screen For Temp./ Humidity / Diff. Pressure Edition:B/3 03H Read Holding Registers Sample: Read device(ID=5)registers 00000-00001 Set as shown right. Slave address:5 Function: 03 Register started address: 0 Register reading length:2 Scan rate:1000 ms Communication codes: Master / PC to SLAVE: 05 03 00 00 00 02 C5 8F SLAVE to Master / PC:...

This manual is also suitable for:

ThdvThpd